R3G250-AV29-B5 ebm-papst 230VAC 250mm EC Centrifugal Fan

$516.00

ebm-papst R3G250-AV29-B5 (R3G250AV29B5) 230VAC Ø250mm RadiPac EC centrifugal fan, 3450RPM, 1685CFM, 750W, with M3G084-FA motor, MODBUS-RTU & IP54.

SKU: R3G250-AV29-B5 Category: Brand:

Description

ebm-papst R3G250-AV29-B5 (also known as R3G250AV29B5, OEM Item No. 52222-5-9980) is a RadiPac series single-intake, backward-curved motorized EC centrifugal impeller powered by an integrated M3G084-FA electronically commutated motor with a 250 mm (9.84 in) diameter impeller. Operating across a wide single-phase 200 to 277 VAC (230 VAC nominal, 50/60 Hz) supply, it achieves a rated speed of 3450 RPM and delivers up to 1685 CFM (2865 m³/h) of free-air volume flow or 1060 CFM (1800 m³/h) at 3.21 in H₂O (800 Pa) at its 750 W / 3.30 A maximum load point.

Built with a 7-blade sheet aluminum impeller, a black-painted rotor, a die-cast aluminum electronics enclosure, and maintenance-free ball bearings, the unit provides IP54 and F3-1 environmental protection across an ambient operating range of -25 °C to +40 °C (-13 °F to +104 °F). Its internal SELV terminal strip supports RS-485 MODBUS-RTU networking, 0–10 VDC / PWM speed control, 0–10 V or 4–20 mA sensor feedback, an active PFC circuit, and a floating changeover alarm relay.

Key Features

  • RadiPac Backward-Curved Aerodynamics: 7-blade 250 mm sheet aluminum impeller delivers 1685 CFM free-air flow and 4.01 in H₂O (1000 Pa) curve pressure.
  • Wide-Range Active PFC EC Drive: Integrated M3G084-FA motor runs on 1~ 200–277 VAC (50/60 Hz) with active power factor correction and soft start.
  • RS-485 MODBUS-RTU & Analog Control: SELV interface supports MODBUS-RTU, 0–10 VDC/PWM control, 0–10 V or 4–20 mA sensor inputs, and slave output.
  • Onboard Auxiliary Power & Relay: Provides +10 VDC (10 mA) and +20 VDC (50 mA) sensor supplies plus a 250 VAC / 2 A changeover status relay.
  • ErP Directive High Efficiency: Achieves 59.1% static efficiency (Grade N = 70.9) at 1030.0 CFM (1750 m³/h) and 3.35 in H₂O (833 Pa).
  • Comprehensive Drive Protection: Equipped with internal TOP thermal overload protection, motor current limitation, and line undervoltage or phase failure detection.
  • IP54 Industrial Construction: Die-cast aluminum electronics housing, ball bearings, F3-1 moisture rating, and rotor-side condensation drainage holes ensure reliability.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) R3G250-AV29-B5
Alternate Part Number R3G250AV29B5
OEM Item Number 52222-5-9980
Integrated Motor Model M3G084-FA
Product Series RadiPac (R3G Series)
Product Category EC Centrifugal Fans
Fan / Component Type Backward-Curved Single-Intake Motorized EC Impeller
Motor Design / Technology Electronically Commutated (EC) External Rotor Motor with Integrated Electronics
Phase & Supply Type 1~ (Single-Phase AC Input)
Rated Voltage 230 VAC
Operating Voltage Range 200 to 277 VAC
Frequency 50 / 60 Hz
Speed (Max. Load) 3450 RPM
Free-Air Speed (RPM) 3450 RPM
ErP Optimum Speed (RPM) 3445 RPM
Power Rating (Max. Load) 750 W (at Pt. 3: 1800 m³/h, 800 Pa)
Free-Air Power Input 618 W (at Pt. 1: 2865 m³/h, 0 Pa)
Intermediate Curve Power Input 734 W (Pt. 2 at 400 Pa); 705 W (Pt. 4 at 1000 Pa)
ErP Optimum Efficiency Power 750 W (0.75 kW at 1750 m³/h, 833 Pa)
Part-Load Speed Curve Power Input 388 to 493 W (at 3000 RPM); 225 to 285 W (at 2500 RPM); 115 to 146 W (at 2000 RPM)
Rated Current (Max. Load) 3.30 A (at Pt. 3: 1800 m³/h, 800 Pa)
Free-Air Current Draw 2.74 A (at Pt. 1: 2865 m³/h, 0 Pa)
Intermediate Curve Current Draw 3.24 A (Pt. 2 at 400 Pa); 3.12 A (Pt. 4 at 1000 Pa)
Part-Load Speed Curve Current Draw 1.72 to 2.18 A (at 3000 RPM); 0.99 to 1.26 A (at 2500 RPM); 0.51 to 0.65 A (at 2000 RPM)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 1685 CFM (2865 m³/h) at 0 Pa (3450 RPM, Pt. 1)
Operating Duty Point Airflow (3450 RPM) 1450 CFM (2465 m³/h) at 1.61 in H₂O (400 Pa, Pt. 2); 1060 CFM (1800 m³/h) at 3.21 in H₂O (800 Pa, Pt. 3 Max. Load); 705 CFM (1200 m³/h) at 4.01 in H₂O (1000 Pa, Pt. 4)
Operating Duty Point Airflow (3000 RPM) 1445 CFM (2450 m³/h) at 0 Pa (Pt. 5); 1260 CFM (2140 m³/h) at 1.22 in H₂O (305 Pa, Pt. 6); 920 CFM (1565 m³/h) at 2.44 in H₂O (609 Pa, Pt. 7); 605 CFM (1030 m³/h) at 2.97 in H₂O (739 Pa, Pt. 8)
Operating Duty Point Airflow (2500 RPM) 1200 CFM (2045 m³/h) at 0 Pa (Pt. 9); 1050 CFM (1780 m³/h) at 0.85 in H₂O (212 Pa, Pt. 10); 770 CFM (1305 m³/h) at 1.70 in H₂O (423 Pa, Pt. 11); 505 CFM (860 m³/h) at 2.06 in H₂O (513 Pa, Pt. 12)
Operating Duty Point Airflow (2000 RPM) 960 CFM (1635 m³/h) at 0 Pa (Pt. 13); 840 CFM (1425 m³/h) at 0.54 in H₂O (135 Pa, Pt. 14); 615 CFM (1045 m³/h) at 1.09 in H₂O (271 Pa, Pt. 15); 405 CFM (690 m³/h) at 1.32 in H₂O (328 Pa, Pt. 16)
ErP Optimum Efficiency Duty Point 1030.0 CFM (1750 m³/h) at 3.35 in H₂O (833 Pa)
Max. Static Pressure (Measured Table) 4.01 in H₂O (1000 Pa) at 705 CFM (1200 m³/h, Pt. 4)
Sound Pressure Level (Max. Load) 73 dB(A) (Intake side at 1 m, Pt. 3: 800 Pa)
Free-Air Sound Pressure Level 79 dB(A) (Intake side at 1 m, Pt. 1: 0 Pa)
Intermediate Curve Sound Pressure Level 76 dB(A) (Pt. 2 at 400 Pa); 74 dB(A) (Pt. 4 at 1000 Pa); 59 to 75 dB(A) (across 2000–3000 RPM curves)
Sound Power Level (Max. Load) 81 dB(A) (Intake side per ISO 13347, Pt. 3: 800 Pa)
Free-Air Sound Power Level 87 dB(A) (Intake side per ISO 13347, Pt. 1: 0 Pa)
Intermediate Curve Sound Power Level 84 dB(A) (Pt. 2 at 400 Pa); 82 dB(A) (Pt. 4 at 1000 Pa); 67 to 83 dB(A) (across 2000–3000 RPM curves)
ErP Efficiency & Grade (EU 327/2011) Overall Static Efficiency ηes = 59.1% (Req. 2015: 50.2%); Efficiency Grade N = 70.9 (Req: 62); Measurement Category A; Efficiency Category Static; Specific Ratio = 1.01; Integrated VSD (LU-141280)
Ingress Protection (IP) IP54
Moisture / Environmental Class F3-1
Operating Temperature -25 °C to +40 °C (-13 °F to +104 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Motor & Drive Protection Internally Connected Thermal Overload Protector (TOP) for Electronics/Motor, Motor Current Limitation, Active PFC, Soft Start, Line Undervoltage / Phase Failure Detection
Electrical Protection Class Class I (with customer connection of protective earth)
Touch Current (IEC 60990) <= 3.5 mA (Measuring circuit Fig. 4, TN system)
Insulation Class Class B
Control / Signal Features RS-485 MODBUS-RTU, 0–10 VDC / PWM Control Input, 0–10 V or 4–20 mA Sensor Input, 0–10 V Slave Output, +10 VDC & +20 VDC Auxiliary Outputs, CW/CCW Rotation Selection, Floating Changeover Alarm Relay, SELV Interface
Termination Type Internal Terminal Blocks (PE, KL1, KL2, KL3)
Cable Gland Diameter & Torque Cable Diameter: Min. 4 mm (0.16 in), Max. 10 mm (0.39 in); Gland Tightening Torque: 2.5 ± 0.4 Nm
Terminal Cover Tightening Torque 3.5 ± 0.5 Nm
Power & Relay Terminal Pinout (PE, KL1, KL2) PE: Protective earth; KL1-1/2 (N, L): Power supply 50/60 Hz; KL2-1 (NC): Status contact break for failure; KL2-2 (COM): Common (2 A, max. 250 VAC, min. 10 mA, AC1); KL2-3 (NO): Status contact make for failure
Control & MODBUS Terminal Pinout (KL3) KL3-1 (OUT): 0–10 VDC modulation output (max. 3 mA, 1 V = 10%, 10 V = 100%); KL3-2,8 (GND): SELV reference ground; KL3-3,7 (0–10 V): Control/sensor input (100 kΩ); KL3-4 (+10 V): 10 VDC ±3% output (max. 10 mA); KL3-5 (+20 V): 20 VDC +25%/-10% output (max. 50 mA); KL3-6 (4–20 mA): Control/sensor input (100 Ω); KL3-9,11 (RSB) & KL3-10,12 (RSA): RS-485 MODBUS-RTU
Impeller Size Ø 250 mm (9.84 in)
Max. Screw Clearance 16 mm (0.63 in)
Weight 5.6 kg (12.35 lbs)
Blade Count & Geometry 7 Backward-Curved Blades (Single-Intake)
Bearing Type Ball Bearing
Electronics Housing Material Die-Cast Aluminum
Impeller / Blade Material Sheet Aluminum
Rotor Surface Painted Black
Direction of Rotation Clockwise, Viewed Toward Rotor (Selectable Left/Right via Control Interface)
Installation Position Shaft Horizontal or Rotor on Bottom (Rotor on Top on Request)
Condensation Drainage Holes On Rotor Side
Compatible Inlet Ring (Optional) Part No. 25075-2-4013 with Pressure Tap (k-factor: 70, Not Included in Scope of Delivery)
EMC Standards EN 61000-6-2 (Industrial Immunity), EN 61000-3-2/3 (Circuit Feedback), EN 55022 Class B (Household Interference Emission)
Standards & Compliance EN 61800-5-1, CE, ISO 5801 (Installation Category A), ISO 13347

Applications

ebm-papst R3G250-AV29-B5 RadiPac backward-curved EC centrifugal impellers are engineered for pressurized plenum air handling and precision thermal management in commercial HVAC and industrial facilities. Typical installations include data center CRAC and CRAH cooling units, modular air handling units (AHUs), cleanroom Fan Filter Units (FFUs), and building heat recovery ventilation (HRV) systems where variable demand control and high static efficiency are mandatory. Its integrated MODBUS-RTU communication, direct sensor feedback inputs, and moisture-resistant construction also make it a direct drop-in replacement for automated industrial process cooling and power electronics enclosures.