8556N ebm-papst 230VAC 80x80x38mm AC Axial Cooling Fan

$71.51

ebm-papst 8556N 230VAC 80x80x38mm AC axial fan, 2800/3300RPM, 27.1/32.4CFM (46/55m³/h), 12/11W, featuring all-metal housing & impeller and ball bearings.

SKU: 8556N Category: Brand:

Description

ebm-papst 8556N (OEM Item Number 9274014210, specification VWC0080AQHCS) is an industrial 8000N series tubeaxial cooling fan constructed with an all-metal wall-ring housing and metal impeller in a compact 80.0 × 80.0 × 38.0 mm (3.15 × 3.15 × 1.50 in) frame. Operating on a single-phase 230 VAC (50 / 60 Hz) supply, this unit runs at 2800 RPM (50 Hz) / 3300 RPM (60 Hz) while consuming 12 W (50 Hz) / 11 W (60 Hz) to deliver 27.07 CFM (46.0 m³/h) at 50 Hz / 32.37 CFM (55.0 m³/h) at 60 Hz of free-air airflow and up to 0.201 in H₂O (50 Pa) / 0.273 in H₂O (68 Pa) of static pressure.

Engineered for high-temperature reliability from -40 °C to +90 °C (50 Hz) / +95 °C (60 Hz), it features spring-preloaded precision ball bearings for any-orientation shaft mounting, impedance locked-rotor protection, Protection Class I grounding, and a 310 mm (12.20 in) dual 22 AWG lead wire harness encased in a 270 mm protective sleeve.

Key Features

  • Dual-Frequency Aerodynamic Output: Delivers 27.07 CFM (46.0 m³/h) at 50 Hz and 32.37 CFM (55.0 m³/h) at 60 Hz free air.
  • All-Metal Mechanical Construction: Rugged metal wall-ring housing and metal impeller provide structural rigidity and high thermal endurance.
  • Extended High-Temperature Envelope: Operates reliably from -40 °C up to +90 °C (50 Hz) and +95 °C (60 Hz) ambient.
  • Spring-Preloaded Ball Bearings: Play-free ball bearing system supports universal shaft mounting orientation and 55,000-hour L10 life at 40 °C.
  • Impedance Locked-Rotor Protection: Inherently limits stall current under locked-rotor conditions while meeting UL, CSA, VDE, CE, and CCC standards.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) 8556N
OEM Item Number 9274014210 / VWC0080AQHCS (8556 N)
Product Series 8000N
Product Category AC Axial Fans
Fan / Component Type AC Tubeaxial Fan with Wall Ring
Phase & Supply Type 1-Phase AC
Rated Voltage 230 VAC
Operating Voltage Range 207 to 243.8 VAC (+6% / -10%)
Max. Permissible Voltage 230 VAC at 60 Hz (Approval Max. at 95 °C)
Frequency 50 / 60 Hz
Free-Air Speed (RPM) 2800 RPM ±3% (50 Hz) / 3300 RPM ±3% (60 Hz)
Free-Air Power Input 12 W +5%/-10% (50 Hz) / 11 W +5%/-10% (60 Hz)
Airflow (Max. Free Air) 27.07 CFM (46.0 m³/h) at 50 Hz / 32.37 CFM (55.0 m³/h) at 60 Hz
Operating Duty Point Airflow 18.83 CFM (32.0 m³/h) at 0.060 in H₂O (15 Pa) [50 Hz] / 22.95 CFM (39.0 m³/h) at 0.088 in H₂O (22 Pa) [60 Hz]
Max. Static Pressure 0.201 in H₂O (50 Pa) at 50 Hz / 0.273 in H₂O (68 Pa) at 60 Hz
Free-Air Sound Pressure Level 31.0 dB(A) (50 Hz) / 35.0 dB(A) (60 Hz) (at 1 m intake distance)
Sound Power Level (Optimal Point) 4.5 bel(A) [45 dB(A)] (50 Hz) / 5.0 bel(A) [50 dB(A)] (60 Hz) (per DIN 45635-38 / ISO 10302)
Airflow Direction Air Outlet Over Struts
Operating Temperature -40 to 90 °C (-40 to 194 °F) at 50 Hz / -40 to 95 °C (-40 to 203 °F) at 60 Hz
Storage Temperature -40 to 100 °C (-40 to 212 °F)
Operating Humidity Constant humid heat per DIN EN 60068-2-78 (14 days)
Pollution Degree Pollution Degree 1 (per DIN EN 60664-1)
Service Life L10 (at 40 °C) 52,500 hours (50 Hz) / 55,000 hours (60 Hz)
Service Life L10 (at Max. Temp) 15,000 hours at 90 °C (50 Hz) / 15,000 hours at 95 °C (60 Hz)
Motor & Drive Protection Impedance Locked-Rotor Protection
Electrical Protection Class Protection Class I
Insulation Resistance > 50 MΩ (at 500 VDC for 1 min after 48h at 95% RH, 25 °C)
Dielectric Strength 1500 VAC for 1 min (Type Test) / 1500 VAC for 1 sec (Routine Test) per DIN EN 60950 & DIN EN 60335
Clearance / Creepage Distance 2.0 mm (0.079 in) / 1.8 mm (0.071 in)
Termination Type 2 Wire Leads (Tinned Ends, VZ) in Protective Tube
Lead Wire Gauge & Spec 22 AWG (Insulation Diameter: 1.09 mm / 0.043 in)
Cable / Lead Length 310.0 ± 10.0 mm (12.20 ± 0.39 in)
Protective Tube Length 270.0 ± 10.0 mm (10.63 ± 0.39 in)
Wiring Pinout / Connection Wire 1 (Blue): L (Line) | Wire 2 (Blue): N (Neutral)
Dimensions (L × H × D) 80.0 × 80.0 × 38.0 mm (3.15 × 3.15 × 1.50 in)
Mounting Hole Thread / Screw Size ISO 4762 M4 (degreased, without brace/washer) or 8-32 UNC
Max. Mounting Torque 50 Ncm (4.43 lbf·in) across both mounting flanges (wire outlet & remaining corners)
Weight 0.380 kg (0.838 lbs / 380 g)
Bearing Type Ball Bearing (Spring-Preloaded, Axial Play-Free)
Balance Quality G 2.5
Housing / Scroll / Frame Material Metal
Impeller / Blade Material Metal
Direction of Rotation Clockwise (Looking at Rotor)
Installation Position Any Shaft Orientation
Standards & Compliance CE, UL 507 (File E38324), CSA C22.2 No. 113, VDE (EN 60950 / VDE 0805), CCC (GB 12350), EAC, DIN EN ISO 5801, DIN 7167, DIN ISO 2768-mK
RoHS / Environmental Compliance RoHS3 Compliant

Applications

ebm-papst 8556N AC tubeaxial cooling fan is engineered for continuous-duty forced-air ventilation in compact industrial enclosures and heat-intensive electronic subsystems. Its rugged all-metal housing and metal impeller make it well suited for variable frequency drives (VFDs), servo amplifiers, PLC automation racks, CNC machine tool control cabinets, and power supply rectifiers operating in elevated ambient temperatures. OEM builders and MRO technicians deploy this unit in laboratory ovens, welding inverters, telecommunications bays, and industrial switchgear where multi-agency safety approvals and multi-axis mounting flexibility are required.