R2E133-BH66-24 ebm-papst 230VAC 133mm AC Centrifugal Fan

$974.00

ebm-papst R2E133-BH66-24 (R2E133BH6624) 230VAC Ø133mm AC centrifugal fan, 2700/3200RPM, 140/165CFM, 25/28W, with PA6 impeller, AMP connector & IP44.

SKU: R2E133-BH66-24 Category: Brand:

Description

ebm-papst R2E133-BH66-24 (also known as R2E133BH6624, OEM Item No. 11101-5-9980) is an unhoused backward-curved AC centrifugal motorized impeller powered by an external-rotor M2E052-BF motor with a 133 mm (5.24 in) outer diameter and 60.6 mm (2.39 in) total axial depth. Operating on single-phase 230 VAC (50/60 Hz) power, it delivers 2700 RPM (50 Hz) / 3200 RPM (60 Hz) at 25 W / 28 W (0.11 A / 0.13 A) and generates a maximum free-air flow of 140 CFM (240 m³/h) at 50 Hz or 165 CFM (280 m³/h) at 60 Hz.

Built with a 7-blade glass-fiber reinforced PA6 composite impeller and precision ball bearings, this IP44-rated impeller comes pre-configured with an adhesive-backed run capacitor (1.0 µF / 400 VDB) and a 200 mm (7.87 in) harness terminated with an AMP 350766-4 plug housing and AMP 160389-3 PE receptacle.

Key Features

  • Dual-Frequency Aerodynamic Output: Delivers 140 CFM (240 m³/h) at 2700 RPM (50 Hz) and 165 CFM (280 m³/h) at 3200 RPM (60 Hz).
  • High Static Pressure Capability: Backward-curved 7-blade geometry overcomes system resistance up to 190 Pa (50 Hz) and 255 Pa (60 Hz).
  • Reinforced PA6 Impeller: Molded from glass-fiber reinforced PA6 polyamide plastic for dimensional stability and corrosion resistance.
  • Pre-Wired AMP Connector & Capacitor: Includes an adhesive-foil 1.0 µF capacitor, AMP 350766-4 plug housing, and AMP 160389-3 PE receptacle.
  • Thermal & Ingress Protection: Protected to IP44 with Class B insulation, ball bearings, and an internally connected thermal overload protector (TOP).
  • Global Safety Certifications: Approved to UL 2111, CSA C22.2 No. 77, VDE, CCC, and CE (EN 60335-1) for international OEM integration.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) R2E133-BH66-24
Alternate Part Number R2E133BH6624
OEM Item Number 11101-5-9980
Integrated Motor Model M2E052-BF
Product Series R2E133 Series
Product Category AC Centrifugal Fans
Fan / Component Type Backward-Curved Motorized Impeller (Unhoused)
Motor Design / Technology Single-Phase External-Rotor AC Capacitor Motor
Phase & Supply Type 1~ (Single-Phase AC)
Rated Voltage 230 VAC
Frequency 50 / 60 Hz
Free-Air Speed (RPM) 2700 RPM (50 Hz) / 3200 RPM (60 Hz)
Speed (Max. Load) 2695 RPM (50 Hz at 100 Pa) / 3125 RPM (60 Hz at 140 Pa)
Free-Air Power Input 25 W (50 Hz) / 28 W (60 Hz)
Max. Input Power 26 W (50 Hz at 100 Pa) / 29 W (60 Hz at 70–180 Pa)
Free-Air Current Draw 0.11 A (50 Hz) / 0.13 A (60 Hz)
Inrush / Starting Current 0.20 A (50 Hz) / 0.21 A (60 Hz)
Run Capacitor 1.0 µF, 400 VDB (Class S0 per EN 60252-1, Included with Adhesive Foil)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 140 CFM / 240 m³/h (50 Hz at 0 Pa) | 165 CFM / 280 m³/h (60 Hz at 0 Pa)
Operating Duty Point 2 (Curve) 120 CFM / 205 m³/h at 0.20 in H₂O / 50 Pa (50 Hz, 2700 RPM, 25 W) | 140 CFM / 235 m³/h at 0.28 in H₂O / 70 Pa (60 Hz, 3130 RPM, 29 W)
Operating Duty Point 3 (Curve) 90 CFM / 150 m³/h at 0.40 in H₂O / 100 Pa (50 Hz, 2695 RPM, 26 W) | 100 CFM / 170 m³/h at 0.56 in H₂O / 140 Pa (60 Hz, 3125 RPM, 29 W)
Operating Duty Point 4 (Curve) 45 CFM / 80 m³/h at 0.56 in H₂O / 140 Pa (50 Hz, 2730 RPM, 25 W) | 65 CFM / 115 m³/h at 0.72 in H₂O / 180 Pa (60 Hz, 3165 RPM, 29 W)
Max. Tested Curve Pressure 0.56 in H₂O / 140 Pa (50 Hz) | 0.72 in H₂O / 180 Pa (60 Hz)
Max. Static Pressure (Chart Shutoff) 0.76 in H₂O / 190 Pa (50 Hz) | 1.02 in H₂O / 255 Pa (60 Hz)
Min. Back Pressure 0 Pa (0 in H₂O)
Aerodynamic Measurement Standard ISO 5801 Installation Category A (LU-53691-1 at 50 Hz / LU-53692-1 at 60 Hz)
Ingress Protection (IP) IP44 (Installation- and Position-Dependent)
Moisture / Environmental Class F0
Operating Temperature -25 °C to +55 °C (-13 °F to +131 °F) at 50 Hz | -25 °C to +65 °C (-13 °F to +149 °F) at 60 Hz
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Motor & Drive Protection Thermal Overload Protector (TOP) Internally Connected
Electrical Protection Class Class I (With Customer Connection of Protective Earth)
Touch Current (IEC 60990) < 0.75 mA (Measuring Circuit Fig. 4, TN System)
Insulation Class Class B
Termination Type Pre-Wired AMP Connector Housing & Pre-Connected Run Capacitor
Connector Housing & Terminal Specs AMP 350766-4 Housing with 2x Plug Pin AMP 350538-1, 1x Plug Pin AMP 926885-1 & PE Flat Push-On Receptacle AMP 160389-3
Cable Exit Orientation Variable Cable Exit
Cable / Lead Length 200 ±20 mm (7.87 ±0.79 in)
Wiring Pinout / Connection U1 (Pin 4.1) = Blue (Line), Z (Pin 4.2) = Brown (+ Capacitor), U2 (Pin 4.3) = Black (Neutral + Capacitor), PE = Green/Yellow (AMP 160389-3)
Impeller Size Ø 133 mm (5.24 in)
Outer Dimensions (Ø × D) Ø 133 × 60.6 mm (Ø 5.24 × 2.39 in)
Impeller Section Width 35 mm (1.38 in)
Rotor / Hub Diameter Ø 73 ±1 mm (2.87 in)
Mounting Hole Pitch Ø 58 mm (2.28 in) Bolt Circle
Mounting Hole Diameter / Thread Size 4 × M4 Threaded Holes
Max. Screw Clearance 5 mm (0.20 in)
Weight 0.7 kg (1.54 lbs)
Blade Count & Geometry 7 Backward-Curved Blades
Bearing Type Ball Bearing
Impeller / Blade Material Glass-Fiber Reinforced PA6 Plastic
Direction of Rotation Clockwise (Viewed Toward Rotor)
Installation Position Any
Condensation Drainage Holes None
Compatible Inlet Ring (Optional) 09566-2-4013 (Not Included in Scope of Delivery)
Standards & Compliance CE, EN 60335-1, UL 2111, CSA C22.2 No. 77, VDE, CCC

Applications

ebm-papst R2E133-BH66-24 unhoused backward-curved centrifugal fans are engineered for pressurized plenum and ducted cooling architectures where compact axial depth and plug-and-play harness integration are essential. They are widely deployed in power electronics enclosures, variable frequency drives (VFDs), telecom base station rectifiers, medical diagnostic equipment, laboratory extraction hoods, and compact heat recovery ventilation (HRV) units. Because backward-curved blades operate efficiently without a scroll housing, this motorized impeller serves as a direct drop-in OEM replacement for densely packed automation cabinets and industrial thermal management modules.