K3G450-PB24-01/F01 ebm-papst 400VAC 450mm EC Centrifugal Fan

$700.00

ebm-papst K3G450-PB24-01/F01 (K3G450PB2401F01) 400VAC 450mm RadiPac EC centrifugal fan, 2600RPM, 8860CFM (15055m³/h), 5250W, with MODBUS-RTU, M3G150-IF motor & IP55.

SKU: K3G450-PB24-01/F01 Category: Brand:

Description

ebm-papst K3G450-PB24-01/F01 (also known as K3G450PB2401F01) is a RadiPac series single-intake, backward-curved EC centrifugal fan module with an integrated support bracket and M3G150-IF brushless motor, built around a 450 mm (17.72 in) 5-blade sheet aluminum impeller inside a 630 × 630 × 556 mm (24.80 × 24.80 × 21.89 in) frame. Operating on 3-phase 400 VAC (380–480 VAC, 50/60 Hz) power, it delivers up to 8,860 CFM (15,055 m³/h) of free-air airflow at 2,600 RPM and achieves a nominal maximum-load duty point of 5,325 CFM (9,045 m³/h) at 5.62 in H₂O (1,400 Pa) static pressure (5,250 W, 8.00 A).

Designed for heavy-duty industrial ventilation, this module features a galvanized sheet steel support plate and k-factor 240 pressure-tap inlet ring, a die-cast aluminum terminal box, dual analog/digital control inputs, an onboard PID controller, RS-485 MODBUS-RTU networking, and IP55 / Class F environmental protection.

Key Features

  • High-Static RadiPac Aerodynamics: 450 mm 5-blade backward-curved aluminum impeller delivers 8,860 CFM free air and up to 7.23 in H₂O (1,800 Pa) curve static pressure.
  • Integrated M3G150-IF EC Drive: 3-phase 380–480 VAC electronically commutated motor achieves 2,600 RPM speed with passive PFC, soft start, and active power/current limiting.
  • RS-485 MODBUS-RTU & PID Control: SELV control interface offers MODBUS-RTU bus networking, dual 0–10 V / 4–20 mA sensor inputs, 3 digital inputs, and closed-loop PID.
  • Plug-and-Play Support Bracket Cube: Pre-assembled black-painted steel support struts and galvanized base plate with 580 × 580 mm mounting pitch and FlowGrid mounting holes.
  • K-Factor 240 Piezo Inlet Ring: Galvanized steel intake nozzle incorporates an integrated differential pressure tap (k-factor 240) for direct volumetric airflow monitoring.
  • Industrial IP55 & Fault Protection: H1 moisture resistance, Class F insulation, phase-failure/undervoltage detection, thermal overload protection, and a 250 VAC / 2 A status relay.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) K3G450-PB24-01/F01
Alternate Part Number K3G450PB2401F01
OEM Item Number 8317078213
Integrated Motor Model M3G150-IF (Motor Size 150)
Product Series RadiPac
Product Category EC Centrifugal Fans
Fan / Component Type Backward-Curved Single-Intake EC Centrifugal Module with Support Bracket
Motor Design / Technology Electronically Commutated (EC) External Rotor Motor with Integrated Electronics
Phase & Supply Type 3~ (3-Phase AC Input to Integrated EC Drive)
Rated Voltage 400 VAC
Operating Voltage Range 380 to 480 VAC
Frequency 50 / 60 Hz
Speed (RPM) 2,600 RPM (at Max. Load)
Free-Air Speed (RPM) 2,600 RPM (at 0 Pa Free Air)
Power Rating 5,250 W (at Max. Load, 1,400 Pa)
Free-Air Power Input 3,067 W (at 0 Pa Free Air)
Rated Current 8.00 A (at Max. Load, 1,400 Pa)
Free-Air Current Draw 4.78 A (at 0 Pa Free Air)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 8,860 CFM (15,055 m³/h) at 0 in H₂O (0 Pa)
Operating Duty Point Airflow 7,010 CFM (11,910 m³/h) at 3.21 in H₂O (800 Pa) [4,640 W, 7.13 A]; 5,325 CFM (9,045 m³/h) at 5.62 in H₂O (1,400 Pa) [Nominal Max. Load: 5,250 W, 8.00 A]; 3,720 CFM (6,320 m³/h) at 7.23 in H₂O (1,800 Pa) [5,141 W, 7.89 A]
Max. Static Pressure (Chart Curve) 7.23 in H₂O (1,800 Pa) at 3,720 CFM (6,320 m³/h)
Aerodynamic Measurement Standard ISO 5801 Installation Category A (Measurement LU-10424 at ρ = 1.15 kg/m³ ± 2%)
Airflow Direction Axial Intake, Radial 360° Discharge
Ingress Protection (IP) IP55
Moisture / Environmental Class H1
Operating Temperature -25 °C to +50 °C (-13 °F to +122 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Motor & Drive Protection Thermal Overload Protection (Motor/Electronics), Line Undervoltage & Phase Failure Detection, Locked-Rotor Protection, Reverse Polarity Protection, Motor Current & Power Limiter, Soft Start, Passive PFC
Electrical Protection Class Class I (with Customer Connection of Protective Earth)
Touch Current (IEC 60990) <= 3.5 mA (Measuring Circuit Fig. 4, TN System)
Insulation Class Class F
Control / Signal Features RS-485 MODBUS-RTU, Dual Analog Inputs (0–10 VDC / PWM or 4–20 mA), 3 Digital Inputs (Enable/Reset, Parameter Set 1/2, Controller Direction), Integrated PID Controller, 0–10 V Slave/Modulation Output, +10 VDC (10 mA) & +20 VDC (50 mA) Aux Outputs, External 24 VDC Parameterization Input, Operation/Alarm Display, Floating Changeover Status Relay (SELV Isolated)
Termination Type Internal Terminal Box (Terminal Strips KL1, KL2, KL3)
Conduit / Cable Gland Ports 2 × M20 × 1.5 (Cable Ø 4–10 mm / 0.16–0.39 in, Torque 4 ± 0.6 Nm); 1 × M25 × 1.5 (Cable Ø 9–16 mm / 0.35–0.63 in, Torque 6 ± 0.9 Nm); Terminal Cover Torque 3.5 ± 0.5 Nm
Power Wiring Pinout (KL1) KL1-1 = L1 (Phase 1), KL1-2 = L2 (Phase 2), KL1-3 = L3 (Phase 3), PE = Protective Earth
Status Relay Pinout (KL2) KL2-1 = NO (Make for Failure), KL2-2 = COM (Common, max. 250 VAC / 2 A AC1, min. 10 mA), KL2-3 = NC (Break for Failure)
Control & Bus Pinout (KL3) KL3-1 = RSA (RS-485 MODBUS-RTU), KL3-2 = RSB (RS-485 MODBUS-RTU), KL3-3/10 = GND, KL3-4 = Ain1 U (0–10 V Setpoint, Ri = 100 kΩ), KL3-5 = +10 VDC Out (max. 10 mA), KL3-6 = Ain1 I (4–20 mA Setpoint, Ri = 100 Ω), KL3-7 = Din1 (Enable 5–50 VDC / Open; Disable/Reset < 1 VDC), KL3-8 = Din2 (Parameter Set 1/2), KL3-9 = Din3 (Controller Action Normal/Inverse), KL3-11 = Ain2 U (0–10 V Sensor, Ri = 100 kΩ), KL3-12 = +20 VDC Out (max. 50 mA) / +24 VDC Param Input, KL3-13 = Ain2 I (4–20 mA Sensor, Ri = 100 Ω), KL3-14 = Aout (0–10 V Modulation Out, max. 5 mA)
Impeller Size Ø 450 mm (17.72 in) Nominal / Ø 454 mm (17.87 in) Actual Outer Diameter
Dimensions (L × H × D) 630 × 630 × 556 mm (24.80 × 24.80 × 21.89 in)
Total Axial Depth 556 ± 3 mm (21.89 ± 0.12 in)
Module Cage Axial Depth 442.5 ± 2 mm (17.42 ± 0.08 in)
Inlet Nozzle / Intake Ring Diameter Ø 622 mm (24.49 in) Outer Flange / Ø 440 mm (17.32 in) Intake Throat (with k-factor 240 Pressure Tap & 4 × 90° FlowGrid Mounting Holes)
Mounting Hole Pitch 580 × 580 mm (22.83 × 22.83 in) Square Bolt Pattern
Mounting Hole Diameter / Thread Size Ø 9 mm (0.35 in) (4× Corner Mounting Holes)
Weight 49 kg (108.03 lbs)
Blade Count & Geometry 5 Backward-Curved 3D Blades
Bearing Type Ball Bearing
Electronics Housing Material Die-Cast Aluminum
Housing / Scroll / Frame Material Galvanized Sheet Steel Support Plate & Inlet Nozzle; Black-Painted Steel Support Bracket
Impeller / Blade Material Sheet Aluminum
Rotor Surface Painted Black
Direction of Rotation Clockwise (Viewed Toward Rotor)
Installation Position Shaft Horizontal (Support Struts Installed Vertically Only) or Rotor on Bottom (Rotor on Top on Request)
Condensation Drainage Holes On Rotor Side
EMC Standards EN 61000-6-2 (Industrial Immunity), EN 61000-6-3 (Emission, except EN 61000-3-2 for > 1 kW Professional Equipment)
Standards & Compliance CE, EN 61800-5-1, UL 1004-7 + 60730-1, CSA C22.2 No. 77 + CAN/CSA-E60730-1, EAC

Applications

The ebm-papst K3G450-PB24-01/F01 RadiPac EC centrifugal fan module is engineered for high-pressure plenum pressurization in commercial and industrial HVAC air handling units (AHUs), data center CRAC and CRAH precision cooling systems, and modular FanGrid array walls. Its integrated support bracket, piezo pressure-tap inlet nozzle, and onboard closed-loop PID controller enable direct installation inside hospital cleanroom makeup air systems, pharmaceutical air filtration plenums, and semiconductor fab ventilation ducts. It is also widely deployed for heavy-duty heat recovery ventilation (HRV) units, industrial process drying chambers, and large power electronics or wind turbine converter cooling enclosures.