4114NH3 ebm-papst 24VDC 119x119x38mm DC Axial Cooling Fan

$100.80

ebm-papst 4114NH3 24VDC 119x119x38mm axial fan, 6000RPM, 182.46CFM (310m³/h), 350Pa, 19.5W, featuring metal housing, ball bearings & locked-rotor auto-restart.

SKU: 4114NH3 Category: Brand:

Description

ebm-papst 4114NH3 (OEM Item Number 9694300234, internal model code VUC0119YUJBS) is a heavy-duty brushless DC tubeaxial cooling fan from the 4100N series, built with a rugged metal housing, plastic impeller, and precision ball bearing system within a standard 119.0 × 119.0 × 38.0 mm (4.685 × 4.685 × 1.496 in) frame. Operating across a wide 16 to 30 VDC supply range (24 VDC nominal), its electronically speed-controlled motor maintains a regulated 6000 RPM at 19.5 W (800 mA) to deliver 182.46 CFM (310.0 m³/h) of free-air flow and up to 1.405 in H₂O (350 Pa) of static pressure.

Engineered for high-reliability industrial duty with an L10IPC life of 110,000 hours at 40 °C, it incorporates rectifying diode reverse-polarity protection, locked-rotor auto-restart, and 310 mm (12.205 in) AWG 22 lead wires.

Key Features

  • High-Pressure Tubeaxial Aerodynamics: Delivers 182.46 CFM (310.0 m³/h) maximum free-air volume and 1.405 in H₂O (350 Pa) static pressure at 6000 RPM.
  • Integrated Speed Regulation: Internal electronics maintain constant 6000 RPM speed from 24 VDC up to 30 VDC while supporting 16 VDC operation.
  • Comprehensive Motor Protection: Features rectifying diode reverse-polarity protection and automatic locked-rotor restart with a 1.0 s / 5.5 s clock cycle.
  • Rugged Metal-Frame Construction: Combines a durable metal outer housing, aerodynamic plastic impeller, and spring-compensated zero-play ball bearings for any-orientation mounting.
  • Extended Industrial Service Life: Rated for 65,000 hours L10 (110,000 hours per IPC 9591) at 40 °C across a -20 °C to +65 °C range.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) 4114NH3
OEM Item Number 9694300234
Internal Specification Code VUC0119YUJBS
Product Series 4100N
Product Category DC Axial Fans
Fan / Component Type DC Tubeaxial Cooling Fan
Motor Design / Technology Electronically Commutated Brushless DC Motor with Integrated Speed Control
Phase & Supply Type DC Supply
Rated Voltage 24 VDC
Operating Voltage Range 16 ~ 30 VDC
Max. Permissible Voltage (Approval) 30.0 VDC (at 65.0 °C / 149.0 °F)
Speed (at 24 VDC Nominal, Free Air) 6000 RPM (±10%)
Speed (at 16 VDC Min. Voltage, Free Air) 4700 RPM (±10%)
Speed (at 30 VDC Max. Voltage, Free Air) 6000 RPM (±10%)
Power Rating (at 24 VDC Nominal, Free Air) 19.5 W (±15%)
Power Input (at 16 VDC Min. Voltage, Free Air) 10.4 W (±15%)
Power Input (at 30 VDC Max. Voltage, Free Air) 20.4 W (±15%)
Rated Current (at 24 VDC Nominal, Free Air) 800 mA / 0.80 A (±15%)
Current Draw (at 16 VDC Min. Voltage, Free Air) 650 mA / 0.65 A (±15%)
Current Draw (at 30 VDC Max. Voltage, Free Air) 680 mA / 0.68 A (±15%)
Inrush / Starting Current 3300 mA (3.30 A)
Locked Rotor Current (at 24 VDC) Approx. 3300 mA (3.30 A)
Max. Residual Current (at 24 VDC) <= 10 mA (Reverse Polarity)
Airflow (Max. Free Air) 182.46 CFM (310.0 m³/h / 5.17 m³/min)
Optimal Operating Duty Point 141.26 CFM (240.0 m³/h) at 0.430 in H₂O (107 Pa)
Max. Static Pressure 1.405 in H₂O (350 Pa)
Sound Pressure Level (Free Air, Intake) 64.0 dB(A) (at 1 m distance)
Sound Power Level (Optimal Operating Point) 7.1 bel(A) / 71.0 dB(A) (per DIN 45635-38 / ISO 10302)
Airflow Direction Air Intake Over Struts
Ingress Protection (IP) IP20
Pollution Degree Pollution Degree 1 (per DIN EN 60664-1, Dry Non-Conductive)
Operating Temperature -20 ~ 65 °C (-4 ~ 149 °F)
Storage Temperature -40 ~ 80 °C (-40 ~ 176 °F)
Climatic & Humidity Rating Constant Humid Heat (14 Days per DIN EN 60068-2-78)
Service Life L10 (at 40 °C) 65,000 Hours
Service Life L10 (at Max. Temp 65 °C) 37,500 Hours
Service Life L10IPC (at 40 °C) 110,000 Hours (per IPC 9591)
Motor & Drive Protection Rectifying Diode Reversed Polarity Protection, Locked-Rotor Auto-Restart
Locked-Rotor Restart Timing (t3 / t4) 1.0 s On / 5.5 s Off (Typical Clock Signal)
Electrical Protection Class Protection Class III
Insulation Resistance > 10 MΩ (at 500 VDC for 1 Min after 48h at 95% RH, 25 °C)
Dielectric Strength (Type Test) 500 VAC for 1 Minute (per DIN EN 60950 / DIN EN 60335)
Dielectric Strength (Routine Test) 850 VDC for 1 Second
Clearance / Creepage Distance 1.0 mm (0.039 in) / 1.2 mm (0.047 in)
Control / Signal Features Internal Electronic Speed Control
Termination Type 2 Single Lead Wires
Lead Wire Gauge & Spec AWG 22, 1.7 mm (0.067 in) Insulation Diameter
Cable / Lead Length 310.0 ± 10.0 mm (12.205 ± 0.394 in)
Wiring Pinout / Connection Wire 1 (Red): +UB (Positive Supply); Wire 2 (Blue): -GND (Ground)
Dimensions (L × H × D) 119.0 × 119.0 × 38.0 mm (4.685 × 4.685 × 1.496 in)
Total Axial Depth 38.0 mm (1.496 in)
Mounting Screw Size ISO 4762 – M4 (Degreased, Without Additional Brace or Washer)
Max. Mounting Torque (Wire Outlet Corner) 420 Ncm (4.20 Nm / 37.17 in-lbs) Across Both Flanges
Max. Mounting Torque (Remaining Corners) 560 Ncm (5.60 Nm / 49.56 in-lbs) Across Both Flanges
Weight 0.390 kg (0.860 lbs / 390 g)
Bearing Type Ball Bearing (Zero Axial Play via Spring Compensation)
Housing / Frame Material Metal
Impeller / Blade Material Plastic
Direction of Rotation Clockwise (Looking at Rotor)
Installation Position Any Shaft Orientation (Horizontal or Vertical)
Standards & Compliance CE, UL 507 (File E38324), CSA C22.2 No. 113, VDE (EN 60950 / VDE 0805), EAC, DIN EN ISO 5801
RoHS / Environmental Compliance RoHS3 Compliant

Applications

The ebm-papst 4114NH3 DC tubeaxial fan is engineered for high-impedance forced-air cooling in industrial automation cabinets, variable frequency drives (VFDs), and servo amplifier enclosures. Its elevated static pressure capability and rugged metal housing make it ideal for densely packed telecom rectifiers, uninterruptible power supply (UPS) battery banks, welding inverters, and CNC machine tool control panels. Equipment OEMs and MRO technicians deploy this unit in sheltered industrial and IT power systems requiring dependable heat dissipation across fluctuating DC bus supplies.