Description
ebm-papst G1G170-AB31-51 (also known as G1G170AB3151) is an OEM-grade single-inlet backward-curved EC centrifugal gas blower (Item No. 50129-5-9980) with a flanged die-cast aluminum scroll housing, an integrated M1G074-CF electronically commutated motor, and a 170 mm (6.69 in) aluminum sheet impeller engineered for gas-condensing heating appliances. Operating on single-phase 230 VAC (50/60 Hz) power, it delivers 6530 RPM at maximum load (410 W, 1.80 A) to generate 223.66 CFM (380 m³/h) at 8.03 in H₂O (2000 Pa) minimum back pressure, while accelerating up to 7250 RPM (326 W, 1.44 A) at high-pressure duty points of 12.85 in H₂O (3200 Pa) and 88.29 CFM (150 m³/h).
Built for demanding combustion air and gas-premix environments handling flow medium temperatures up to +80 °C (+176 °F), the housing side parts are sealed with a pentane-resistant NBR round cord and include a bleeder connection port for pressure relief. The blower integrates ball bearings, active power factor correction (PFC), motor current limiting, internal thermal overload protection (TOP), a 2–6 kHz PWM speed control input, and a 3-pulse-per-revolution tachometer output terminated via dedicated 3-pole power (ST1) and 5-pole control (ST2) plug connectors.
Key Features
- High-Pressure EC Aerodynamics: Delivers 223.66 CFM (380 m³/h) at 2000 Pa and scales to 7250 RPM at 3200 Pa static pressure.
- Sealed Gas-Tight Construction: Die-cast aluminum flanged housing with pentane-resistant NBR round cord seal, aluminum impeller, and pressure-relief bleeder port.
- Active PFC & Motor Protection: Integrated M1G074-CF EC motor features active PFC, current limiting, over-temperature protection, and internal TOP.
- PWM Speed Control & Tachometer: Supports 2–6 kHz PWM speed modulation, 3 pulses/rev speed monitoring output (DUE), and 24–45 VDC interface.
- High-Temperature Medium Rating: Engineered for gas-condensing systems with flow medium tolerance from -25 °C to +80 °C (-13 °F to +176 °F).
- Industrial EMC & Safety Compliance: Certified to UL 507, CSA C22.2 No. 113, and CE with EN 61000-6-2/6-4 industrial EMC immunity and emissions.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | G1G170-AB31-51 |
| Alternate Part Number | G1G170AB3151 |
| OEM Item Number | 50129-5-9980 (Revision 66688) |
| Integrated Motor Model | M1G074-CF |
| Product Series | G1G170 Series |
| Product Category | EC Blower Fans |
| Fan / Component Type | Single-Inlet Backward-Curved EC Centrifugal Gas Blower with Flanged Housing |
| Motor Design / Technology | Electronically Commutated (EC) External Rotor Motor with Active PFC |
| Phase & Supply Type | 1~ (Single-Phase AC Input) |
| Rated Voltage | 230 VAC |
| Frequency | 50 / 60 Hz |
| Speed (Max. Load) | 6530 RPM (Duty Point 1 at 2000 Pa) |
| High-Pressure Operating Speed | 6665 RPM (at 2400 Pa); 6915 RPM (at 2800 Pa); 7250 RPM (at 3200 Pa) |
| Power Rating (Max. Load) | 410 W (Duty Point 1 at 2000 Pa) |
| High-Pressure Power Input | 400 W (at 2400 Pa); 370 W (at 2800 Pa); 326 W (at 3200 Pa) |
| Rated Current (Max. Load) | 1.80 A (Duty Point 1 at 2000 Pa) |
| High-Pressure Current Draw | 1.75 A (at 2400 Pa); 1.62 A (at 2800 Pa); 1.44 A (at 3200 Pa) |
| Power Factor Correction (PFC) | Active PFC |
| Operating Duty Point 1 (Max. Load) | 223.66 CFM (380 m³/h) at 8.03 in H₂O (2000 Pa) — 6530 RPM, 410 W, 1.80 A |
| Operating Duty Point 2 | 194.23 CFM (330 m³/h) at 9.63 in H₂O (2400 Pa) — 6665 RPM, 400 W, 1.75 A |
| Operating Duty Point 3 | 147.15 CFM (250 m³/h) at 11.24 in H₂O (2800 Pa) — 6915 RPM, 370 W, 1.62 A |
| Operating Duty Point 4 | 88.29 CFM (150 m³/h) at 12.85 in H₂O (3200 Pa) — 7250 RPM, 326 W, 1.44 A |
| Min. Back Pressure | 8.03 in H₂O (2000 Pa) |
| Max. Static Pressure (Chart Curve) | 13.86 in H₂O (3450 Pa) at Shut-Off (12.85 in H₂O / 3200 Pa at Duty Point 4) |
| Air Performance Test Standard | ISO 5801 Installation Category A (Measurement LU-56469 at 1.2 kg/m³) |
| Ingress Protection (IP) | IP20 |
| Operating Ambient Temperature | -25 °C to +55 °C (-13 °F to +131 °F) |
| Flow Medium Temperature Range | -25 °C to +80 °C (-13 °F to +176 °F) |
| Storage & Transport Temperature | -40 °C to +80 °C (-40 °F to +176 °F) |
| Motor & Drive Protection | Internal Thermal Overload Protector (TOP), Over-Temperature Protected Motor, Motor Current Limit, Active PFC |
| Touch / Leakage Current | <= 3.5 mA |
| Insulation Class | Class “B” |
| Control / Signal Features | PWM Control Input (2–6 kHz; PWM On n = 100%, PWM Low n = 0%), Tachometer Speed Output (3 pulses/rev, 1 mA current source), External Control Supply (24–45 VDC) |
| Termination Type | Electrical Leads with Dual Plug Connectors (ST1 3-Pole Power Strip & ST2 5-Pole Control Strip) |
| Mating Power Connector (ST1) | 3-Pole Strip — Mating Housing: Tyco No. 350 766-1; Female Terminal: Tyco No. 926 884-1 (Not Included) |
| Mating Control Connector (ST2) | 5-Pole Strip — Mating Housing: Molex No. 39-01-4050; Female Terminal: Molex No. 39-00-0059 (Not Included) |
| Power Wiring Pinout (ST1) | Pin 1 (2.1): L (Line 230 VAC, 50/60 Hz); Pin 2 (2.2): N (Neutral Conductor); Pin 3 (2.3): PE (Protective Earth) |
| Control & Signal Pinout (ST2) | Pin 1 (3.1): UB (+ External Voltage 24–45 VDC); Pin 2 (3.2): DUE (Speed Monitoring Output, 3 pulses/rev, 1 mA); Pin 3 (3.3): N.C. (Not Assigned); Pin 4 (3.4): PWM (2–6 kHz Control Input); Pin 5 (3.5): GND (- Control Interface Ground) |
| Impeller Size | Ø 170 mm (6.69 in) |
| Weight | 4.7 kg (10.36 lbs) |
| Bearing Type | Ball Bearing |
| Housing / Scroll Material | Die-Cast Aluminum with Flanged Outlet |
| Housing Seal & Pressure Relief | Housing Side Parts Sealed with Pentane-Resistant NBR Round Cord; Integrated Bleeder Connection Port for Pressure Relief |
| Impeller / Blade Material | Aluminum Sheet (Backward-Curved) |
| Protective Cover Material | Polyflam RPP 374-ND CS1 (UL 94V-0 / UL 97-V0 Flame Retardant) |
| Rotor Surface | Coated in Black |
| Cooling Bore / Aperture | Rotor-Side |
| Direction of Rotation | Clockwise, Seen on Rotor |
| Installation Position | Any |
| EMC Standards | EN 61000-6-2 (Interference Immunity), EN 61000-6-4 (Industrial Interference Emission), EN 61000-3-2/3 (Harmonics) |
| Standards & Compliance | CE, UL 507, CSA C22.2 No. 113 |
Applications
The ebm-papst G1G170-AB31-51 flanged backward-curved EC gas blower is purpose-built for gas-condensing boilers, commercial hydronic heating units, premix gas burner assemblies, and industrial process heating equipment requiring precise air-fuel ratio modulation against high combustion chamber back pressure. Its pentane-resistant NBR housing seal, pressure-relief bleeder connection, and high-temperature flow medium capability ensure dependable operation in sealed combustion circuits, condensing heat exchangers, and industrial drying furnaces. Integrated PWM speed control and pulse-per-revolution tachometer feedback allow seamless closed-loop integration with automated burner management controllers in both OEM thermal appliances and MRO field replacements.