Description
ebm-papst R2D280-RB06-01 (also known as R2D280RB0601) is a high-efficiency 280 mm (11.02 in) single-intake backward-curved AC motorized centrifugal impeller engineered on the aerodynamic RadiCal platform. Driven by a robust three-phase external rotor M2D074-GA motor, this industrial fan delivers up to 1,735 CFM (2,950 m³/h) of free-air flow and generates up to 2.61 in H₂O (650 Pa) of static pressure under max load conditions. Construction highlights include an aerodynamically optimized 6-blade polypropylene (PP) plastic impeller, precision maintenance-free ball bearings, black-painted rotor finish, and rotor-side condensation drainage holes. Rated for continuous S1 duty across dual-voltage 230 VAC (Delta) and 400 VAC (Star) 50 Hz configurations, the unit features built-in thermal overload protection (TOP) with basic insulation, IP44 environmental sealing, and a pre-stripped 9-wire PFA harness.
Key Features
- RadiCal Impeller Aerodynamics: 6-blade backward-curved PP plastic impeller optimizes airflow efficiency while drastically reducing operating noise.
- Dual-Voltage Three-Phase Motor: Integrated M2D074-GA motor supports 230 VAC Delta and 400 VAC Star 50 Hz power networks.
- High Static Pressure Performance: Delivers up to 1,735 CFM and overcomes system resistance up to 650 Pa (2.61 in wg).
- Robust Bearing System: Premium dual ball bearings ensure smooth continuous S1 operation in horizontal or shaft-down orientations.
- Integrated Thermal Protection: Factory-wired thermal overload protector (TOP) protects motor windings against operational overtemperature faults.
- Industrial Environmental Ingress: IP44 enclosure rating with rotor-side drainage slots and Class F insulation rated to +80 °C storage.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | R2D280-RB06-01 |
| Alternate Part Number | R2D280RB0601 |
| Integrated Motor Model | M2D074-GA |
| Product Series | RadiCal |
| Product Category | AC Centrifugal Fans |
| Fan / Component Type | Motorized Impeller (Backward-Curved Centrifugal) |
| Motor Design / Technology | External rotor 3-phase AC motor |
| Phase & Supply Type | 3-Phase AC |
| Rated Voltage | 230 / 400 VAC (Δ / Y) |
| Wiring Configuration | Delta (Δ) for 230 VAC / Star (Y) for 400 VAC |
| Frequency | 50 Hz |
| Speed (RPM) | 2500 RPM (at max load) / 2640 RPM (free air) |
| Power Rating | 570 W (Nominal Max Load) / 440 W (Free Air) |
| Rated Current | 1.58 A (at 230 VAC Δ) / 0.91 A (at 400 VAC Y) |
| Starting Current | 4.36 A (at 230 VAC Δ) / 2.52 A (at 400 VAC Y) |
| Airflow (Max. Free-Air) | 1735 CFM (2950 m³/h) |
| Operating Duty Point Airflow | 1470 CFM @ 250 Pa / 1110 CFM @ 500 Pa / 765 CFM @ 650 Pa |
| Max. Static Back Pressure | 2.61 in H₂O (650 Pa) |
| Min. Back Pressure | 0 in H₂O (0 Pa) |
| Sound Pressure Level | 66 to 76 dB(A) (intake side, 1 m distance) |
| Sound Power Level | 73 to 84 dB(A) (intake side) |
| Impeller Size | Ø 280 mm (11.02 in) |
| Motor Size | 74 |
| Blade Count & Geometry | 6 backward-curved blades |
| Impeller Material | PP plastic (Polypropylene) |
| Rotor Surface | Painted black |
| Bearing Type | Precision Ball Bearing |
| Direction of Rotation | Clockwise, viewed toward rotor |
| Installation Position | Shaft horizontal or rotor on bottom (rotor on top on request) |
| Condensation Drainage Holes | On rotor side |
| Operating Mode / Duty Cycle | S1 (Continuous operation) |
| Weight | 5.4 kg (11.90 lbs) |
| Termination Type | Cable with crimped splices |
| Lead Wire Gauge & Spec | PFA 9G 0.5 mm² (9 conductors with crimped splices) |
| Wiring Pinout / Connection | U1/L1=Black, V1/L2=Blue, W1/L3=Brown, U2=Green, V2=White, W2=Yellow, TOP=2x Gray, PE=Green/Yellow |
| Motor Protection | Thermal overload protector (TOP) with basic insulation |
| Electrical Protection Class | Class I (with protective earth connected) |
| Touch Current (IEC 60990) | < 0.75 mA (TN system, measuring circuit Fig. 4) |
| Insulation Class | Class F |
| Ingress Protection (IP) | IP44 (installation- and position-dependent per EN 60034-5) |
| Moisture / Environmental Class | H1 |
| Operating Temperature | -25 °C to +50 °C (-13 °F to +122 °F) |
| Storage Temperature | -40 °C to +80 °C (-40 °F to +176 °F) |
| Mounting Screw Depth | Max. clearance for screw 10 mm |
| Compatible Inlet Ring | 28000-2-4013 (accessory, not included) |
| Standards & Compliance | EN 60335-1, EAC |
Applications
ebm-papst R2D280-RB06-01 motorized impellers provide dedicated forced convection cooling and ventilation across mission-critical industrial electrical equipment and HVAC infrastructure. Commonly deployed within modular air handling units (AHUs), commercial heat recovery ventilation (HRV) systems, and data center precision air conditioning (CRAC/CRAH) plenums, this centrifugal fan efficiently overcomes restricted airflow paths. It is also an industry-standard component for high-power variable frequency drive (VFD) enclosures, solar inverter cabinets, uninterruptible power supply (UPS) modules, and central telecom power plant systems requiring high static pressure capability.