Description
ebm-papst W2D300-CP02-16 (also known as W2D300CP0216, OEM Item No. 12898-5-9980) is an industrial three-phase S-series AC axial fan unit featuring a 300 mm (11.81 in) 5-blade sickle-shaped impeller, a pre-galvanized sheet steel wall ring housing, and an integrated steel guard grille powered by the M2D074-DF external rotor motor. Operating on 50 Hz three-phase supplies wired in either Delta (220–230 VAC) or Star (380–400 VAC), it delivers a free-air flow of 1845 CFM (3135 m³/h) at 2580 RPM with a nominal free-air power input of 210 W (0.62 A at 230 VAC Δ / 0.36 A at 400 VAC Y) and reaches up to 281 W (0.44 A at 400 VAC Y) at its 160 Pa (0.64 in H₂O) high-load curve duty point.
Engineered for continuous S1 operation across ambient temperatures from -25 °C to +75 °C (-13 °F to +167 °F), the assembly incorporates ball bearings, RAL 9005 black plastic-coated steel components, an ABS terminal box for variable cable entry, and IP44 ingress protection.
Key Features
- Dual-Voltage Three-Phase Motor: Configurable M2D074-DF motor supports 220/230 VAC Delta and 380/400 VAC Star 50 Hz connections with reversible phase rotation.
- High-Airflow Sickle Impeller: Aerodynamic 300 mm 5-blade painted sheet steel impeller delivers up to 1845 CFM (3135 m³/h) free-air output.
- Full Nozzle Housing & Guard: Pre-galvanized sheet steel wall ring and steel guard grille finished in durable RAL 9005 black plastic coating.
- Wide Thermal & IP44 Rating: Ball bearing system and Class F insulation support S1 continuous duty from -25 °C to +75 °C under IP44 protection.
- Integrated ABS Terminal Box: Features variable cable exit orientation accepting up to 10 mm cord diameter with rotor-side condensation drainage holes.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | W2D300-CP02-16 |
| Alternate Part Number | W2D300CP0216 |
| OEM Item Number | 12898-5-9980 |
| Integrated Motor Model | M2D074-DF |
| Product Series | S Series (W2D300) |
| Product Category | AC Axial Fans |
| Fan / Component Type | AC Axial Fan with Wall Ring Housing and Guard Grille |
| Motor Design / Technology | Three-Phase AC External Rotor Induction Motor |
| Phase & Supply Type | 3~ (Three-Phase AC, Delta Δ / Star Y Configurable) |
| Rated Voltage | 220 / 230 VAC (Delta Δ) | 380 / 400 VAC (Star Y) |
| Frequency | 50 Hz |
| Free-Air Speed (RPM) | 2560 RPM (at 220 VAC Δ / 380 VAC Y) | 2580 RPM (at 230 VAC Δ / 400 VAC Y) |
| Speed (Max. Curve Load) | 2385 RPM (at 400 VAC Y, 160 Pa / 0.64 in H₂O) |
| ErP Optimum Speed (RPM) | 2455 RPM (at 125 Pa / 0.502 in H₂O) |
| Free-Air Power Input | 195 W (at 220 VAC Δ / 380 VAC Y) | 210 W (at 230 VAC Δ / 400 VAC Y) |
| Power Rating (Max. Curve Load) | 281 W (at 400 VAC Y, 160 Pa / 0.64 in H₂O) |
| ErP Optimum Efficiency Power | 250 W (0.25 kW at 125 Pa / 0.502 in H₂O) |
| Free-Air Current Draw | 0.59 A (220 VAC Δ) / 0.62 A (230 VAC Δ) | 0.34 A (380 VAC Y) / 0.36 A (400 VAC Y) |
| Rated Current (Max. Curve Load) | 0.44 A (at 400 VAC Y, 160 Pa / 0.64 in H₂O) |
| Inrush / Starting Current | 2.0 A (at 230 VAC Δ) | 1.16 A (at 400 VAC Y) |
| Operating Mode / Duty Cycle | S1 (Continuous Duty) |
| Airflow (Max. Free Air) | 1845 CFM (3135 m³/h at 0 Pa, 400 VAC Y, 50 Hz) |
| Operating Duty Point Airflow (Point 2) | 1650 CFM (2805 m³/h) at 0.20 in H₂O (50 Pa) — 2540 RPM, 228 W, 0.36 A |
| Operating Duty Point Airflow (Point 3) | 1440 CFM (2445 m³/h) at 0.40 in H₂O (100 Pa) — 2490 RPM, 244 W, 0.39 A |
| Operating Duty Point Airflow (Point 4 Max. Curve) | 995 CFM (1690 m³/h) at 0.64 in H₂O (160 Pa) — 2385 RPM, 281 W, 0.44 A |
| ErP Optimum Efficiency Duty Point | 1300.76 CFM (2210 m³/h) at 0.502 in H₂O (125 Pa) — 2455 RPM, 250 W |
| Max. Static Pressure | 0.76 in H₂O (190 Pa at 220/380 VAC) | 0.80 in H₂O (200 Pa at 230/400 VAC) |
| ErP Efficiency & Grade (EU 327/2011) | Overall Static Efficiency ηes: 29.9% (Req. 2015: 29.9%), Efficiency Grade N: 40 (Req. 2015: 40), Measurement Category: A, Efficiency Category: Static, VSD: No, Specific Ratio: 1.00 (Test Setup LU-62732) |
| Airflow Direction | Direction “A” (Intake over Guard Grille, Exhaust over Rotor / Struts) |
| Ingress Protection (IP) | IP44 (Installation- and Position-Dependent per EN 60034-5) |
| Moisture / Environmental Class | H0+ |
| Operating Temperature | -25 °C to +75 °C (-13 °F to +167 °F) |
| Storage Temperature | -40 °C to +80 °C (-40 °F to +176 °F) |
| Electrical Protection Class | Class I (With Customer Connection of Protective Earth) |
| Touch Current (IEC 60990) | < 0.75 mA (Measuring Circuit Fig. 4, TN System) |
| Insulation Class | Class “F” |
| Termination Type | Via Integrated Terminal Box (Cover Tightening Torque: 0.5 ± 0.1 Nm) |
| Cable Exit Orientation | Variable |
| Conduit / Cable Gland Ports | Accepts Cable Diameter up to Max. 10 mm (0.39 in), Gland Tightening Torque: 1.3 ± 0.2 Nm |
| Wiring Pinout / Connection | 3-Phase Delta (Δ) / Star (Y) — L1 (U1): Black, L2 (V1): Blue, L3 (W1): Brown, U2: Green, V2: White, W2: Yellow, PE: Green/Yellow (Reversible Rotation by Swapping Two Phases) |
| Impeller Size | Ø 300 mm (11.81 in) |
| Weight | 5.33 kg (11.75 lbs) |
| Blade Count & Geometry | 5 Sickle-Shaped Blades (S Series) |
| Bearing Type | Ball Bearing |
| Electronics Housing Material | ABS Plastic (Terminal Box) |
| Housing / Scroll / Frame Material | Pre-Galvanized Sheet Steel, Coated with Black Plastic (RAL 9005) |
| Impeller / Blade Material | Sheet Steel, Painted Black |
| Guard Grille Material | Steel, Coated with Black Plastic (RAL 9005) |
| Rotor Surface | Painted Black |
| Direction of Rotation | Clockwise, Viewed Toward Rotor |
| Installation Position | Shaft Horizontal or Rotor on Bottom (Rotor on Top Available on Request) |
| Condensation Drainage Holes | On Rotor Side |
| Standards & Compliance | EN 60335-1, ISO 5801 (Category A), ISO 13347, CE |
Applications
ebm-papst W2D300-CP02-16 three-phase wall-ring axial fan is engineered for high-throughput thermal management across commercial refrigeration condensers, walk-in cold storage evaporators, and industrial heat exchangers. Its full-nozzle steel housing and integrated guard grille allow direct panel or bulkhead mounting in air-cooled liquid chillers, dry coolers, and large HVAC air handling units. In factory automation and power conversion environments, it provides reliable forced-air ventilation for high-power variable frequency drive (VFD) cabinets, transformer enclosures, and industrial drying or curing machinery.