Description
ebm-papst R3G250-RG70-16 (also known as R3G250RG7016) is a single-intake, unhoused backward-curved EC centrifugal motorized impeller engineered with an integrated M3G074-CF electronically commutated motor and a 250 mm (9.84 in) diameter impeller. Operating on single-phase 115 VAC (100 to 130 VAC range) at 50/60 Hz, this unit delivers a nominal speed of 2500 RPM at 164 W (2.0 A) under maximum load, achieving up to 820 CFM (1395 m³/h) of free-air airflow and static pressure up to 1.85 in H₂O (460 Pa) along its performance curve. Constructed with a red-brown polyamide (PA) plastic impeller and maintenance-free ball bearings, it features electrically isolated 0-10 VDC / PWM speed control, an open-collector tachometer output, soft start, and internally connected thermal overload protection.
Key Features
- High-Efficiency EC Aerodynamics: Delivers 820 CFM (1395 m³/h) maximum airflow and static pressure up to 1.85 in H₂O (460 Pa).
- Integrated M3G074-CF EC Motor: Operates across 100 to 130 VAC (50/60 Hz) with soft start and active motor current limitation.
- Closed-Loop Control Interface: Equipped with electrically isolated 0-10 VDC / PWM control input, 10 VDC supply, and 1 PPR tachometer output.
- Durable Polyamide Impeller: Single-intake backward-curved Ø250 mm impeller molded from red-brown PA plastic with precision ball bearings.
- Comprehensive Thermal & Environmental Protection: Rated IP44 and Moisture Class F3-1 with internal thermal overload protection (TOP) for electronics and motor.
- Industrial EMC & Safety Compliance: Certified to UL 2111, CSA C22.2 No. 77, EN 60335-1, and EN 61000-6-2/6-3 electromagnetic standards.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | R3G250-RG70-16 |
| Alternate Part Number | R3G250RG7016 |
| OEM Item Number | 51511-5-9980 |
| Integrated Motor Model | M3G074-CF |
| Product Category | EC Centrifugal Fans |
| Fan / Component Type | Single-Intake Backward-Curved Motorized Impeller (Unhoused) |
| Motor Design / Technology | Electronically Commutated (EC) External Rotor Motor |
| Phase & Supply Type | 1~ (Single-Phase AC Input) |
| Rated Voltage | 115 VAC |
| Operating Voltage Range | 100 to 130 VAC |
| Frequency | 50 / 60 Hz |
| Speed (RPM) | 2500 RPM (Nominal Max. Load) / 2555 RPM (Free Air) |
| Power Rating | 164 W (Nominal Max. Load) / 139 W (Free Air) |
| Max. Input Power | 170 W (Measured at 360 Pa Duty Point) |
| Rated Current | 2.0 A (Nominal Max. Load) / 1.78 A (Free Air) |
| Max. Current Draw | 2.10 A (Measured at 360 Pa Duty Point) |
| Airflow (Max. Free Air) | 820 CFM (1395 m³/h) at 0 Pa |
| Operating Duty Point Airflow | 690 CFM (1170 m³/h) at 200 Pa / 510 CFM (865 m³/h) at 360 Pa / 325 CFM (555 m³/h) at 460 Pa |
| Static Pressure (Nominal Duty) | 1.45 in H₂O (360 Pa) at 2500 RPM |
| Max. Tested Static Pressure | 1.85 in H₂O (460 Pa) at 325 CFM (555 m³/h) |
| Impeller Size | Ø 250 mm (9.84 in) |
| Impeller / Blade Material | PA Plastic, Red-Brown (Backward-Curved) |
| Compatible Inlet Ring Accessory | Part No. 96359-2-4013 (Not Included in Scope of Delivery) |
| Mounting Thread & Screw Clearance | Self-Tapping M4 Tapping Holes (6 mm & 8 mm Max. Clearance) / Rotor Screw Clearance 8–10 mm (Torque 2.5 ± 2 Nm) |
| Bearing Type | Ball Bearing |
| Direction of Rotation | Clockwise, Viewed Toward Rotor |
| Installation Position | Shaft Horizontal or Rotor on Top (Rotor on Bottom on Request) |
| Condensation Drainage Holes | None |
| Operating Mode / Duty Cycle | S1 (Continuous Duty) |
| Weight | 2.4 kg (5.29 lbs) |
| Termination Type | Dual Multi-Conductor Cables with Crimped Ferrules |
| Lead Wire Gauge & Spec | Power Cable: AWG 18 (3x Crimped Ferrules) / Control Cable: AWG 22 (4x Crimped Ferrules) |
| Power Wiring Pinout | Conn. 4 L (Black: Power Supply), Conn. 3 N (Blue: Neutral), Conn. 1 PE (Green/Yellow: Protective Earth) |
| Control Wiring Pinout | Conn. 8 (Yellow: 0-10 V / PWM Input), Conn. 9 (White: Tach Output), Conn. 11 (Red: +10 V / max. 1.1 mA Output), Conn. 12 (Blue: Control GND) |
| Control / Signal Features | 0-10 VDC / PWM Speed Control (Electrically Isolated), Open-Collector Tachometer Output (1 Pulse/Rev), +10 VDC Auxiliary Output, Soft Start, Motor Current Limitation |
| Motor Protection | Thermal Overload Protector (TOP) Internally Connected for Electronics and Motor |
| Electrical Protection Class | Class I (With Customer Connection of Protective Earth) |
| Touch Current (IEC 60990) | <= 3.5 mA (Measuring Circuit Fig. 4, TN System) |
| Insulation Class | Class B |
| Ingress Protection (IP) | IP44 (Installation- and Position-Dependent) |
| Moisture / Environmental Class | F3-1 |
| Operating Temperature | -25 °C to +50 °C (-13 °F to +122 °F) |
| Storage Temperature | -40 °C to +80 °C (-40 °F to +176 °F) |
| EMC Standards | EN 61000-6-2 (Immunity), EN 61000-3-2/3 (Circuit Feedback), EN 61000-6-3 (Emission) |
| Standards & Compliance | UL 2111, CSA C22.2 No. 77, EN 60335-1 |
Applications
ebm-papst R3G250-RG70-16 unhoused backward-curved EC centrifugal fans are engineered for pressurized plenum installations where high static efficiency and variable speed modulation are required without a bulky scroll housing. Typical OEM and MRO deployments include data center computer room air handlers (CRAH), cleanroom fan filter units (FFUs), commercial heat recovery ventilation (HRV) systems, and ducted air handling plenums. They also provide reliable closed-loop thermal management inside power electronics enclosures, medical imaging cabinets, industrial chillers, and telecommunications infrastructure.





