W2S130-AA03-87 ebm-papst 230VAC 150x55mm AC Axial Fan

$211.50

ebm-papst W2S130-AA03-87 (W2S130AA0387) 230VAC Ø150x55mm AC axial fan, 2800/3250RPM, 200/230CFM, 45/39W, with Hall IC speed sensor, ball bearings & TOP.

SKU: W2S130-AA03-87 Category: Brand:

Description

ebm-papst W2S130-AA03-87 (also known as W2S130AA0387) is an S-series AC axial compact fan powered by an integrated M2S052-CA shaded-pole motor within a Ø 150 × 55 mm (5.91 × 2.17 in) round die-cast aluminum housing with a 130 mm (5.12 in) 7-blade sickle-shaped steel impeller. Operating on single-phase 230 VAC (50/60 Hz) power, it delivers a free-air speed of 2800 RPM (50 Hz) / 3250 RPM (60 Hz) at 45 W / 39 W (0.31 A / 0.25 A), producing up to 200 CFM (340 m³/h) at 50 Hz and 230 CFM (390 m³/h) at 60 Hz with a maximum static back pressure of 0.32 in H₂O (80 Pa) / 0.48 in H₂O (120 Pa).

Engineered for continuous S1 industrial duty from -25 °C to +50 °C (50 Hz) or +70 °C (60 Hz), this unit features an integrated 5 V Hall IC tachometer output for closed-loop speed monitoring, precision ball bearings, an internally connected thermal overload protector (TOP), and dual PVC cable harnesses for power and sensor signaling.

Key Features

  • Dual-Frequency Aerodynamic Output: Delivers 200 CFM (340 m³/h) at 50 Hz and 230 CFM (390 m³/h) at 60 Hz.
  • Integrated Hall IC Speed Monitoring: Dedicated 3-wire AWG 26 Hall sensor circuit (+5 V, output, GND) provides real-time tachometer feedback.
  • Heavy-Duty All-Metal Construction: Combines a black-painted die-cast aluminum round housing with a 7-blade sickle-shaped sheet steel impeller.
  • Internal Thermal Overload Protection: Built-in TOP sensor and ball bearing system support continuous S1 operation up to +70 °C at 60 Hz.
  • Global Safety & EMC Approvals: Certified to UL 507, CSA C22.2 No. 113, EN 60335-1, CE, CCC, and EAC standards.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) W2S130-AA03-87
Alternate Part Number W2S130AA0387
OEM Item Number 10431-5-9980 (Change 86000)
Integrated Motor Model M2S052-CA
Product Series W2S130 (S Series Sickle-Blade Compact Axial)
Product Category AC Axial Fans
Fan / Component Type AC Axial Compact Fan (Round Housing)
Phase & Supply Type 1~ (Single-Phase AC)
Rated Voltage 230 VAC
Frequency 50 / 60 Hz
Free-Air Speed (RPM) 2800 RPM (50 Hz) / 3250 RPM (60 Hz)
Speed (Max. Curve Load) 2780 RPM (50 Hz at 55 Pa) / 3145 RPM (60 Hz at 70 Pa)
Free-Air Power Input 45 W (50 Hz) / 39 W (60 Hz)
Power Rating (Max. Curve Load) 46 W (50 Hz at 55 Pa) / 44 W (60 Hz at 70 Pa)
Free-Air Current Draw 0.31 A (50 Hz) / 0.25 A (60 Hz)
Rated Current (Max. Curve Load) 0.31 A (50 Hz at 55 Pa) / 0.26 A (60 Hz at 70 Pa)
Inrush / Starting Current 0.45 A (50 Hz) / 0.40 A (60 Hz)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 200 CFM / 340 m³/h (50 Hz at 0 Pa) ; 230 CFM / 390 m³/h (60 Hz at 0 Pa)
Operating Duty Point Airflow (50 Hz) Pt 2: 180 CFM (305 m³/h) at 0.08 in H₂O (20 Pa) ; Pt 3: 155 CFM (265 m³/h) at 0.16 in H₂O (40 Pa) ; Pt 4: 120 CFM (200 m³/h) at 0.22 in H₂O (55 Pa)
Operating Duty Point Airflow (60 Hz) Pt 2: 210 CFM (355 m³/h) at 0.10 in H₂O (25 Pa) ; Pt 3: 180 CFM (305 m³/h) at 0.20 in H₂O (50 Pa) ; Pt 4: 135 CFM (235 m³/h) at 0.28 in H₂O (70 Pa)
Max. Static Pressure 0.32 in H₂O / 80 Pa (50 Hz) ; 0.48 in H₂O / 120 Pa (60 Hz)
Air Performance Measurement Setup ISO 5801 Installation Category A (Air Density ρ = 1.15 kg/m³ ± 2%, LU-58475-1 / LU-58476-1)
Sound Pressure Level 53.0 dB(A)
Airflow Direction “V” (Intake over struts / Exhaust over rotor)
Ingress Protection (IP) IP20
Operating Temperature -25 °C to +50 °C / -13 °F to +122 °F (50 Hz) ; -25 °C to +70 °C / -13 °F to +158 °F (60 Hz)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Motor & Drive Protection Thermal Overload Protector (TOP) internally connected
Electrical Protection Class Class I (with customer protective earth connected to housing M4 ground point)
Touch Current (IEC 60990) < 0.75 mA (Measuring circuit Fig. 4, TN system)
Insulation Class Class “B”
Control / Signal Features Speed Monitoring Hall IC (with basic insulation)
Termination Type 5 Wire Leads (2-wire Power Cable + 3-wire Hall Sensor Cable) & M4 Grounding Screw
Lead Wire Gauge & Spec Power Cable: PVC AWG 20 with 2x crimped splices ; Hall IC Cable: PVC AWG 26 with tin-plated wire ends
Power Wiring Pinout (Cable 1) L (Phase): Black ; N (Neutral): Black ; PE (Protective Earth): M4 screw on housing
Control & Signal Pinout (Cable 2) Hall IC Supply (+5 V): Red ; Tachometer Signal Output (out): White ; Ground (0 V): Black
Impeller Size Ø 130 mm (5.12 in)
Outer Dimensions (Ø × D) Ø 150 × 55 mm (Ø 5.91 × 2.17 in)
Housing Section Width 55.0 mm (2.17 in)
Mounting Hole Diameter / Thread Size M4 screw for fastening ground connector
Weight 1.05 kg (2.31 lbs)
Blade Count & Geometry 7 Sickle-Shaped Blades (S Series)
Bearing Type Ball Bearing
Housing / Scroll / Frame Material Die-cast aluminum, painted black
Impeller / Blade Material Sheet steel, painted black
Rotor Surface Open rotor, painted black
Direction of Rotation Counterclockwise, viewed toward rotor
Installation Position Any
Condensation Drainage Holes None (Open rotor)
Standards & Compliance EN 60335-1, CE, UL 507, CSA C22.2 No. 113, CCC, EAC
RoHS / Environmental Compliance RoHS3 Compliant

Applications

ebm-papst W2S130-AA03-87 AC axial compact fans provide monitored forced-air cooling for industrial power electronics, automation enclosures, and thermal processing machinery where closed-loop fan speed verification is required. Common OEM and MRO installations include variable frequency drives (VFDs), servo amplifier cabinets, uninterruptible power supplies (UPS), industrial welding inverters, CNC machine tool control panels, and commercial refrigeration condensers. Its die-cast aluminum housing, steel sickle-blade impeller, and integrated Hall IC tachometer interface ensure dependable thermal management in continuous-duty factory and switchgear environments.