K2E225-RB92-09 ebm-papst 230VAC 225mm AC Centrifugal Fan

$463.00

ebm-papst K2E225-RB92-09 (K2E225RB9209) 230VAC 225mm AC centrifugal fan, 2550/2700RPM, 525/555CFM, 145/200W, with mounting bracket, M2E068-DF motor & IP44.

SKU: K2E225-RB92-09 Category: Brand:

Description

ebm-papst K2E225-RB92-09 (also known as K2E225RB9209) is a backward-curved AC centrifugal fan assembly featuring an integrated housing and galvanized sheet-steel mounting bracket built around the M2E068-DF external rotor motor and a 225 mm (8.86 in) 7-blade polyamide (PA) impeller. Operating on single-phase 230 VAC at 50/60 Hz, it delivers a free-air flow of 525 CFM (890 m³/h) at 2550 RPM (145 W, 0.64 A at 50 Hz) and 555 CFM (945 m³/h) at 2700 RPM (200 W CE / 215 W UL, 0.88 A CE / 0.95 A UL at 60 Hz), with an ErP optimum static efficiency point of 414.95 CFM (705 m³/h) at 1.286 in H₂O (320 Pa).

Engineered for continuous S1 industrial duty from -25 °C to +60 °C (-13 °F to +140 °F), the unit incorporates a pre-mounted 3.5 µF / 450 VDB safety capacitor, maintenance-free ball bearings, an internally connected thermal overload protector (TOP), and an IP44 / Class F / H1 moisture-resistant enclosure with a PFA AWG20 lead cable.

Key Features

  • Dual-Frequency Aerodynamic Output: Delivers 525 CFM (890 m³/h) at 50 Hz and 555 CFM (945 m³/h) at 60 Hz free air.
  • Pre-Mounted Capacitor & Bracket Housing: Combines a PA plastic and galvanized steel bracket housing with an integrated 3.5 µF / 450 VDB run capacitor.
  • Backward-Curved Impeller Efficiency: 7-blade Ø225 mm PA plastic impeller achieves 42.5% ErP static efficiency (Grade N 62) without a scroll volute.
  • Integrated Thermal & Ingress Protection: Internal thermal overload protector (TOP), IP44 rating, Class F insulation, and H1 environmental protection ensure operational safety.
  • High-Temperature PFA AWG20 Cabling: Pre-wired with a 2-conductor PFA-insulated AWG20 power lead (blue Line, black Neutral) for rapid OEM integration.
  • Multi-Standard Global Certifications: Fully approved to CE, EN 60335-1, UL 507, CSA C22.2 No. 113, CCC, and EAC industrial standards.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) K2E225-RB92-09
Alternate Part Number K2E225RB9209
OEM Item Number 12636-5-9980
Integrated Motor Model M2E068-DF (Motor Size 68)
Product Series K2E225
Product Category AC Centrifugal Fans
Fan / Component Type Backward-Curved AC Centrifugal Fan with Housing and Mounting Bracket
Motor Design / Technology AC External Rotor Capacitor-Run Induction Motor
Phase & Supply Type 1~ (Single-Phase AC)
Rated Voltage 230 VAC
Frequency 50 / 60 Hz
Speed (Max. Load) 2550 RPM (50 Hz) / 2700 RPM (60 Hz)
Free-Air Speed (RPM) 2550 RPM (50 Hz) / 2700 RPM (60 Hz)
ErP Optimum Speed (RPM) 2560 RPM (at 50 Hz Optimum Efficiency)
Power Rating (Max. Load) 145 W (50 Hz CE) / 200 W (60 Hz CE)
Power Rating (UL 507 60 Hz) 215 W (at 230 VAC, 60 Hz UL 507)
Free-Air Power Input 145 W (50 Hz) / 200 W (60 Hz)
ErP Optimum Efficiency Power 140 W / 0.14 kW (at 50 Hz Optimum Efficiency)
Rated Current (Max. Load) 0.64 A (50 Hz CE) / 0.88 A (60 Hz CE)
Rated Current (UL 507 60 Hz) 0.95 A (at 230 VAC, 60 Hz UL 507)
Free-Air Current Draw 0.64 A (50 Hz) / 0.88 A (60 Hz)
Inrush / Starting Current 1.25 A (50 Hz) / 1.20 A (60 Hz)
Run Capacitor 3.5 µF, 450 VDB (Safety Class S2 per EN 60252-1 / UL)
Capacitor Wiring / Operation Mode Capacitor pre-mounted on fan assembly
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 525 CFM / 890 m³/h (50 Hz) / 555 CFM / 945 m³/h (60 Hz) at 0 Pa (0.00 in H₂O)
ErP Optimum Efficiency Duty Point 414.95 CFM (705 m³/h) at 1.286 in H₂O (320 Pa)
Max. Static Pressure (Chart Curve) 2.41 in H₂O / 600 Pa (50 Hz) / 3.41 in H₂O / 850 Pa (60 Hz)
Min. Back Pressure 0 Pa (0.00 in H₂O)
ErP Efficiency & Grade (EU 327/2011) Overall Static Efficiency ηes = 42.5%, Efficiency Grade N = 62, Measurement Category A, Specific Ratio = 1.00, No VSD (Test LU-127147)
Airflow Measurement Standard ISO 5801 Installation Category A (50 Hz Test LU-140928-1 / 60 Hz Test LU-140931-1 at ρ = 1.2 kg/m³)
Ingress Protection (IP) IP44 (Installation- and position-dependent per EN 60034-5)
Moisture / Environmental Class H1
Operating Temperature -25 °C to +60 °C (-13 °F to +140 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Motor & Drive Protection Thermal Overload Protector (TOP) internally connected
Touch Current (IEC 60990) < 0.75 mA (Measuring circuit Fig. 4, TN system)
Insulation Class Class “F”
Termination Type Pre-wired power cable with capacitor mounted
Lead Wire Gauge & Spec PFA-insulated cable, AWG20 (2 conductors)
Wiring Pinout / Connection L (Line) = Blue (Wire 1.1), N (Neutral) = Black (Wire 1.2)
Impeller Size Ø 225 mm (8.86 in)
Weight 4.1 kg (9.04 lbs)
Blade Count & Geometry 7 Backward-Curved Blades
Bearing Type Ball Bearing
Housing / Scroll / Frame Material PA Plastic and Galvanized Sheet Steel (Housing and Mounting Bracket)
Impeller / Blade Material PA Plastic (Polyamide)
Rotor Surface Painted black
Direction of Rotation Clockwise, viewed toward rotor
Installation Position Shaft horizontal or rotor on bottom (rotor on top available on request)
Condensation Drainage Holes On rotor side
Standards & Compliance CE, EN 60335-1, UL 507, CSA C22.2 No. 113, CCC, EAC

Applications

ebm-papst K2E225-RB92-09 backward-curved centrifugal fan with integrated housing and mounting bracket is engineered for high-back-pressure air movement in compact OEM machinery and enclosure thermal management systems. Typical deployments include power electronics and variable frequency drive (VFD) cabinets, commercial refrigeration condensers, heat recovery ventilation (HRV) plenums, medical and laboratory extraction equipment, and industrial automation control enclosures. Its unitized bracket and pre-mounted run capacitor simplify drop-in MRO replacement and production assembly in ducted or pressurized plenums requiring reliable radial airflow against elevated system impedance.