R3G500-8317081581 ebm-papst 400VAC 500mm EC Centrifugal Fan

$1,899.00

ebm-papst R3G500-8317081581 (R3G5008317081581) 400VAC Ø500mm RadiCal EC centrifugal fan, 1900RPM, 8610CFM, 2850W, with M3G150-FF motor, MODBUS-RTU & IP55.

SKU: R3G500-8317081581 Category: Brand:

Description

ebm-papst R3G500-8317081581 (also known as R3G5008317081581, OEM item number 8317081581) is a single-intake, backward-curved RadiCal EC motorized centrifugal impeller engineered around an integrated M3G150-FF motor and a 500 mm (19.69 in) 6-blade polypropylene impeller. Operating on a 3-phase 400 VAC (380 to 480 VAC, 50/60 Hz) supply, this high-capacity unit runs at a nominal speed of 1900 RPM, drawing 2850 W and 4.40 A at maximum load while delivering up to 8610 CFM (14625 m³/h) of free-air airflow and up to 3.61 in H₂O (900 Pa) of static pressure.

Built for demanding industrial environments, it combines a die-cast aluminum electronics housing, a black painted rotor with maintenance-free ball bearings, and an IP55 / Class H1 environmental rating. An integrated terminal box provides SELV-isolated RS-485 MODBUS-RTU V6.0 communication, parameterizable analog/digital I/O, a floating status relay, and NFC/RFID wireless configuration.

Key Features

  • High-Output RadiCal Aerodynamics: Six-blade 500 mm backward-curved PP plastic impeller delivers 8610 CFM (14625 m³/h) free air and 900 Pa pressure.
  • Wide-Range 3-Phase EC Drive: Integrated M3G150-FF EC motor operates across 380–480 VAC (50/60 Hz) at 1900 RPM with 2850 W max-load rating.
  • RS-485 MODBUS-RTU & RFID Control: Features MODBUS V6.0 protocol, ISO 15693 RFID parameterization, integrated PI controller, and configurable analog/digital I/O.
  • Auxiliary Supply & Status Relay: Includes a parameterizable 3.3–24 VDC (800 mW) output, 15–50 VDC offline parameterization input, and 250 VAC / 2 A fault relay.
  • Comprehensive Drive Protection: Equipped with soft start, motor current limitation, thermal overload protection, phase failure detection, and locked-rotor safeguard.
  • Rugged IP55 & H1 Construction: Die-cast aluminum electronics enclosure, black painted rotor, Class F insulation, and rotor-side condensation drainage holes.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) R3G500-8317081581
Alternate Part Number R3G5008317081581
OEM Item Number 8317081581
Integrated Motor Model M3G150-FF (Motor Size 150)
Product Series RadiCal (R3G Series)
Product Category EC Centrifugal Fans
Fan / Component Type Backward-Curved Motorized Centrifugal Impeller (Single-Intake, Unhoused)
Motor Design / Technology Electronically Commutated (EC) External Rotor Motor with Integrated Electronics
Phase & Supply Type 3~ (3-Phase AC Input)
Rated Voltage 400 VAC
Operating Voltage Range 380 to 480 VAC
Frequency 50 / 60 Hz
Speed (Max. Load) 1900 RPM (Curve Points 2, 3 & 4)
Free-Air Speed (RPM) 1900 RPM (Curve Point 1 at 0 Pa)
Reduced Curve Operating Speeds 1600 RPM (Points 5–8), 1300 RPM (Points 9–12), 1000 RPM (Points 13–16)
Power Rating (Max. Load) 2850 W (Nominal at 1900 RPM, Point 3)
Free-Air Power Input 1648 W (at 1900 RPM, 0 Pa, Point 1)
Intermediate Duty Power Input 2479 W (Point 2 at 400 Pa), 2627 W (Point 4 at 900 Pa)
Reduced-Speed Power Input Range 976 to 1685 W (at 1600 RPM), 524 to 904 W (at 1300 RPM), 238 to 411 W (at 1000 RPM)
Rated Current (Max. Load) 4.40 A (Nominal at 1900 RPM, Point 3)
Free-Air Current Draw 2.61 A (at 1900 RPM, 0 Pa, Point 1)
Intermediate Duty Current Draw 3.83 A (Point 2 at 400 Pa), 4.05 A (Point 4 at 900 Pa)
Reduced-Speed Current Draw Range 1.55 to 2.59 A (at 1600 RPM), 0.83 to 1.39 A (at 1300 RPM), 0.38 to 0.63 A (at 1000 RPM)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 8610 CFM (14625 m³/h) at 0 Pa (0.00 in H₂O), 1900 RPM (Point 1)
Operating Duty Point Airflow (Point 2) 7165 CFM (12170 m³/h) at 1.61 in H₂O (400 Pa), 1900 RPM
Operating Duty Point Airflow (Point 3 – Max. Load) 5415 CFM (9200 m³/h) at 3.01 in H₂O (750 Pa), 1900 RPM
Operating Duty Point Airflow (Point 4 – Peak Curve Pressure) 3600 CFM (6120 m³/h) at 3.61 in H₂O (900 Pa), 1900 RPM
Reduced-Speed Airflow (1600 RPM Curve) 7230 CFM (12285 m³/h) at 0 Pa; 6015 CFM (10225 m³/h) at 1.14 in H₂O (285 Pa); 4550 CFM (7725 m³/h) at 2.12 in H₂O (528 Pa); 3025 CFM (5140 m³/h) at 2.56 in H₂O (638 Pa)
Reduced-Speed Airflow (1300 RPM Curve) 5875 CFM (9980 m³/h) at 0 Pa; 4890 CFM (8305 m³/h) at 0.75 in H₂O (188 Pa); 3695 CFM (6280 m³/h) at 1.40 in H₂O (349 Pa); 2460 CFM (4175 m³/h) at 1.69 in H₂O (421 Pa)
Reduced-Speed Airflow (1000 RPM Curve) 4520 CFM (7680 m³/h) at 0 Pa; 3760 CFM (6390 m³/h) at 0.45 in H₂O (111 Pa); 2840 CFM (4830 m³/h) at 0.83 in H₂O (206 Pa); 1890 CFM (3215 m³/h) at 1.00 in H₂O (249 Pa)
Max. Static Pressure (Tested Curve Point 4) 3.61 in H₂O (900 Pa) at 3600 CFM (6120 m³/h)
Nominal Static Pressure (Max. Load Point 3) 3.01 in H₂O (750 Pa) at 5415 CFM (9200 m³/h)
Sound Pressure Level (Max. Load Intake) 71 dB(A) at 1 m (Point 3, 1900 RPM)
Free-Air Sound Pressure Level (Intake) 82 dB(A) at 1 m (Point 1, 1900 RPM)
Intermediate Sound Pressure Level (Intake) 76 dB(A) (Point 2 at 400 Pa), 75 dB(A) (Point 4 at 900 Pa)
Sound Power Level (Max. Load Intake) 78 dB(A) (Point 3, 1900 RPM, per ISO 13347)
Free-Air Sound Power Level (Intake) 89 dB(A) (Point 1, 1900 RPM, per ISO 13347)
Sound Power Level (Max. Load Outlet) 85 dB(A) (Point 3, 1900 RPM)
Free-Air Sound Power Level (Outlet) 92 dB(A) (Point 1, 1900 RPM)
Aerodynamic Measurement Standard ISO 5801 Installation Category A (Air Density ρ = 1.15 kg/m³ ± 2%, Measurement ID: 13267)
Ingress Protection (IP) IP55
Moisture / Environmental Class H1
Operating Temperature -40 to +40 °C (-40 to +104 °F) (Occasional startup -40 to -25 °C permitted; continuous operation below -25 °C requires low-temperature bearings)
Storage Temperature -40 to +80 °C (-40 to +176 °F)
Motor & Drive Protection Thermal Overload Protection (Motor & Electronics), Motor Current Limitation, Soft Start, Line Undervoltage / Phase Failure Detection, Reverse Polarity & Locked-Rotor Protection
Electrical Protection Class Class I (with customer connection of protective earth PE)
Touch Current (IEC 60990) <= 3.5 mA (Measuring circuit Fig. 4, TN system)
Insulation Class Class F
Control / Signal Features RS-485 MODBUS-RTU (V6.0), RFID (ISO 15693), Integrated PI Controller, 3 Configurable I/O Ports (0-10 VDC / PWM / 4-20 mA / Digital In / Tach / Diagnostics), Floating Alarm Status Relay, LED Status Display
Auxiliary Voltage Supply / Offline Input (Vout) Parameterizable 3.3 to 24 VDC ±5% Output (Factory Setting: 10 VDC, Pmax = 800 mW, short-circuit-proof SELV); or 15 to 50 VDC External Input for offline MODBUS parameterization
Alarm / Status Relay Contact Rating 250 VAC / 2 A (AC1) / min. 10 mA (Floating NC contact on CON2 COM/NC, breaks on failure)
LED Status Indicator Green (Good / Ready for operation), Orange (Warning), Red (Failure)
Termination Type Integrated Terminal Box (CON1 Mains Power & CON2 SELV Control Interface)
Conduit / Cable Gland Clamping Range Cable Diameter 4 to 10 mm (0.16 to 0.39 in), Gland Tightening Torque 4 ± 0.6 Nm
Terminal Box Cover Tightening Torque 1.5 ± 0.2 Nm
Power Wiring Pinout (CON1) L1, L2, L3 (3-Phase Mains Supply), PE (Protective Earth)
Control & Relay Pinout (CON2) RSA & RSB (RS-485 MODBUS-RTU), GND (Reference Ground), IO1 (Factory: Digital Enable/Disable & Error Reset Input 3.5-50 VDC), IO2 (Factory: 0-10 V / PWM Speed Setpoint Input, Ri = 100 kΩ), IO3 (Factory: 0-10 V Modulation Output, max. 5 mA), Vout (3.3-24 VDC Supply / 15-50 VDC Aux Input), COM & NC (Status Relay)
Impeller Size Ø 500 mm (19.69 in)
Max. Screw Clearance 20 mm (0.79 in)
Blade Count & Geometry 6 Backward-Curved Blades (Single-Intake RadiCal Geometry)
Bearing Type Ball Bearing
Electronics Housing Material Die-Cast Aluminum
Impeller / Blade Material PP Plastic (Polypropylene)
Rotor Surface Painted Black
Direction of Rotation Clockwise (Viewed toward rotor)
Installation Position Shaft Horizontal or Rotor on Bottom (Rotor on top available on request)
Condensation Drainage Holes On Rotor Side
Compatible Inlet Ring (Optional) 50350-2-4013 (Standard Inlet Ring) / 50355-2-4013 (Inlet Ring with Pressure Tap, k-factor: 375)
EMC Standards EN 61000-6-2 (Industrial Immunity), EN 61000-6-3 (Emission, except EN 61000-3-2 for professional equipment > 1 kW)
Standards & Compliance CE, EN 61800-5-1, UL 1004-7, UL 60730-1, CSA C22.2 No. 77, CAN/CSA-E60730-1

Applications

ebm-papst R3G500-8317081581 backward-curved EC centrifugal fans are engineered for high-static-pressure plenum installations in commercial air handling units (AHUs), data center CRAC/CRAH precision cooling systems, and large building heat recovery ventilation (HRV) arrays. Its unhoused single-intake motorized impeller geometry and integrated MODBUS-RTU / PI control interface allow direct integration into modular FanGrid walls, cleanroom recirculation plenums, and industrial process chillers. Maintenance and OEM engineers rely on this unit for mission-critical facility ventilation, wind power converter cabinets, and heavy industrial environmental control systems requiring automated air volume modulation and remote diagnostics.