ebm-papst A2D170-AA04-02 (A2D170AA0402) 230/400VAC 170mm 3-phase axial fan, 2750/3100RPM, 314.9CFM (535m³/h), 45/43W, with 6 aluminum blades & M2D068-BF motor.

SKU: A2D170-AA04-02 Category: Brand:

Description

ebm-papst A2D170-AA04-02 (also known as A2D170AA0402) is an industrial three-phase AC axial cooling fan built around the M2D068-BF external rotor motor with a 170 mm (6.69 in) impeller diameter and 62.5 mm (2.46 in) profile depth. Supporting dual-voltage 230 VAC Delta (Δ) and 400 VAC Star (Y) connections across 50/60 Hz supplies, it delivers a nominal free-air speed of 2750 RPM (50 Hz) / 3100 RPM (60 Hz) at 45 W / 43 W input power, reaching 314.89 CFM (535 m³/h) at 60 Hz free air and up to 0.321 in H₂O (80 Pa) along its measured operating curve.

Engineered for continuous S1 operation in demanding thermal environments from -25 °C to +70 °C (-13 °F to +158 °F at 60 Hz), it features six die-cast aluminum blades, a black-coated rotor, ball bearings, IP44 protection, and a lateral PVC 7G 0.5 mm² lead cable with crimped brass tips.

Key Features

  • Dual-Voltage 3-Phase Motor: Integrated M2D068-BF motor supports 230 VAC Delta (Δ) and 400 VAC Star (Y) 50/60 Hz operation.
  • High-Velocity Axial Airflow: Delivers 314.89 CFM (535 m³/h) free-air flow at 3100 RPM (60 Hz) with curve duties up to 80 Pa.
  • Rugged Metallic Impeller: Six die-cast aluminum blades paired with a black-coated external rotor ensure structural stability under thermal stress.
  • Industrial IP44 & Ball Bearings: Precision ball bearings and IP44 ingress protection enable continuous S1 duty in any mounting orientation.
  • Pre-Terminated 7-Core Harness: Lateral PVC 7G 0.5 mm² cable with 7 crimped brass lead tips simplifies Delta/Star motor wiring.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) A2D170-AA04-02
Alternate Part Number A2D170AA0402
OEM Item Number 11074-5-9980 (Revision 72138)
Integrated Motor Model M2D068-BF
Product Category AC Axial Fans
Fan / Component Type 3-Phase AC Tubeaxial Fan (Unhoused Impeller Assembly)
Motor Design / Technology 3-Phase AC External Rotor Induction Motor
Phase & Supply Type 3-Phase AC (3~), Dual-Voltage Delta (Δ) / Star (Y)
Rated Voltage 230 VAC (Delta Δ) / 400 VAC (Star Y)
Frequency 50 / 60 Hz
Free-Air Speed (RPM) 2750 RPM (50 Hz) / 3100 RPM (60 Hz)
Speed (Max. Curve Point 4 at 80 Pa) 3000 RPM (400 VAC, 60 Hz)
Curve Operating Speed (Points 2 & 3) 3065 RPM at 30 Pa / 3015 RPM at 60 Pa (400 VAC, 60 Hz)
Free-Air Power Input (Nominal) 45 W (50 Hz) / 43 W (60 Hz)
Measured Curve Power Input (400 VAC, 60 Hz) 39 W (Point 1 at 0 Pa), 41 W (Point 2 at 30 Pa), 43 W (Point 3 at 60 Pa), 44 W (Point 4 at 80 Pa)
Free-Air Current Draw (230 VAC Delta Δ) 0.23 A (50 Hz) / 0.16 A (60 Hz)
Free-Air Current Draw (400 VAC Star Y) 0.13 A (50 Hz) / 0.09 A (60 Hz)
Inrush / Starting Current (230 VAC Delta Δ) 0.40 A (50 Hz) / 0.38 A (60 Hz)
Inrush / Starting Current (400 VAC Star Y) 0.23 A (50 Hz) / 0.22 A (60 Hz)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air at 60 Hz) 314.89 CFM (535 m³/h at 400 VAC, 60 Hz, 0 Pa, Measurement LU-25209)
Nominal Airflow Range (50 / 60 Hz) 288.40 CFM (490 m³/h at 50 Hz) / 314.89 CFM (535 m³/h at 60 Hz)
Operating Duty Point Airflow (Point 2) 291.35 CFM (495 m³/h) at 0.120 in H₂O (30 Pa, 400 VAC, 60 Hz)
Operating Duty Point Airflow (Point 3) 264.86 CFM (450 m³/h) at 0.241 in H₂O (60 Pa, 400 VAC, 60 Hz)
Operating Duty Point Airflow (Point 4) 217.78 CFM (370 m³/h) at 0.321 in H₂O (80 Pa, 400 VAC, 60 Hz)
Max. Static Pressure (Measured Table Point 4) 0.321 in H₂O (80 Pa at 217.78 CFM / 370 m³/h)
Max. Static Pressure (Chart Shut-Off Curve) 1.00 in H₂O (250 Pa at 0 CFM, 60 Hz P-Q Curve Axis)
Airflow Direction Direction “A” (Axial)
Ingress Protection (IP) IP44 (Depending on installation and position)
Moisture / Environmental Class F0
Operating Temperature (50 Hz) -25 °C to +55 °C (-13 °F to +131 °F)
Operating Temperature (60 Hz) -25 °C to +70 °C (-13 °F to +158 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Electrical Protection Class Class I (with customer-connected protective earth)
Touch Current (IEC 60990) < 0.75 mA (Measuring network Fig. 4, TN system)
Insulation Class Class “B”
Termination Type 7 Wire Leads with 7x crimped brass lead tips
Cable Exit Orientation Lateral
Lead Wire Gauge & Spec PVC 7G 0.5 mm² (7 cores including protective earth)
Wiring Pinout / Connection Delta (Δ 230 VAC) / Star (Y 400 VAC): L1 / U1 = Black, L2 / V1 = Blue, L3 / W1 = Brown, U2 = Green, V2 = White, W2 = Yellow (Direction of rotation reverses when two phases are swapped)
Impeller Size Ø 170 mm (6.69 in)
Outer Dimensions (Ø × D) Ø 170 × 62.5 mm (Ø 6.69 × 2.46 in)
Max. Screw Clearance 5 mm (0.20 in) max. screw depth
Weight 1.2 kg (2.65 lbs)
Blade Count & Geometry 6 Axial Blades
Bearing Type Ball Bearing
Impeller / Blade Material Die-Cast Aluminium
Rotor Surface Coated in black
Direction of Rotation Clockwise, seen on rotor
Installation Position Any
Condensation Drainage Holes None
Standards & Compliance CE, CCC, EN 60335-1, ISO 5801 (Cat. A), ISO 13347
RoHS / Environmental Compliance RoHS3 Compliant

Applications

ebm-papst A2D170-AA04-02 three-phase AC axial fan is engineered for high-reliability forced-air thermal management across industrial power electronics, automation cabinets, and commercial refrigeration machinery. Its die-cast aluminum impeller and dual-voltage Delta/Star motor architecture make it directly suited for variable frequency drives (VFDs), servo drive racks, CNC machine tool enclosures, welding power sources, and UPS inverter assemblies. In OEM manufacturing and MRO field replacement, this unit provides continuous heat dissipation inside compact heat exchangers, chiller condensers, and industrial control switchgear.