Description
ebm-papst S4D500-AM03-01 (also known as S4D500AM0301) is a 3-phase HyBlade S-series AC axial fan with a square short nozzle wall ring and an integrated M4D110-GF external rotor motor. Sized around a 500 mm (19.69 in) 5-blade sickle-shaped impeller with “V” airflow direction (intake over struts), it supports two-speed 400 VAC (50 Hz) Delta/Star (Δ/Y) operation as well as high-output 400 VAC and 460 VAC (60 Hz) Delta configurations.
In free-air operation, the unit delivers up to 5410 CFM (9195 m³/h) at 400 VAC 50 Hz (Δ), 4860 CFM (8260 m³/h) at 400 VAC 50 Hz (Y), and 6430 CFM (10920 m³/h) at 460 VAC 60 Hz (Δ), while handling maximum back pressures up to 0.56 in H₂O (140 Pa). Built for harsh industrial and outdoor thermal duty from -40 °C to +65 °C (-40 °F to +149 °F), it features hybrid sheet-steel blades sprayed with polypropylene (PP) plastic, a black RAL 9005 plastic-coated steel guard grille, ball bearings, an IP54 / F4-1 enclosure with rotor-side condensation drainage holes, a PP terminal box, and internal Thermal Overload Protector (TOP) leads.
Key Features
- Two-Speed Delta/Star 3-Phase Operation: Supports 400 VAC 50 Hz Δ/Y speed switching (1390/1180 RPM) plus 400/460 VAC 60 Hz Δ operation.
- High-Volume Aerodynamic Output: Delivers 5410 CFM (9195 m³/h) at 50 Hz and 6430 CFM (10920 m³/h) at 60 Hz free air.
- HyBlade Composite Impeller Design: Five sickle-shaped press-fitted sheet-steel blades sprayed with PP plastic optimize static efficiency and acoustic performance.
- Square Short Nozzle & Guard Grille: Complete bolt-in assembly combines a square full bell-mouth wall plate with a black RAL 9005 guard grille.
- IP54 & F4-1 All-Weather Durability: Operates from -40 °C to +65 °C with Class F insulation, ball bearings, and rotor-side drainage holes.
- Integrated Thermal Overload Protection: Equipped with a PP terminal box and twin gray TOP sensor leads for external motor safety interlocking.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | S4D500-AM03-01 |
| Alternate Part Number | S4D500AM0301 |
| OEM Item Number | 10061-5-9980 |
| Integrated Motor Model | M4D110-GF |
| Product Series | S Series (HyBlade) |
| Product Category | AC Axial Fans |
| Fan / Component Type | AC Axial Fan with Square Short Nozzle & Guard Grille |
| Motor Design / Technology | 3-Phase AC External Rotor Induction Motor (Delta / Star Configurable) |
| Phase & Supply Type | 3-Phase (3~), Delta (Δ) / Star (Y) Connection |
| Rated Voltage | 400 VAC (50 Hz, Δ / Y) / 400 VAC (60 Hz, Δ) / 460 VAC (60 Hz, Δ) |
| Frequency | 50 / 60 Hz |
| Speed (Max. Load) | 1390 RPM (400V 50Hz Δ) / 1180 RPM (400V 50Hz Y) / 1590 RPM (400V 60Hz Δ) / 1640 RPM (460V 60Hz Δ) |
| Free-Air Speed (RPM) | 1420 RPM (400V 50Hz Δ) / 1275 RPM (400V 50Hz Y) / 1680 RPM (460V 60Hz Δ) |
| ErP Optimum Speed (RPM) | 1385 RPM (at 400 VAC, 50 Hz Δ) |
| Power Rating (Max. Load) | 720 W (400V 50Hz Δ) / 550 W (400V 50Hz Y) / 1020 W (400V 60Hz Δ) / 1060 W (460V 60Hz Δ) |
| Free-Air Power Input | 540 W (400V 50Hz Δ) / 433 W (400V 50Hz Y) / 854 W (460V 60Hz Δ) |
| ErP Optimum Efficiency Power | 730 W (0.73 kW at 400 VAC, 50 Hz Δ) |
| Rated Current (Max. Load) | 1.41 A (400V 50Hz Δ) / 0.90 A (400V 50Hz Y) / 1.70 A (400V 60Hz Δ) / 1.64 A (460V 60Hz Δ) |
| Free-Air Current Draw | 1.20 A (400V 50Hz Δ) / 0.71 A (400V 50Hz Y) / 1.41 A (460V 60Hz Δ) |
| Inrush / Starting Current | 6.5 A (400V 50Hz Δ) / 2.2 A (400V 50Hz Y) / 5.9 A (400V 60Hz Δ) / 6.8 A (460V 60Hz Δ) |
| Operating Mode / Duty Cycle | S1 (Continuous Duty) |
| Airflow (Max. Free Air) | 5410 CFM (9195 m³/h at 400V 50Hz Δ) / 4860 CFM (8260 m³/h at 400V 50Hz Y) / 6430 CFM (10920 m³/h at 460V 60Hz Δ) |
| Operating Duty Point Airflow (50 Hz Delta) | 4875 CFM (8280 m³/h) at 0.20 in H₂O (50 Pa); 4230 CFM (7185 m³/h) at 0.40 in H₂O (100 Pa); 3630 CFM (6170 m³/h) at 0.56 in H₂O (140 Pa, Max. Load) |
| Operating Duty Point Airflow (50 Hz Star) | 4290 CFM (7285 m³/h) at 0.16 in H₂O (39 Pa); 3680 CFM (6255 m³/h) at 0.31 in H₂O (76 Pa); 3125 CFM (5310 m³/h) at 0.41 in H₂O (103 Pa, Max. Load) |
| Operating Duty Point Airflow (60 Hz Delta) | 5915 CFM (10045 m³/h) at 0.20 in H₂O (50 Pa); 5390 CFM (9160 m³/h) at 0.40 in H₂O (100 Pa); 4950 CFM (8410 m³/h) at 0.55 in H₂O (138 Pa, Max. Load) |
| ErP Optimum Efficiency Duty Point | 3449.1 CFM (5860 m³/h) at 0.607 in H₂O (151 Pa) |
| Max. Static Pressure | 0.56 in H₂O (140 Pa at 400V 50Hz Δ) / 0.40 in H₂O (100 Pa at 400V 50Hz Y) / 0.52 in H₂O (130 Pa at 400V 60Hz Δ) / 0.55 in H₂O (138 Pa at 460V 60Hz Δ) |
| Sound Pressure Level (Max. Load) | 64 dB(A) (Intake, 400V 50Hz Δ) / 68 dB(A) (Intake, 460V 60Hz Δ) at 1 m |
| Free-Air Sound Pressure Level | 68 dB(A) (Intake, 400V 50Hz Δ) / 71 dB(A) (Intake, 460V 60Hz Δ) at 1 m |
| Sound Power Level (Max. Load) | 72 dB(A) (Intake & Outlet, 400V 50Hz Δ) / 68 dB(A) (Intake & Outlet, 400V 50Hz Y) / 75 dB(A) (Intake & Outlet, 460V 60Hz Δ) |
| Free-Air Sound Power Level | 75 dB(A) (Intake & Outlet, 400V 50Hz Δ) / 72 dB(A) Intake, 73 dB(A) Outlet (400V 50Hz Y) / 79 dB(A) (Intake & Outlet, 460V 60Hz Δ) |
| ErP Efficiency & Grade (EU 327/2011) | Overall Static Efficiency (ηes): 33.4% (2015 Req: 32.8%); Efficiency Grade (N): 40.6 (Req: 40); Category: A (Static); Specific Ratio: 1.00; VSD: No (Test Setup LU-106631) |
| Airflow Direction | “V” (Intake Over Motor Struts, Exhaust Over Rotor) |
| Ingress Protection (IP) | IP54 |
| Moisture / Environmental Class | F4-1 |
| Operating Temperature | -40 °C to +65 °C (-40 °F to +149 °F) at 400V 50Hz (Δ/Y); -40 °C to +50 °C (-40 °F to +122 °F) at 400V 60Hz (Δ); -40 °C to +60 °C (-40 °F to +140 °F) at 460V 60Hz (Δ) |
| Storage Temperature | -40 °C to +80 °C (-40 °F to +176 °F) |
| Motor & Drive Protection | Internal Thermal Overload Protector (TOP) with Basic Insulation (Requires External Evaluation) |
| Electrical Protection Class | Class I (With Customer Connection of Protective Earth) |
| Touch Current (IEC 60990) | <= 3.5 mA (Measuring Circuit Fig. 4, TN System) |
| Insulation Class | Class F |
| Termination Type | Via Terminal Box |
| Cable Exit Orientation | Axial Cable Entry |
| Conduit / Cable Gland Ports | Accepts Cable Diameter 6 mm to 12 mm (0.24 in to 0.47 in); Cable Gland Tightening Torque: 2 ± 0.3 Nm; Terminal Box Cover Torque: 1.5 ± 0.2 Nm |
| Wiring Pinout / Connection | 3-Phase Delta (Δ) / Star (Y): L1 = V1 (Blue), L2 = U1 (Black), L3 = W1 (Brown), W2 (Yellow), U2 (Green), V2 (White), TOP = 2x Gray, PE = Green/Yellow |
| Impeller Size | Ø 500 mm (19.69 in) |
| Weight | 13.0 kg (28.66 lbs) |
| Blade Count & Geometry | 5 Sickle-Shaped Blades (HyBlade Geometry) |
| Bearing Type | Ball Bearing |
| Electronics Housing Material | Polypropylene (PP) Plastic Terminal Box |
| Impeller / Blade Material | Press-Fitted Sheet Steel Blank, Sprayed with Polypropylene (PP) Plastic |
| Guard Grille Material | Steel, Coated with Black Plastic (RAL 9005) |
| Rotor Surface | Painted Black |
| Direction of Rotation | Counterclockwise (CCW), Viewed Toward Rotor |
| Installation Position | Shaft Horizontal or Rotor on Bottom (Rotor on Top Available on Request) |
| Condensation Drainage Holes | On Rotor Side |
| Standards & Compliance | CE, EN 61800-5-1, VDE, EAC, CCC, ISO 5801 (Category A), ISO 13347 |
Applications
ebm-papst S4D500-AM03-01 AC axial fan with square short nozzle is engineered for high-volume heat rejection in commercial HVAC air-cooled condensers, refrigeration evaporators, walk-in cold storage blast freezers, and industrial process chillers. Its bolt-in square wall plate and integrated guard grille allow rapid installation into rooftop dry coolers, heat pump outdoor units, and heavy-duty radiator heat exchangers. The hybrid steel-and-polypropylene HyBlade impeller and weather-sealed housing ensure reliable continuous duty across harsh outdoor and washdown-adjacent OEM and MRO environments.