S4D400-AP12-37 ebm-papst 230/400VAC 400mm AC Axial Fan

$510.00

ebm-papst S4D400-AP12-37 (S4D400AP1237) 230/400VAC Ø400mm 3-phase axial fan, 1450/1690RPM, 2360/2715CFM, 135/185W, with guard grille, M4D074-EI motor & IP44.

SKU: S4D400-AP12-37 Category: Brand:

Description

ebm-papst S4D400-AP12-37 (also known as S4D400AP1237) is an S-series three-phase AC axial fan featuring a 400 mm (15.75 in) 5-blade sickle-shaped impeller, an integrated M4D074-EI external-rotor motor, and an integrated steel guard grille for short-nozzle mounting. Operating on dual-voltage 230 VAC Delta or 400 VAC Star three-phase supplies at 50/60 Hz, it delivers free-air performance of 2,360 CFM (4,010 m³/h) at 1,450 RPM (135 W) on 50 Hz and 2,715 CFM (4,615 m³/h) at 1,690 RPM (185 W) on 60 Hz, reaching up to 204 W (50 Hz) and 292 W (60 Hz) at maximum back pressure of 105 Pa (0.42 in H₂O) and 120 Pa (0.48 in H₂O).

Engineered for demanding refrigeration and HVAC environments, this unit incorporates black-painted sheet steel blades, a phosphated and black plastic-coated steel guard grille, low-temperature lubricated ball bearings rated down to -40 °C (-40 °F), and an ABS terminal box with variable cable routing. It achieves IP44 ingress protection, H1 environmental moisture protection, Class B insulation, and full ErP Directive (EU) 327/2011 compliance (Efficiency Grade N = 41.4).

Key Features

  • Dual-Voltage 3-Phase Operation: Configurable in 230 VAC Delta or 400 VAC Star wiring across 50 Hz and 60 Hz industrial power networks.
  • High-Volume Sickle-Blade Aerodynamics: Delivers 2,360 CFM (4,010 m³/h) at 50 Hz and 2,715 CFM (4,615 m³/h) at 60 Hz with low-noise 5-blade geometry.
  • Extreme Low-Temperature Endurance: Equipped with specialized low-temperature ball bearing lubricant supporting continuous S1 operation from -40 °C to +40 °C (-40 °F to +104 °F).
  • Heavy-Duty Corrosion-Resistant Build: Combines black-painted sheet steel blades, a black-coated rotor, and a phosphated plastic-coated steel guard grille.
  • IP44 & H1 Environmental Protection: Features rotor-side condensation drainage holes, Class B insulation, and H1 moisture resistance for humid heat-exchange duty.
  • ErP Compliant Efficiency: Exceeds EU 327/2011 requirements with a 30.7% overall static efficiency and an Efficiency Grade N of 41.4.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) S4D400-AP12-37
Alternate Part Number S4D400AP1237
OEM Item Number 10518-5-9980
Integrated Motor Model M4D074-EI (Motor Size 74)
Product Series S Series (Sickle-Shaped Blades with Guard Grille for Short Nozzle)
Product Category AC Axial Fans
Fan / Component Type AC Axial Fan with Guard Grille
Motor Design / Technology 3-Phase External Rotor AC Induction Motor (4-Pole)
Phase & Supply Type 3~ (Three-Phase AC, Delta / Star Configurable)
Rated Voltage 230 VAC (Delta Δ) / 400 VAC (Star Y)
Frequency 50 / 60 Hz
Free-Air Speed (RPM) 1450 RPM (50 Hz) / 1690 RPM (60 Hz)
Speed (Max. Curve Load) 1410 RPM at 100 Pa (50 Hz) / 1605 RPM at 120 Pa (60 Hz)
ErP Optimum Speed (RPM) 1390 RPM (at Optimum Efficiency Point)
Free-Air Power Input 135 W (50 Hz) / 185 W (60 Hz)
Power Rating (Max. Curve Load) 204 W at 100 Pa (50 Hz) / 292 W at 120 Pa (60 Hz)
ErP Optimum Efficiency Power 200 W (0.2 kW at Optimum Efficiency Point)
Free-Air Current Draw (230 VAC Delta) 0.76 A (50 Hz) / 0.68 A (60 Hz)
Free-Air Current Draw (400 VAC Star) 0.44 A (50 Hz) / 0.39 A (60 Hz)
Rated Current (Max. Curve Load, 400 VAC Star) 0.50 A at 100 Pa (50 Hz) / 0.54 A at 120 Pa (60 Hz)
Inrush / Starting Current (230 VAC Delta) 3.0 A (50 Hz) / 3.0 A (60 Hz)
Inrush / Starting Current (400 VAC Star) 1.7 A (50 Hz) / 1.7 A (60 Hz)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 2360 CFM (4010 m³/h) at 50 Hz / 2715 CFM (4615 m³/h) at 60 Hz
Operating Duty Point Airflow (50 Hz, 400 VAC Star) 2080 CFM (3530 m³/h) at 0.14 in H₂O (35 Pa, 1435 RPM, 161 W, 0.47 A); 1745 CFM (2965 m³/h) at 0.28 in H₂O (70 Pa, 1420 RPM, 183 W, 0.49 A); 1355 CFM (2300 m³/h) at 0.40 in H₂O (100 Pa, 1410 RPM, 204 W, 0.50 A)
Operating Duty Point Airflow (60 Hz, 400 VAC Star) 2435 CFM (4140 m³/h) at 0.16 in H₂O (40 Pa, 1660 RPM, 223 W, 0.45 A); 2090 CFM (3550 m³/h) at 0.32 in H₂O (80 Pa, 1635 RPM, 257 W, 0.49 A); 1675 CFM (2840 m³/h) at 0.48 in H₂O (120 Pa, 1605 RPM, 292 W, 0.54 A)
ErP Optimum Efficiency Duty Point 1665.7 CFM (2830 m³/h) at 0.325 in H₂O (81 Pa)
Max. Static Pressure 0.42 in H₂O (105 Pa) at 50 Hz / 0.48 in H₂O (120 Pa) at 60 Hz
ErP Efficiency & Grade (EU 327/2011) Overall Static Efficiency ηes: 30.7% (2015 Target: 29.3%), Efficiency Grade N: 41.4 (2015 Target: 40), Measurement Category A, Static Efficiency Category, Specific Ratio: 1.00, No Integrated VSD (Test Setup LU-192397)
Airflow Direction V (Airflow over struts / intake over motor, exhausting through guard grille)
Ingress Protection (IP) IP44 (Installation- and position-dependent per EN 60034-5)
Moisture / Environmental Class H1
Operating Temperature -40 °C to +40 °C (-40 °F to +104 °F)
Storage Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Motor & Drive Protection Motor does not have factory-installed overheating protection (External motor protection required)
Electrical Protection Class Class I (with customer connection of protective earth)
Touch Current (IEC 60990) < 0.75 mA (Measuring circuit Fig. 4, TN system)
Insulation Class Class B
Termination Type Terminal Box
Cable Exit Orientation Variable
Conduit / Cable Gland Ports Max. Cable Diameter 7.5 mm (0.30 in); Cable Gland Tightening Torque: 1.3 ± 0.2 Nm; Terminal Box Cover Tightening Torque: 1.5 ± 0.2 Nm
Wiring Pinout / Connection 3-Phase Star (Y) / Delta (Δ): L1 = U1 (Black), L2 = V1 (Blue), L3 = W1 (Brown), U2 (Green), V2 (White), W2 (Yellow), PE (Green/Yellow)
Impeller Size Ø 400 mm (15.75 in)
Weight 5.7 kg (12.57 lbs)
Blade Count & Geometry 5 Sickle-Shaped Blades
Bearing Type Ball Bearing with Low-Temperature Lubricant
Electronics Housing Material ABS Plastic, Black (Terminal Box)
Impeller / Blade Material Sheet Steel, Painted Black
Guard Grille Material Steel, Phosphated and Coated with Black Plastic
Rotor Surface Painted Black
Direction of Rotation Counterclockwise, Viewed Toward Rotor
Installation Position Shaft Horizontal or Rotor on Bottom (Rotor on Top on Request)
Condensation Drainage Holes On Rotor Side
Standards & Compliance CE, EN 60335-1, EN 60034-5, ISO 5801 Category A, ISO 13347, CCC, EU Regulation 327/2011 (ErP)

Applications

ebm-papst S4D400-AP12-37 three-phase AC axial fan with integrated short-nozzle guard grille is engineered for commercial and industrial heat transfer equipment requiring reliable air movement across wide ambient temperature extremes. Typical OEM and MRO installations include refrigeration condenser coils, cold-storage unit coolers, walk-in blast freezers, air-cooled liquid chillers, and commercial HVAC heat-pump outdoor units. Its sickle-blade impeller profile and low-temperature ball bearing system also suit industrial process heat exchangers, generator radiator cooling plenums, and factory ventilation louvers.