Description
ebm-papst 7210N-181 (also known as 7210N181) is a high-voltage 110 VDC brushless axial cooling fan from the 7200 N series, engineered with a 150.0 mm (5.906 in) nominal impeller diameter inside a 172.0 mm (6.772 in) round metal housing with a 55.0 mm (2.165 in) axial depth. Operating across a wide 75.0 to 135.0 VDC supply range, it incorporates internal electronic speed regulation to maintain a constant 3,050 RPM free-air speed at nominal 110.0 VDC while consuming 16 W (145 mA).
Measured in accordance with DIN EN ISO 5801, this unit delivers 203.06 CFM (345.0 m³/h) of maximum free-air airflow and builds up to 0.643 in H₂O (160 Pa) of static pressure, with an optimal acoustic operating point of 129.49 CFM (220.0 m³/h) at 0.201 in H₂O (50 Pa). Built for continuous industrial reliability from -25 °C to +75 °C (-13 °F to +167 °F), it features precision ball bearings rated for a 70,000-hour L10 life at 40 °C, rectifying diode reverse-polarity protection, locked-rotor auto-restart, and 365 mm (14.37 in) 22 AWG lead wires.
Key Features
- Wide 110 VDC Regulated Input: Operates from 75.0 to 135.0 VDC with speed-controlled electronics holding 3,050 RPM across nominal and high-line voltages.
- High-Pressure Axial Aerodynamics: Generates 203.06 CFM (345.0 m³/h) free-air flow and 0.643 in H₂O (160 Pa) maximum static pressure over struts.
- Rugged Metal & Plastic Construction: Combines a sturdy Ø172 mm metal housing with a precision-molded plastic impeller and any-orientation ball bearing system.
- Comprehensive Motor Protection: Integrates rectifying diode reverse-polarity protection and automatic locked-rotor restart with a 0.5 s / 5.0 s clock cycle.
- Extended Thermal Endurance: Rated for -25 °C to +75 °C ambient operation with 70,000-hour L10 life at 40 °C (117,500 hours per IPC 9591).
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | 7210N-181 |
| Alternate Part Number | 7210N181 |
| Product Series | 7200 N Series |
| Product Category | DC Axial Fans |
| Fan / Component Type | Round-Frame Tubeaxial DC Cooling Fan |
| Motor Design / Technology | Electronically Commutated Brushless DC Motor (Speed-Controlled) |
| Phase & Supply Type | DC (Direct Current) |
| Rated Voltage | 110.0 VDC |
| Operating Voltage Range | 75.0 to 135.0 VDC |
| Free-Air Speed (RPM) | 3,050 RPM ±7.5% (at 110.0 VDC Nominal) |
| Speed at Min. Voltage (75 VDC) | 2,900 RPM ±17.5% (at Free Air) |
| Speed at Max. Voltage (135 VDC) | 3,050 RPM ±7.5% (at Free Air) |
| Free-Air Power Input | 16.0 W ±17.5% (at 110.0 VDC Nominal) |
| Power Input at 120 VDC | 14.4 W (at Free Air) |
| Power Input at Min. Voltage (75 VDC) | 10.5 W ±22.5% (at Free Air) |
| Free-Air Current Draw | 145 mA ±17.5% (at 110.0 VDC Nominal) |
| Current Draw at 120 VDC | 120 mA (at Free Air) |
| Current Draw at Min. Voltage (75 VDC) | 140 mA ±22.5% (at Free Air) |
| Locked-Rotor Current (Iblock) | Approx. 570 mA (at 110.0 VDC Nominal) |
| Operating Mode / Duty Cycle | S1 (Continuous Duty) |
| Airflow (Max. Free Air) | 203.06 CFM (345.0 m³/h) at 0 Pa (3,050 RPM) |
| Optimal Operating Duty Point | 129.49 CFM (220.0 m³/h) at 0.201 in H₂O (50.0 Pa) |
| Max. Static Pressure | 0.643 in H₂O (160.0 Pa) at 0 CFM |
| Aerodynamic Test Standard | DIN EN ISO 5801 (Double-Chamber Intake Rig at 1.2 kg/m³, 23 °C) |
| Free-Air Sound Pressure Level | 53.0 dB(A) (Measured at 1 m Distance from Air Intake) |
| Optimal Point Sound Power Level | 6.2 bel(A) / 62.0 dB(A) (at 220.0 m³/h @ 50 Pa per DIN 45635-38 / ISO 10302) |
| Airflow Direction | Air Outlet Over Struts (Blowing Over Struts) |
| Direction of Rotation | Counterclockwise (Looking at Rotor) |
| Operating Temperature | -25 °C to +75 °C (-13 °F to +167 °F) |
| Storage Temperature | -40 °C to +80 °C (-40 °F to +176 °F) |
| Climatic & Humidity Rating | Constant Humid Heat (14 Days per DIN EN 60068-2-78); Pollution Degree 1 (DIN EN 60664-1) |
| Service Life L10 (at 40 °C) | 70,000 Hours |
| Service Life L10 (at Max. Temp 75 °C) | 14,000 Hours |
| Service Life L10IPC (at 40 °C) | 117,500 Hours (per IPC 9591) |
| Motor & Drive Protection | Rectifying Diode Reverse-Polarity Protection; Automatic Locked-Rotor Restart |
| Locked-Rotor Clock Signal (t3 / t4) | 0.5 s On / 5.0 s Off (Typical) |
| Electrical Protection Class | Class I |
| Insulation Resistance | > 10 MΩ (at 500 VDC for 1 Min after 48h at 95% RH, 25 °C) |
| Dielectric Strength (Type Test) | 1,000 VAC for 1 Minute (per DIN EN 60950 / VDE 0805 & DIN EN 60335 / VDE 0700) |
| Dielectric Strength (Routine Test) | 1,000 VAC for 1 Second |
| Clearance / Creepage Distance | 1.0 mm / 1.5 mm (0.039 in / 0.059 in) |
| Termination Type | 2 Single Lead Wires |
| Lead Wire Gauge & Spec | 22 AWG (Insulation Outer Diameter: 1.70 mm / 0.067 in) |
| Cable / Lead Length | 365.0 ±10.0 mm (14.370 ±0.394 in) |
| Wire Stripped / Tube Length | 10.0 ±5.0 mm (0.394 ±0.197 in) |
| Wiring Pinout / Connection | Wire 1 (Red): +UB (Positive DC Supply) | Wire 2 (Black): -GND (Ground) |
| Nominal Impeller / Duct Size | Ø 150.0 mm (5.906 in) |
| Outer Dimensions (Ø × D) | Ø 172.0 ±0.5 mm × 55.0 ±0.4 mm (6.772 in × 2.165 in) |
| Total Axial Depth | 55.0 ±0.4 mm (2.165 ±0.016 in) |
| Enclosure Cutout Size | Ø 149.2 mm (5.874 in) Mounting Wall Bore |
| Mounting Hole Pitch | 162.0 ±0.3 mm (6.378 ±0.012 in) Bolt Circle |
| Mounting Hole Diameter | Ø 4.3 +0.15 mm (0.169 in) |
| Flange Thickness | 6.0 ±0.3 mm (0.236 ±0.012 in) |
| Recommended Mounting Screw & Torque | ISO 4762 M4 Degreased Screw (Max. Torque: 560 Ncm / 49.56 in-lbs Across Both Flanges) |
| Weight | 0.725 kg (1.598 lbs) |
| Bearing Type | Ball Bearing |
| Housing / Frame Material | Metal |
| Impeller / Blade Material | Plastic |
| Installation Position | Any Shaft Orientation (Horizontal or Vertical) |
| Standards & Compliance | EAC Certified; Tested to DIN EN 60950, DIN EN 60335, DIN EN 60664-1, DIN EN ISO 5801 |
Applications
ebm-papst 7210N-181 round-frame DC axial cooling fans are engineered for industrial and utility systems operating on 110 VDC station battery buses or high-voltage DC backplanes. Typical installations include railway traction converters, Rolling stock auxiliary power cabinets, substation switchgear protection relays, utility UPS battery racks, and heavy-duty telecommunications rectifiers. Its rugged metal frame and wide ambient temperature tolerance make it an ideal OEM component and direct MRO drop-in replacement for enclosed power electronics, industrial automation drives, and sheltered control room cabinetry.