S4E450-8317078900 ebm-papst 230VAC 450mm AC Axial Fan

$198.00

ebm-papst S4E450-8317078900 (S4E4508317078900) 230VAC 450mm AC axial fan, 1400/1600RPM, 3220/3657CFM, 245/355W, with guard grille, ABS terminal box & IP44.

SKU: S4E450-8317078900 Category: Brand:

Description

ebm-papst S4E450-8317078900 (also known as S4E4508317078900, OEM item number 8317078900) is an S-series AC axial fan equipped with a 5-blade sickle-shaped sheet steel impeller, a short-nozzle steel guard grille (Ø 522 mm / 20.55 in outer mounting ring, 179.8 mm / 7.08 in total axial depth), and an integrated M4E074-GA single-phase external rotor motor. Operating on 230 VAC (50/60 Hz), it delivers a free-air speed of 1400 RPM (50 Hz) / 1600 RPM (60 Hz) at 245 W (1.10 A) / 355 W (1.53 A) input, generating up to 3,219.8 CFM (5,471 m³/h) at 50 Hz and 3,656.5 CFM (6,213 m³/h) at 60 Hz, while reaching 296 W (1.33 A) at 85 Pa (50 Hz) and 369 W (1.61 A) at 35 Pa (60 Hz) under maximum back pressure.

Engineered for continuous S1 operation down to -40 °C (-40 °F), this unit incorporates ball bearings with low-temperature lubricant, an internally connected thermal overload protector (TOP), rotor-side condensation drainage holes, and an IP44 black ABS terminal box housing a pre-wired 8 µF / 400 VDB (Class S0) run capacitor.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) S4E450-8317078900
Alternate Part Number S4E4508317078900
OEM Item Number 8317078900
Integrated Motor Model M4E074-GA (Size 74)
Product Series S4E450 (S Series Sickle-Blade)
Product Category AC Axial Fans
Fan / Component Type AC Axial Fan with Guard Grille for Short Nozzle
Motor Design / Technology 4-Pole Single-Phase AC External Rotor Capacitor Motor
Phase & Supply Type 1~ (Single-Phase AC)
Rated Voltage 230 VAC
Frequency 50 / 60 Hz
Free-Air Speed (RPM) 1400 RPM (50 Hz) / 1600 RPM (60 Hz) (Nominal at 0 Pa Free Air)
Speed (Max. Load) 1340 RPM (50 Hz at 85 Pa) / 1546 RPM (60 Hz at 35 Pa)
Intermediate Curve Speed (50 Hz) 1377 RPM (at 30 Pa, Point 2); 1358 RPM (at 60 Pa, Point 3)
Intermediate Curve Speed (60 Hz) 1568 RPM (at 20 Pa, Point 2)
Free-Air Power Input 245 W (50 Hz) / 355 W (60 Hz) (Nominal at 0 Pa Free Air)
Power Rating (Max. Load) 296 W (50 Hz at 85 Pa) / 369 W (60 Hz at 35 Pa)
Intermediate Curve Power (50 Hz) 262 W (at 30 Pa, Point 2); 280 W (at 60 Pa, Point 3)
Intermediate Curve Power (60 Hz) 358 W (at 20 Pa, Point 2)
Free-Air Current Draw 1.10 A (50 Hz) / 1.53 A (60 Hz) (Nominal at 0 Pa Free Air)
Rated Current (Max. Load) 1.33 A (50 Hz at 85 Pa) / 1.61 A (60 Hz at 35 Pa)
Intermediate Curve Current (50 Hz) 1.19 A (at 30 Pa, Point 2); 1.26 A (at 60 Pa, Point 3)
Intermediate Curve Current (60 Hz) 1.57 A (at 20 Pa, Point 2)
Inrush / Starting Current 2.8 A (50 Hz) / 2.6 A (60 Hz)
Run Capacitor 8 µF, 400 VDB (Safety Protection Class S0 per EN 60252-1)
Capacitor Wiring / Operation Mode Integrated and pre-connected inside terminal box (Continuous Run)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 3,219.8 CFM / 5,471 m³/h (50 Hz at 0 Pa); 3,656.5 CFM / 6,213 m³/h (60 Hz at 0 Pa)
Operating Duty Point Airflow (50 Hz) 2,943.2 CFM (5,001 m³/h) at 0.120 in H₂O (30 Pa, Pt 2); 2,707.2 CFM (4,600 m³/h) at 0.241 in H₂O (60 Pa, Pt 3); 2,404.1 CFM (4,085 m³/h) at 0.341 in H₂O (85 Pa, Pt 4)
Operating Duty Point Airflow (60 Hz) 3,472.9 CFM (5,901 m³/h) at 0.080 in H₂O (20 Pa, Pt 2); 3,332.2 CFM (5,662 m³/h) at 0.141 in H₂O (35 Pa, Pt 3)
Max. Static Pressure 0.341 in H₂O / 85 Pa (50 Hz); 0.141 in H₂O / 35 Pa (60 Hz)
Aerodynamic Test Standard ISO 5801 Installation Category A (Air Density ρ = 1.15 kg/m³ ± 2%, Measurements 10226 & 10294)
Airflow Direction “V” (Intake over Guard Grille / Struts toward Rotor)
Ingress Protection (IP) IP44
Moisture / Environmental Class H1
Operating Temperature -40 °C to +40 °C / -40 °F to +104 °F (50 Hz); -40 °C to +20 °C / -40 °F to +68 °F (60 Hz)
Storage Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Motor & Drive Protection Thermal Overload Protector (TOP) internally connected
Electrical Protection Class Class I (with customer connection of protective earth PE)
Touch Current (IEC 60990) < 0.75 mA (Measuring circuit Fig. 4, TN system)
Insulation Class Class “B”
Termination Type Integrated Terminal Box (4-pole internal terminal strip: U1, Z, U2, PE)
Cable Exit Orientation Variable cable entry via terminal box
Conduit / Cable Gland Ports M16 × 1.5 cable gland (for cable Ø max. 7.5 mm / 0.30 in; gland tightening torque 2 Nm; lid screw torque 0.5 Nm)
Wiring Pinout / Connection L = U1 (Blue), Z (Brown, capacitor lead), N = U2 (Black), PE (Green/Yellow)
Nominal Size 450 mm (17.72 in)
Impeller Size Ø 446 mm (17.56 in)
Outer Dimensions (Ø × D) Ø 522 × 179.8 mm (Ø 20.55 × 7.08 in)
Guard Grille Inner Ring Diameter Ø 475 mm (18.70 in)
Total Axial Depth 179.8 mm (7.08 in)
Guard Grille Axial Depth & Offset 126.5 mm (4.98 in) guard depth / 54.6 mm (2.15 in) terminal box axial overhang
Weight 7.3 kg (16.09 lbs)
Blade Count & Geometry 5 Sickle-Shaped Blades (S Series)
Bearing Type Ball Bearing with Low-Temperature Lubricant
Electronics Housing Material ABS Plastic, Black (Terminal Box)
Impeller / Blade Material Sheet Steel, Painted Black
Guard Grille Material Steel, Phosphated and Coated with Black Plastic
Rotor Surface Painted Black
Direction of Rotation Counterclockwise (CCW), Viewed Toward Rotor
Installation Position Shaft Horizontal or Rotor on Bottom (Rotor on Top on Request)
Condensation Drainage Holes On Rotor Side
Standards & Compliance CCC, IEC 60990, EN 60252-1, ISO 5801, ISO 13347

Applications

ebm-papst S4E450-8317078900 AC axial fan assembly is engineered for heavy-duty commercial refrigeration, walk-in cold storage evaporators, air-cooled refrigeration condensers, and industrial chillers requiring dependable air movement in sub-zero environments. Its short-nozzle guard grille and integrated terminal box enable direct bolt-on installation into rooftop HVAC heat rejection decks, dry coolers, heat pump outdoor units, and blast freezers. Additionally, industrial OEMs and MRO technicians deploy this unit for high-volume forced ventilation across power transformer cooling radiators, generator set enclosures, and factory machinery heat exchangers.