R4E225-AI01-09 ebm-papst 230VAC 225mm AC Centrifugal Fan

$375.00

ebm-papst R4E225-AI01-09 (R4E225AI0109) 230VAC Ø225mm backward-curved centrifugal fan, 1430/1700RPM, 265/315CFM, 40/45W, with 11-blade PA6 impeller & IP44.

SKU: R4E225-AI01-09 Category: Brand:

Description

ebm-papst R4E225-AI01-09 (also known as R4E225AI0109) is an unhoused backward-curved AC centrifugal motorized impeller powered by an integrated M4E068-CF external-rotor motor with a 225 mm (8.86 in) impeller diameter. Operating on single-phase 230 VAC (50/60 Hz) power with a 1.5 µF / 450 VDB run capacitor, this fan achieves free-air speeds of 1430 RPM (50 Hz) and 1700 RPM (60 Hz) while delivering up to 265 CFM (450 m³/h) at 50 Hz and 315 CFM (530 m³/h) at 60 Hz. Its 11-blade glass-fiber reinforced PA6 plastic impeller and ball-bearing motor assembly provide reliable S1 continuous duty across ambient temperatures from -25 °C to +50 °C (-13 °F to +122 °F).

Built with IP44 ingress protection, Class B insulation, and an internally connected thermal overload protector (TOP), the unit terminates via a variable-exit 4G AWG20 PVC cable with 4 crimped splices and carries CE, UL 1004-3, CSA C22.2 No. 77, and CCC certifications.

Key Features

  • Dual-Frequency Aerodynamic Output: Delivers 265 CFM (450 m³/h) at 50 Hz and 315 CFM (530 m³/h) at 60 Hz in free air.
  • Backward-Curved Composite Impeller: Eleven aerodynamically profiled blades molded from glass-fiber reinforced PA6 plastic provide high static efficiency without a scroll housing.
  • Integrated M4E068-CF External-Rotor Motor: Precision ball-bearing motor supports continuous S1 operation in any mounting orientation from -25 °C to +50 °C.
  • Internal Thermal Overload Protection: Built-in TOP sensor, IP44 environmental sealing, and Class I grounded construction safeguard against motor overheating and moisture.
  • Pre-Terminated Industrial Harness: Supplied with a variable-exit 4G AWG20 PVC cable featuring four crimped splices for rapid OEM cabinet integration.
  • Global Multi-Standard Approvals: Certified to CE, EN 60335-1, UL 1004-3,UL 2111, CSA C22.2 No. 77, and CCC for international machinery compliance.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) R4E225-AI01-09
Alternate Part Number R4E225AI0109
OEM Item Number 11655-5-9980
Integrated Motor Model M4E068-CF (Motor Size 68)
Product Series R4E225 Series
Product Category AC Centrifugal Fans
Fan / Component Type Backward-Curved Motorized Impeller (Unhoused Centrifugal Fan)
Motor Design / Technology 4-Pole Single-Phase AC External Rotor Capacitor-Run Motor
Phase & Supply Type 1~ (Single-Phase AC)
Rated Voltage 230 VAC
Frequency 50 / 60 Hz
Free-Air Speed (RPM) 1430 RPM (50 Hz) / 1700 RPM (60 Hz)
Speed under Back Pressure (Curve Point 3) 1425 RPM (50 Hz at 80 Pa) / 1680 RPM (60 Hz at 120 Pa)
Speed under Back Pressure (Curve Point 4) 1425 RPM (50 Hz at 105 Pa) / 1690 RPM (60 Hz at 150 Pa)
Free-Air Power Input (CE) 40 W (50 Hz) / 45 W (60 Hz)
Free-Air Power Input (UL 2111) 50 W (60 Hz)
Power Input under Back Pressure (Peak Curve Load) 41 W (50 Hz at 80–105 Pa) / 49 W (60 Hz at 120 Pa)
Free-Air Current Draw (CE) 0.20 A (50 Hz) / 0.20 A (60 Hz)
Free-Air Current Draw (UL 2111) 0.22 A (60 Hz)
Current Draw under Back Pressure (Peak Curve Load) 0.20 A (50 Hz at 80–105 Pa) / 0.21 A (60 Hz at 120–150 Pa)
Run Capacitor 1.5 µF, 450 VDB
Capacitor Standard S0 (CE) / UL
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 265 CFM / 450 m³/h (50 Hz, Curve Pt 1) / 315 CFM / 530 m³/h (60 Hz, Curve Pt 1)
Operating Duty Point Airflow (Curve Point 2) 220 CFM (370 m³/h) at 0.16 in H₂O (40 Pa, 50 Hz) / 255 CFM (435 m³/h) at 0.24 in H₂O (60 Pa, 60 Hz)
Operating Duty Point Airflow (Curve Point 3) 160 CFM (270 m³/h) at 0.32 in H₂O (80 Pa, 50 Hz) / 175 CFM (300 m³/h) at 0.48 in H₂O (120 Pa, 60 Hz)
Operating Duty Point Airflow (Curve Point 4) 100 CFM (170 m³/h) at 0.42 in H₂O (105 Pa, 50 Hz) / 110 CFM (185 m³/h) at 0.60 in H₂O (150 Pa, 60 Hz)
Max. Static Pressure (Measured Curve Point 4) 0.42 in H₂O / 105 Pa (50 Hz) / 0.60 in H₂O / 150 Pa (60 Hz)
Max. Static Pressure (Shut-Off Curve Limit) 0.54 in H₂O / 135 Pa (50 Hz) / 0.76 in H₂O / 190 Pa (60 Hz)
Min. Back Pressure 0 in H₂O (0 Pa)
Aerodynamic Measurement Category ISO 5801 Installation Category A (Measurement LU-30980-1 at 50 Hz / LU-30981-1 at 60 Hz)
Airflow Direction Axial Intake, Radial Centrifugal Discharge
Ingress Protection (IP) IP44 (Installation- and Position-Dependent)
Moisture / Environmental Class H0 (Dry Environment)
Operating Temperature -25 °C to +50 °C (-13 °F to +122 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Motor & Drive Protection Thermal Overload Protector (TOP) Internally Connected
Electrical Protection Class Class I (With Customer Connection of Protective Earth)
Touch Current (IEC 60990) < 0.75 mA (Measuring Circuit Fig. 4, TN System)
Insulation Class Class B
Termination Type 4-Conductor PVC Cable with 4x Crimped Splices
Cable Exit Orientation Variable
Lead Wire Gauge & Spec PVC 4G AWG20
Wiring Pinout / Connection U1 = Blue, Z = Brown, U2 = Black, PE = Green/Yellow
Impeller Size Ø225 mm (8.86 in)
Max. Screw Clearance 5 mm (0.20 in)
Weight 1.9 kg (4.19 lbs)
Blade Count & Geometry 11 Backward-Curved Blades
Bearing Type Ball Bearing
Impeller / Blade Material Glass-Fiber Reinforced PA6 Plastic
Direction of Rotation Clockwise (Viewed Toward Rotor)
Installation Position Any
Condensation Drainage Holes None
Compatible Inlet Ring (Optional) 96358-2-4013 (Not Included in Scope of Delivery)
Standards & Compliance CE, EN 60335-1, UL 1004-3, UL 2111, CSA C22.2 No. 77, CCC

Applications

ebm-papst R4E225-AI01-09 backward-curved centrifugal motorized impellers are engineered for unhoused plenum pressurization and ducted extraction across commercial HVAC and industrial thermal systems. Typical OEM and MRO installations include precision air handling units (AHUs), heat recovery ventilation (HRV) modules, cleanroom fan filter units (FFUs), and roof or wall exhaust ventilators. They are also widely deployed inside power electronics enclosures, variable frequency drive (VFD) cabinets, medical diagnostic equipment, and industrial drying or process cooling machinery requiring steady airflow against moderate static resistance.