Description
ebm-papst A3G800-AU25-05 (also known as A3G800AU2505) is an industrial 800 mm (31.50 in) S-series HyBlade EC axial fan powered by an integrated M3G150-IF electronically commutated motor. Operating across a 3-phase 380–480 VAC (400 VAC nominal) 50/60 Hz supply, it delivers a maximum free-air flow of 15,655 CFM (26,600 m³/h) at 1020 RPM and up to 0.92 in H₂O (230 Pa) static pressure at maximum load (2560 W, 3.9 A). Built with 5 aerodynamically optimized sickle-shaped blades featuring a sheet aluminum insert sprayed with PP plastic and a black-painted die-cast aluminum electronics housing, this unit provides quiet, high-efficiency airflow in “V” direction. It features ball bearings, IP55 and F4-1 environmental protection, an integrated PID controller, RS-485 MODBUS-RTU, and 0–10 VDC/PWM control via a SELV-isolated terminal box.
Key Features
- High-Volume EC Aerodynamics: Delivers 15,655 CFM (26,600 m³/h) free-air output and up to 0.92 in H₂O (230 Pa) back pressure at 1020 RPM.
- Hybrid HyBlade Impeller Design: Five 0°-pitch sickle-shaped blades combine a rigid sheet aluminum insert with PP plastic overmolding for low acoustic emissions.
- Integrated M3G150-IF EC Drive: Three-phase 380–480 VAC 50/60 Hz motor achieves 44.2% static efficiency (ErP Grade N 48.4) with passive PFC.
- Advanced Control & Telemetry: Equipped with RS-485 MODBUS-RTU, integrated PID controller, 0–10 VDC/PWM and 4–20 mA inputs, plus floating alarm relay.
- Comprehensive Motor Protection: Includes thermal overload protection, line undervoltage and phase failure detection, soft start, motor current limitation, and locked-rotor protection.
- Industrial IP55 Construction: Features a black-painted die-cast aluminum electronics enclosure, Class F insulation, F4-1 moisture rating, and rotor-side condensation drainage holes.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | A3G800-AU25-05 |
| Alternate Part Number | A3G800AU2505 |
| OEM Item Number | 51559-5-9980 |
| Integrated Motor Model | M3G150-IF |
| Product Series | HyBlade S Series (Sickle-Shaped Blades) |
| Product Category | EC Axial Fans |
| Fan / Component Type | EC Axial Fan (Motor-Impeller Assembly) |
| Motor Design / Technology | External Rotor Electronically Commutated (EC) Motor with Integrated Electronics |
| Phase & Supply Type | 3-Phase (3~) |
| Rated Voltage | 400 VAC |
| Operating Voltage Range | 380 to 480 VAC |
| Frequency | 50 / 60 Hz |
| Speed (RPM) | 1020 RPM |
| Max. Input Power | 2560 W (at Max. Load / 230 Pa); 1586 W (at Free Air / 0 Pa) |
| ErP Optimum Input Power | 2210 W (2.21 kW) |
| Max. Current Draw | 3.90 A (at Max. Load / 230 Pa); 2.74 A (at Free Air / 0 Pa) |
| Airflow (Max. Free Air) | 15,655 CFM (26,600 m³/h) at 0 Pa |
| Operating Duty Point Airflow | 13,695 CFM (23,270 m³/h) at 80 Pa; 11,415 CFM (19,390 m³/h) at 160 Pa; 8,785 CFM (14,930 m³/h) at 230 Pa |
| ErP Optimum Duty Point | 10,321 CFM (17,535 m³/h) at 0.76 in H₂O (189 Pa) |
| Max. Static Pressure | 0.92 in H₂O (230 Pa) at 1020 RPM |
| Sound Pressure Level (Intake) | 68 dB(A) at 0 Pa; 67 dB(A) at 80 Pa; 69 dB(A) at 160 Pa; 74 dB(A) at 230 Pa (at 1 m) |
| Sound Power Level (Intake / Outlet) | 75 / 75 dB(A) at 0 Pa; 81 / 80 dB(A) at 230 Pa |
| Static Efficiency (ErP ηes / Grade N) | 44.2% (ErP Efficiency Grade N = 48.4) |
| Airflow Direction | “V” (Axial Intake Over Rotor, Discharge Over Stator) |
| Direction of Rotation | Clockwise, Viewed Toward Rotor |
| Nominal Fan Size | 800 mm (31.50 in) |
| Impeller Outer Diameter | Ø 788 ±2 mm (31.02 in) |
| Rotor Diameter | Ø 232 ±2 mm (9.13 in) |
| Overall Depth | 189 ±3 mm (7.44 in) / 180.7 mm (7.11 in) |
| Mounting Bolt Circle Pitch | Ø 252 ±0.3 mm (9.92 in) |
| Mounting Hole Size | 4 × M10 (Max. Screw Clearance 25 mm / 0.98 in) |
| Blade Count & Geometry | 5 Sickle-Shaped Blades, 0° Pitch Angle |
| Impeller / Blade Material | Sheet Aluminum Insert, Sprayed with Polypropylene (PP) Plastic |
| Electronics Housing Material | Die-Cast Aluminum, Painted Black |
| Rotor Surface | Painted Black |
| Bearing Type | Ball Bearing |
| Installation Position | Shaft Horizontal or Rotor on Bottom (Rotor on Top on Request) |
| Condensation Drainage Holes | On Rotor Side |
| Operating Mode / Duty Cycle | S1 (Continuous Duty) |
| Weight | 26.0 kg (57.32 lbs) |
| Termination Type | Via Integrated Terminal Box with 3 × M20 × 1.5 Cable Glands (Cable Ø 4–10 mm) |
| Power & Relay Terminal Pinout | KL1: L1 (1), L2 (2), L3 (3), PE; KL2 Status Relay (250 VAC / 2 A Max): NO (1), COM (2), NC (3) |
| Control Terminal Pinout (KL3 SELV) | 1: RSA, 2: RSB, 3/10: GND, 4: Ain1 U (0-10V), 5: +10V (10mA), 6: Ain1 I (4-20mA), 7: Din1 (Enable/Reset), 8: Din2 (Param 1/2), 9: Din3 (Normal/Inverse), 11: Ain2 U (0-10V), 12: +20V (50mA), 13: Ain2 I (4-20mA), 14: Aout (0-10V) |
| Control & Communication Features | RS-485 MODBUS-RTU, Integrated PID Controller, 0-10 VDC / PWM & 4-20 mA Inputs, Slave 0-10V Output, Operation/Alarm Display |
| Motor & Drive Protection | Thermal Overload (Motor/Electronics), Locked-Rotor, Reverse Polarity, Line Undervoltage / Phase Failure Detection, Motor Current Limitation, Soft Start, Passive PFC |
| Electrical Protection Class | Class I (Requires Customer Protective Earth Connection) |
| Touch Current (IEC 60990) | <= 3.5 mA (Measuring Circuit Fig. 4, TN System) |
| Insulation Class | Class “F” |
| Ingress Protection (IP) | IP55 |
| Moisture / Environmental Class | F4-1 |
| Operating Temperature | -25°C to +70°C (-13°F to +158°F); Occasional Start-Up Down to -40°C (-40°F) |
| Storage Temperature | -40°C to +80°C (-40°F to +176°F) |
| EMC Immunity & Emission | Immunity per EN 61000-6-2; Emission per EN 55022 (Class A) |
| Standards & Compliance | CE, EAC, UL 1004-7 + 60730, CSA C22.2 No.77 + CAN/CSA-E60730-1, EN 61800-5-1, ErP 2015 |
Applications
ebm-papst A3G800-AU25-05 HyBlade EC axial fan is engineered for high-volume heat rejection in industrial chillers, rooftop air-cooled condensers, dry coolers, and commercial refrigeration evaporators. Its weather-resistant construction and integrated MODBUS/PID speed control make it ideal for data center free-cooling heat exchangers, large HVAC air handling units (AHUs), and wind turbine or power transformer cooling skids. Designed for OEM system integration and facility MRO retrofits, this unit enables demand-controlled airflow modulation with minimal acoustic footprint in continuous-duty outdoor and indoor installations.