R2E190-AO26-30 ebm-papst 230VAC 190mm AC Centrifugal Fan

$744.00

ebm-papst R2E190-AO26-30 (R2E190AO2630) 230VAC Ø190mm backward-curved centrifugal fan, 2500/2700RPM, 335/365CFM, 58/75W, with PA impeller, Molex plug & IP44.

SKU: R2E190-AO26-30 Category: Brand:

Description

ebm-papst R2E190-AO26-30 (also known as R2E190AO2630) is a single-intake, unhoused backward-curved AC centrifugal motorized impeller driven by an integrated M2E068-BF external-rotor capacitor motor in a compact Ø190 × 68.5 mm (7.48 × 2.70 in) footprint. Operating on single-phase 230 VAC (50/60 Hz) power with a 2 µF / 400 VDB run capacitor, this unit delivers 2500 RPM (50 Hz) / 2700 RPM (60 Hz) free-air speed, drawing 58 W (0.26 A) at 50 Hz and 75 W (0.34 A CE) or 80 W (0.35 A UL 2111) at 60 Hz. It generates a maximum free-air flow of 335 CFM (570 m³/h) at 50 Hz and 365 CFM (620 m³/h) at 60 Hz, sustaining operating back pressures up to 0.96 in H₂O (240 Pa) at 50 Hz and 1.20 in H₂O (300 Pa) at 60 Hz.

Built for continuous S1 industrial duty from -25 °C to +50 °C (50 Hz) or +55 °C (60 Hz), it features a 7-blade polyamide (PA) plastic impeller, maintenance-free ball bearings, IP44 / H1 environmental protection, an internally connected thermal overload protector (TOP), and a 500 mm (19.69 in) AWG20 PVC lead cable terminated with a 3-pin Molex 03-06-2032 connector housing.

Key Features

  • Backward-Curved Aerodynamics: Unhoused 7-blade Ø190 mm polyamide impeller delivers 335/365 CFM free air and overcomes static pressures up to 240/300 Pa.
  • Dual-Frequency 230 VAC Motor: Integrated M2E068-BF external-rotor AC motor operates at 2500 RPM (50 Hz) and 2700 RPM (60 Hz) with a 2 µF capacitor.
  • Pre-Terminated Molex Harness: Equipped with a 500 mm AWG20 PVC cable featuring a 3-pin Molex 03-06-2032 housing and 02-06-2201 plug pins.
  • Thermal & Ingress Protection: Internal thermal overload protector (TOP), IP44 ingress rating, H1 moisture class, and Class B insulation safeguard continuous S1 operation.
  • Multi-Orientation Ball Bearings: Precision ball bearing system supports any mounting orientation across a wide -25 °C to +55 °C operating temperature range.
  • Global Safety Certifications: Fully compliant with CE, UL 1004-3 (UL 2111), CSA C22.2 No. 77, CCC, EN 60034-1, and EN 60204-1 standards.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) R2E190-AO26-30
Alternate Part Number R2E190AO2630
OEM Item Number 11066-5-9980
Integrated Motor Model M2E068-BF (Motor Size 68)
Product Series R2E190
Product Category AC Centrifugal Fans
Fan / Component Type Backward-Curved Motorized Impeller (Single-Intake, Unhoused)
Motor Design / Technology Single-Phase AC External-Rotor Permanent Split Capacitor (PSC) Motor
Phase & Supply Type 1~ (Single-Phase AC)
Rated Voltage 230 VAC
Frequency 50 / 60 Hz
Free-Air Speed (RPM) 2500 RPM (50 Hz) / 2700 RPM (60 Hz)
Speed at Peak Curve Power (RPM) 2415 RPM (50 Hz at 160 Pa) / 2570 RPM (60 Hz at 200 Pa)
Speed at Max. Curve Pressure (RPM) 2515 RPM (50 Hz at 240 Pa) / 2780 RPM (60 Hz at 300 Pa)
Free-Air Power Input 58 W (50 Hz CE) / 75 W (60 Hz CE)
UL 2111 Rated Power Input 80 W (60 Hz Free Air)
Peak Curve Power Input 61 W (50 Hz at 160 Pa) / 79 W (60 Hz at 200 Pa)
Free-Air Current Draw 0.26 A (50 Hz CE) / 0.34 A (60 Hz CE)
UL 2111 Rated Current Draw 0.35 A (60 Hz Free Air)
Peak Curve Current Draw 0.27 A (50 Hz at 160 Pa) / 0.35 A (60 Hz at 200 Pa)
Inrush / Starting Current 0.40 A (50 Hz) / 0.41 A (60 Hz)
Run Capacitor 2 µF, 400 VDB
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 335 CFM (570 m³/h) at 50 Hz / 365 CFM (620 m³/h) at 60 Hz (0 Pa)
Operating Duty Point 2 Airflow 275 CFM (465 m³/h) at 0.32 in H₂O (80 Pa, 50 Hz) / 290 CFM (490 m³/h) at 0.40 in H₂O (100 Pa, 60 Hz)
Operating Duty Point 3 Airflow 190 CFM (325 m³/h) at 0.64 in H₂O (160 Pa, 50 Hz) / 185 CFM (310 m³/h) at 0.80 in H₂O (200 Pa, 60 Hz)
Operating Duty Point 4 Airflow 85 CFM (145 m³/h) at 0.96 in H₂O (240 Pa, 50 Hz) / 80 CFM (135 m³/h) at 1.20 in H₂O (300 Pa, 60 Hz)
Max. Measured Curve Static Pressure 0.96 in H₂O (240 Pa) at 50 Hz / 1.20 in H₂O (300 Pa) at 60 Hz
Min. Back Pressure 0 in H₂O (0 Pa)
Air Performance Measurement Standard ISO 5801 Installation Category A (Air Density ρ = 1.15 kg/m³ ± 2%, Test Setups LU-53162-1 & LU-53163-1)
Airflow Direction Axial Intake, Radial Centrifugal Discharge
Ingress Protection (IP) IP44 (Installation- and Position-Dependent)
Moisture / Environmental Class H1
Operating Temperature (50 Hz) -25 °C to +50 °C (-13 °F to +122 °F)
Operating Temperature (60 Hz) -25 °C to +55 °C (-13 °F to +131 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Motor & Drive Protection Thermal Overload Protector (TOP) Internally Connected
Electrical Protection Class Class I (With Customer Protective Earth Connection to Marked PE Point)
Touch Current (IEC 60990) < 0.75 mA (Measuring Circuit Fig. 4, TN System)
Insulation Class Class B
Termination Type 3-Pin Connector Housing Molex 03-06-2032 with 3x Molex 02-06-2201 Plug Pins
Cable Exit Orientation Variable
Lead Wire Gauge & Spec AWG20 PVC Insulated Cable
Cable / Lead Length 500 ±20 mm (19.69 ±0.79 in)
Wire Stripped / Unjacketed Length 40 ±10 mm (1.57 ±0.39 in)
Wiring Pinout / Connection Pin 1.1 (Z): Brown | Pin 1.2 (U2): Black | Pin 1.3 (U1): Blue | PE: Green/Yellow
Impeller Size Ø190 mm (7.48 in)
Outer Dimensions (Ø × D) Ø190 × 68.5 ±1 mm (7.48 × 2.70 ±0.04 in)
Total Axial Depth 68.5 ±1 mm (2.70 ±0.04 in)
Impeller Axial Width 62.8 mm (2.47 in)
Inlet Step Depth 44.6 mm (1.76 in)
Inlet Nozzle / Intake Ring Diameter Ø125.5 mm (4.94 in) (With Optional Inlet Ring)
Mounting Hole Pitch Ø58 mm (2.28 in) Rotor Bolt Circle (4 × 90°)
Mounting Hole Diameter / Thread Size 4 × M4 Threaded Holes
Max. Screw Clearance 5 mm (0.20 in)
Weight 1.2 kg (2.65 lbs)
Blade Count & Geometry 7 Backward-Curved Blades
Bearing Type Ball Bearing
Impeller / Blade Material Polyamide (PA) Plastic
Rotor Surface Painted Black
Direction of Rotation Clockwise (Viewed Toward Rotor)
Installation Position Any
Condensation Drainage Holes None
Compatible Inlet Ring (Optional) Part No. 09576-2-4013 (Ø170 mm Outer, Ø158 mm Bolt Circle with 4× Ø4.5 mm Holes, Not Included)
Standards & Compliance CE, UL 1004-3, UL 2111, CSA C22.2 No. 77, CCC, EN 60034-1, EN 60204-1

Applications

ebm-papst R2E190-AO26-30 backward-curved centrifugal motorized impellers are engineered for pressurized plenum and ductless air movement across commercial HVAC, cleanroom, and industrial electronics cooling systems. Typical OEM and MRO installations include data center CRAC/CRAH precision air handlers, ceiling Fan Filter Units (FFUs), heat recovery ventilation (HRV) cassettes, and refrigerated display cases. Its compact unhoused profile and plug-and-play Molex harness also make it a direct drop-in replacement for power converter cabinets, telecom rectifiers, and medical or laboratory extraction hoods.