4606N ebm-papst 115VAC 119x119x38mm AC Axial Cooling Fan

$59.87

ebm-papst 4606N 115VAC 119x119x38mm AC axial fan, 2650/3100RPM, 87.1/104.8CFM, 20W, featuring all-metal housing & impeller, ball bearings & 90°C max rating.

SKU: 4606N Category: Brand:

Description

ebm-papst 4606N (OEM item number 9274014147 / specification code VUC0119YQHCS) is an industrial 4000N Series tubeaxial cooling fan constructed with an all-metal wall-ring housing and metal impeller in a standard 119.0 × 119.0 × 38.0 mm (4.69 × 4.69 × 1.50 in) frame. Operating on 115 VAC (50/60 Hz) single-phase power, it runs at 2650 RPM (50 Hz) / 3100 RPM (60 Hz) with a 20 W free-air power input to deliver 87.11 CFM (148.0 m³/h) at 50 Hz and 104.77 CFM (178.0 m³/h) at 60 Hz, building up to 0.329 in H₂O (82 Pa) / 0.382 in H₂O (95 Pa) of static pressure.

Engineered for high-temperature reliability, the unit utilizes a spring-preloaded precision ball bearing system, impedance locked-rotor protection, a 2-pin flat plug connection with an 8-32 UNC-2B grounding lug, and wide ambient thermal endurance from -40 °C to +80 °C (50 Hz) / +90 °C (60 Hz).

Key Features

  • Dual-Frequency Aerodynamic Output: Delivers 87.11 CFM (148.0 m³/h) at 50 Hz and 104.77 CFM (178.0 m³/h) at 60 Hz.
  • All-Metal Rugged Construction: Combines a sturdy metal wall-ring frame and metal impeller balanced to G 2.5 for harsh industrial vibration.
  • High-Temperature Thermal Endurance: Operates reliably across -40 °C to +80 °C (50 Hz) and up to +90 °C (194 °F) at 60 Hz.
  • Preloaded Ball Bearing System: Zero-axial-clearance spring-preloaded ball bearings support any shaft mounting orientation and 40,000-hour L10 life at 40 °C.
  • Impedance Protected & Global Approvals: Built-in impedance locked-rotor protection with UL 507, CSA, VDE, CE, CCC, and EAC safety certifications.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) 4606N
OEM Item Number 9274014147 (Spec Code: VUC0119YQHCS)
Product Series 4000N Series
Product Category AC Axial Fans
Fan / Component Type AC Axial Fan (Tubeaxial with Wall Ring)
Motor Design / Technology AC Shaded-Pole External Rotor Motor
Phase & Supply Type 1-Phase AC
Rated Voltage 115 VAC (50 Hz) / 115 VAC (60 Hz)
Operating Voltage Range 103.5 to 126.5 VAC (±10% Tolerance)
Frequency 50 / 60 Hz
Free-Air Speed (RPM) 2650 RPM (50 Hz) / 3100 RPM (60 Hz) (±3% Tolerance)
Free-Air Power Input 20 W (50 Hz) / 20 W (60 Hz) (+5% / -10% Tolerance)
Airflow (Max. Free Air) 87.11 CFM (148.0 m³/h) (50 Hz) / 104.77 CFM (178.0 m³/h) (60 Hz)
Optimal Operating Duty Point 67.10 CFM (114.0 m³/h) at 0.096 in H₂O (24 Pa) (50 Hz) / 74.16 CFM (126.0 m³/h) at 0.129 in H₂O (32 Pa) (60 Hz)
Max. Static Pressure 0.329 in H₂O (82 Pa) (50 Hz) / 0.382 in H₂O (95 Pa) (60 Hz)
Free-Air Sound Pressure Level 45.0 dB(A) (50 Hz) / 49.0 dB(A) (60 Hz) (at 1 m intake, suspended in rubber bands)
Optimal Point Sound Power Level 5.5 bel(A) [55 dB(A)] (50 Hz) / 5.8 bel(A) [58 dB(A)] (60 Hz) (per DIN 45635-38 / ISO 10302)
Airflow Direction Air intake over struts (Exhaust over rotor)
Ingress Protection (IP) IP20
Pollution Degree & Climatic Class Pollution Degree 1 (DIN EN 60664-1); Humid heat constant per DIN EN 60068-2-78 (14 days)
Operating Temperature -40 to +80 °C (-40 to +176 °F) (50 Hz) / -40 to +90 °C (-40 to +194 °F) (60 Hz)
Storage Temperature -40 to +100 °C (-40 to +212 °F)
Service Life L10 (at 40 °C) 37,500 hours (50 Hz) / 40,000 hours (60 Hz)
Service Life L10 (at Max. Temp) 15,000 hours at 80 °C (50 Hz) / 15,000 hours at 90 °C (60 Hz)
Motor & Drive Protection Impedance Locked-Rotor Protection
Electrical Protection Class Class I (with protective earth grounding provision)
Insulation Resistance > 50 MΩ (measured at 500 VDC for 1 min after 48h at 95% RH and 25 °C)
Dielectric Strength 1000 VAC for 1 min (Type Test) / 1500 VAC for 1 sec (Routine Test) per DIN EN 60950 & DIN EN 60335
Clearance / Creepage Distance 2.0 mm (0.079 in) / 1.1 mm (0.043 in)
Termination Type Plug Connection (2 Flat Terminal Pins)
Pin Terminal Blade Width 3.0 ±0.05 mm (0.118 in)
Protective Earth Grounding Thread 8-32 UNC-2B tapped grounding hole (paint-free contact point)
Dimensions (L × H × D) 119.0 × 119.0 × 38.0 mm (4.69 × 4.69 × 1.50 in)
Outer Dimension Tolerances Width/Height: ±0.3 mm (±0.012 in); Axial Depth: +0 / -0.4 mm (+0 / -0.016 in)
Mounting Hole Pitch 104.8 ±0.2 mm (4.126 ±0.008 in) square
Mounting Hole Diameter Ø 4.3 +0.2 mm (0.169 in) / Ø 4.2 ±0.1 mm (0.165 in)
Flange Thickness 4.0 mm (0.157 in)
Recommended Mounting Screw & Torque ISO 4762 M4 degreased (no washer/brace); Wire outlet corner: 190 Ncm, Remaining 3 corners: 310 Ncm
Weight 0.550 kg (1.21 lbs / 550 g)
Bearing Type Dual Ball Bearing (preloaded by spring without axial clearance)
Balance Quality G 2.5 (per DIN ISO 1940)
Housing / Frame Material Metal
Impeller / Blade Material Metal
Direction of Rotation Clockwise (looking at rotor)
Installation Position Any shaft orientation (Horizontal or Vertical)
Standards & Compliance UL 507 (File E38324), CSA C22.2 No. 113, VDE (EN 60950 / VDE 0805), CE, CCC (GB 12350), EAC
RoHS / Environmental Compliance RoHS3 Compliant

Applications

ebm-papst 4606N metal AC axial cooling fan is engineered for continuous thermal management in high-temperature industrial automation enclosures, variable frequency drives (VFDs), and CNC machine tool control cabinets. Its rugged all-metal housing and impeller construction make it highly resilient in welding power supplies, commercial ovens, UPS battery racks, and power conversion switchgear exposed to elevated ambient heat. Standardized 119 mm square mounting dimensions and quick-connect terminal blades also allow straightforward MRO drop-in replacement across legacy European and North American factory machinery.