K3G560-AP32-68 ebm-papst 400VAC 560mm EC Centrifugal Fan

$524.00

ebm-papst K3G560-AP32-68 (K3G560AP3268) 400VAC 560mm EC centrifugal fan, 1610RPM, 9500CFM (16145m³/h), 3530W, with M3G150-IF motor, RS485 MODBUS & IP55.

SKU: K3G560-AP32-68 Category: Brand:

Description

ebm-papst K3G560-AP32-68 (also known as K3G560AP3268) is a heavy-duty 560 mm (22.05 in) single-inlet backward-curved EC centrifugal plug fan module integrated with an M3G150-IF electronically commutated motor, galvanized steel mounting plate, inlet nozzle with pressure tap, and black-coated steel support bracket. Operating across a 3-phase 380 to 480 VAC (400 VAC nominal) 50/60 Hz power supply, this motorized impeller delivers a maximum free-air flow of 9,500 CFM (16,145 m³/h), a peak static pressure of 4.14 in H₂O (1,030 Pa), and a nominal maximum-load rating of 3,530 W and 5.4 A at 1,610 RPM. Engineered for high-reliability industrial ventilation, it features a 7-blade sheet aluminum impeller, die-cast aluminum electronics housing, ball bearings, RS-485 MODBUS RTU and 0–10 VDC/PWM control interfaces, passive PFC, and IP55 environmental protection.

Key Features

  • High-Output EC Aerodynamics: Delivers up to 9,500 CFM (16,145 m³/h) free-air flow and 4.14 in H₂O (1,030 Pa) static pressure at 1,610 RPM.
  • Integrated M3G150-IF EC Motor: Wide-range 3-phase 380–480 VAC 50/60 Hz operation achieving 70.1% overall static efficiency (ErP Grade N 74.9).
  • RS-485 MODBUS & PID Control: Equipped with RS-485 MODBUS RTU, 0–10 VDC/PWM and 4–20 mA inputs, integrated PID controller, and floating status relay.
  • Complete Plug-Fan Module: Combines a 7-blade aluminum backward-curved impeller, galvanized mounting plate, support brackets, and k-factor 348 pressure-tap inlet cone.
  • Comprehensive Electronic Protection: Includes passive PFC, soft start, line undervoltage/phase-failure detection, thermal overload protection, and locked-rotor protection.
  • IP55 Industrial Durability: Built with Class F insulation, F4-1 moisture protection, rotor-side condensate drains, and ball bearings for -25°C to +40°C service.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) K3G560-AP32-68
Alternate Part Number K3G560AP3268
Manufacturer Item Number 54302-5-9980
Integrated Motor Model M3G150-IF
Product Category EC Centrifugal Fans
Fan / Component Type Backward-Curved EC Centrifugal Module with Support Bracket & Inlet Nozzle
Motor Design / Technology External Rotor Electronically Commutated (EC) Motor with Integrated Electronics
Phase & Supply Type 3~ (3-Phase AC Input)
Rated Voltage 400 VAC
Operating Voltage Range 380 to 480 VAC
Frequency 50 / 60 Hz
Speed (RPM) 1610 RPM (Nominal Max. Load) / 1620 RPM (Optimum Efficiency)
Power Rating 3530 W (Max. Load) / 2272 W (Free Air) / 3490 W (ErP Optimum Efficiency)
Rated Current 5.40 A (Max. Load) / 3.49 A (Free Air)
Airflow (Max. Free Air) 9500 CFM (16145 m³/h) at 0 Pa (1610 RPM)
Operating Duty Point Airflow 5290 CFM (8985 m³/h) at 900 Pa (3.61 in H₂O) / 7530 CFM (12795 m³/h) at 550 Pa (2.21 in H₂O)
ErP Optimum Efficiency Duty Point 6277 CFM (10665 m³/h) at 783 Pa (3.14 in H₂O)
Static Pressure 3.61 in H₂O (900 Pa) at Max. Load / 4.14 in H₂O (1030 Pa) at 3525 CFM (5990 m³/h)
Sound Pressure Level (Inlet LpAin) 74 dB(A) at 900 Pa (Max. Load) / 86 dB(A) at Free Air (1 m distance)
Sound Power Level (Inlet LwAin) 81 dB(A) at 900 Pa (Max. Load) / 94 dB(A) at Free Air
ErP Efficiency & Grade Overall Static Efficiency ηes: 70.1% (Efficiency Grade N = 74.9, Category A Static)
Impeller Size Ø 560 mm (22.05 in)
Blade Count & Geometry 7 Backward-Curved Blades, Single Inlet
Inlet Nozzle Feature Galvanized Sheet Steel Inlet Nozzle with Pressure Tap (k-factor: 348)
Electronics Housing Material Die-Cast Aluminum
Impeller / Blade Material Sheet Aluminum
Mounting Plate & Bracket Material Galvanized Sheet Steel Mounting Plate; Black-Coated Steel Support Bracket
Rotor Surface Coated in Black
Bearing Type Ball Bearing
Direction of Rotation Clockwise, Seen on Rotor
Installation Position Shaft Horizontal (Support Struts Vertical) or Rotor on Bottom (Rotor on Top on Request)
Condensation Drainage Holes Rotor-Side
Operating Mode / Duty Cycle S1 (Continuous Operation)
Weight 55.0 kg (121.25 lbs)
Termination Type Via Terminal Box (Cable Diameter: 4 to 10 mm, Gland Torque: 4±0.6 Nm)
Mains & Relay Terminal Pinout KL1: L1 (1), L2 (2), L3 (3), PE; KL2 Status Relay: NO (1), COM (2), NC (3) (250 VAC / Max. 2 A AC1)
Control & Bus Terminal Pinout KL3: RSA (1), RSB (2), GND (3/10), Ain1 U 0-10V (4), +10V (5), Ain1 I 4-20mA (6), Din1-3 (7-9), Ain2 U (11), +20V (12), Ain2 I (13), Aout 0-10V (14)
Control / Signal Features RS-485 MODBUS RTU, Integrated PID Controller, 0-10 VDC / PWM & 4-20 mA Inputs, 10V/20V Sensor Outputs, 0-10V Slave Output, Alarm Relay, Passive PFC, Soft Start
Motor Protection Over-Temperature Protected Electronics/Motor, Line Undervoltage/Phase-Failure Detection, Reverse Polarity & Locked-Rotor Protection
Electrical Protection Class Class I (with Customer Protective Earth Connected)
Touch Current (IEC 60990) <= 3.5 mA
Insulation Class Class F
Ingress Protection (IP) IP55
Moisture / Environmental Class F4-1
Operating Temperature -25°C to +40°C (-13°F to +104°F)
Storage Temperature -40°C to +80°C (-40°F to +176°F)
EMC Compliance Immunity: EN 61000-6-2; Emission: EN 61000-6-3
Standards & Compliance CE, EN 61800-5-1, UL 1004-7 + 60730, CSA C22.2 No. 77, CAN/CSA-E60730-1, EAC, ErP 2015 Compliant

Applications

ebm-papst K3G560-AP32-68 backward-curved EC centrifugal plug fan modules are engineered for high-volume pressurized plenum applications in commercial and industrial air handling units (AHUs), data center CRAC/CRAH precision cooling systems, and large-scale rooftop ventilation equipment. The unit’s integrated support bracket, mounting plate, and pressure-tap inlet cone enable direct installation into modular fan walls, cleanroom air makeup systems, and building heat recovery ventilation (HRV) plenums. Its onboard RS-485 MODBUS interface and PID controller support automated demand-controlled airflow management across factory process exhaust and mission-critical facility cooling retrofits.