D2E146-AP47-02 ebm-papst 230VAC 146mm AC Centrifugal Blower

$786.00

ebm-papst D2E146-AP47-02 (D2E146AP4702) 230VAC Ø146mm dual-inlet blower, 2050/2550RPM, 570CFM (970m³/h), 300/330W, with galvanized steel scroll & M2E068-EC motor.

SKU: D2E146-AP47-02 Category: Brand:

Description

ebm-papst D2E146-AP47-02 (also known as D2E146AP4702, OEM Item No. 10542-5-9980) is a dual-intake, forward-curved AC centrifugal scroll blower with a flangeless galvanized sheet-steel housing, powered by an integrated M2E068-EC external rotor motor and an Ø146 mm (5.75 in) impeller. Operating on single-phase 230 VAC (50 / 60 Hz) with an 8 µF / 400 VDB run capacitor, this continuous-duty (S1) blower achieves a nominal maximum-load speed of 2050 RPM (50 Hz) / 2550 RPM (60 Hz) at 300 W / 330 W (1.31 A / 1.45 A). It delivers 570 CFM (970 m³/h) at 0.80 in H₂O (200 Pa) on 50 Hz and 410 CFM (700 m³/h) at 1.61 in H₂O (400 Pa) on 60 Hz, reaching static pressures up to 1.77 in H₂O (440 Pa) at 50 Hz and 2.51 in H₂O (625 Pa) at 60 Hz along its measured duty curve.

Engineered for industrial durability, it incorporates precision ball bearings, one-sided bracket motor suspension, an internally connected thermal overload protector (TOP), IP44 protection, and an axial 4G 0.5 mm² PVC lead cable with 4x crimped splices.

Key Features

  • Dual-Inlet Aerodynamic Output: Delivers 570 CFM (970 m³/h) at 200 Pa (50 Hz) and 410 CFM (700 m³/h) at 400 Pa (60 Hz).
  • High Static Pressure Capability: Maintains stable airflow against back pressures from 0.80 in H₂O (200 Pa) up to 2.51 in H₂O (625 Pa).
  • Galvanized Steel Scroll Construction: Features a corrosion-resistant galvanized sheet-steel scroll housing (without flange) paired with an Ø146 mm forward-curved dual-intake impeller.
  • M2E068-EC External Rotor Drive: Powered by a single-phase 230 VAC motor with ball bearings, one-sided bracket suspension, and 8 µF / 400 VDB capacitor.
  • Integrated Thermal Overload Protection: Built-in internally connected TOP sensor, Class B insulation, IP44 environmental sealing, and Class I protective earth safety.
  • Pre-Terminated Axial Cable Harness: Equipped with an axial-exit 4G 0.5 mm² PVC power cable featuring 4x factory-crimped splices for rapid cabinet wiring.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) D2E146-AP47-02
Alternate Part Number D2E146AP4702
OEM Item Number 10542-5-9980 (Change 89188)
Integrated Motor Model M2E068-EC
Product Series D2E146 Series
Product Category AC Blower Fans
Fan / Component Type Dual-Inlet Forward-Curved AC Centrifugal Scroll Blower (With Housing, Without Flange)
Motor Design / Technology AC External Rotor Capacitor-Run Induction Motor
Phase & Supply Type 1~ (Single-Phase AC)
Rated Voltage 230 VAC
Frequency 50 / 60 Hz
Speed (Max. Load) 2050 RPM (50 Hz) / 2550 RPM (60 Hz)
Speed (Curve Point 2) 2265 RPM (50 Hz at 300 Pa) / 2770 RPM (60 Hz at 475 Pa)
Speed (Curve Point 3) 2490 RPM (50 Hz at 380 Pa) / 2975 RPM (60 Hz at 550 Pa)
Speed (Curve Point 4) 2675 RPM (50 Hz at 440 Pa) / 3095 RPM (60 Hz at 625 Pa)
Power Rating (Max. Load) 300 W (50 Hz) / 330 W (60 Hz)
Power Input (Curve Point 2) 267 W (50 Hz at 300 Pa) / 300 W (60 Hz at 475 Pa)
Power Input (Curve Point 3) 232 W (50 Hz at 380 Pa) / 277 W (60 Hz at 550 Pa)
Power Input (Curve Point 4) 191 W (50 Hz at 440 Pa) / 260 W (60 Hz at 625 Pa)
Rated Current (Max. Load) 1.31 A (50 Hz) / 1.45 A (60 Hz)
Current Draw (Curve Point 2) 1.18 A (50 Hz at 300 Pa) / 1.36 A (60 Hz at 475 Pa)
Current Draw (Curve Point 3) 1.02 A (50 Hz at 380 Pa) / 1.28 A (60 Hz at 550 Pa)
Current Draw (Curve Point 4) 0.84 A (50 Hz at 440 Pa) / 1.22 A (60 Hz at 625 Pa)
Inrush / Starting Current 1.53 A (50 Hz) / 1.56 A (60 Hz)
Run Capacitor 8 µF, 400 VDB (Standard S0 per CE)
Capacitor Wiring / Operation Mode Y (Single-Phase Capacitor-Run)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Load Duty Point 1) 570 CFM (970 m³/h) at 0.80 in H₂O (200 Pa) [50 Hz] / 410 CFM (700 m³/h) at 1.61 in H₂O (400 Pa) [60 Hz]
Operating Duty Point 2 Airflow 490 CFM (830 m³/h) at 1.20 in H₂O (300 Pa) [50 Hz] / 325 CFM (550 m³/h) at 1.91 in H₂O (475 Pa) [60 Hz]
Operating Duty Point 3 Airflow 375 CFM (635 m³/h) at 1.53 in H₂O (380 Pa) [50 Hz] / 230 CFM (390 m³/h) at 2.21 in H₂O (550 Pa) [60 Hz]
Operating Duty Point 4 Airflow 215 CFM (365 m³/h) at 1.77 in H₂O (440 Pa) [50 Hz] / 125 CFM (210 m³/h) at 2.51 in H₂O (625 Pa) [60 Hz]
Min. Back Pressure 0.80 in H₂O (200 Pa) [50 Hz] / 1.61 in H₂O (400 Pa) [60 Hz]
Max. Measured Curve Static Pressure 1.77 in H₂O (440 Pa) [50 Hz] / 2.51 in H₂O (625 Pa) [60 Hz]
Max. Shut-Off Static Pressure (Chart Curve) Approx. 1.93 in H₂O (480 Pa) [50 Hz] / Approx. 2.69 in H₂O (670 Pa) [60 Hz]
Aerodynamic Measurement Setup ISO 5801 Installation Category A (Test LU-32744-1 at 50 Hz / LU-32745-1 at 60 Hz)
Ingress Protection (IP) IP44 (Installation- and Position-Dependent)
Moisture / Environmental Class H0 (Dry Environment)
Operating Temperature -25 °C to +30 °C (-13 °F to +86 °F) [50 Hz] / -25 °C to +25 °C (-13 °F to +77 °F) [60 Hz]
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Motor & Drive Protection Thermal Overload Protector (TOP) Internally Connected
Electrical Protection Class Class I (With Customer Connection of Protective Earth)
Touch Current (IEC 60990) < 0.75 mA (Measuring Circuit Fig. 4, TN System)
Insulation Class Class B
Termination Type 4-Core PVC Cable with 4x Crimped Splices
Cable Exit Orientation Axial Cable Exit
Lead Wire Gauge & Spec PVC 4G 0.5 mm² (Approx. 20 AWG)
Wiring Pinout / Connection U1 = Blue, Z = Brown, U2 = Black, PE = Green/Yellow
Impeller Size Ø146 mm (5.75 in)
Scroll Housing Depth / Width Callouts 205 mm (8.07 in) × 232 mm (9.13 in)
Mounting Hole Diameter Ø5 mm (0.20 in) [4x Mounting Holes]
Weight 4.2 kg (9.26 lbs)
Blade Geometry Forward-Curved Dual-Intake Centrifugal Impeller
Bearing Type Ball Bearing
Motor Suspension Motor Mounted with Brackets on One Side
Housing / Scroll Material Sheet Steel, Galvanized (Without Discharge Flange)
Impeller / Blade Material Sheet Steel, Galvanized
Rotor Surface Unpainted
Direction of Rotation Counterclockwise (Viewed Toward Rotor)
Installation Position Any
Condensation Drainage Holes None
Standards & Compliance CE, EN 60335-1, ISO 5801, ISO 13347, CCC, EAC

Applications

ebm-papst D2E146-AP47-02 dual-inlet forward-curved centrifugal scroll blowers are engineered for ducted and pressurized airflow systems where significant static resistance must be overcome within compact equipment envelopes. Typical deployments include commercial HVAC air handling units (AHUs), variable air volume (VAV) terminal boxes, doorway air curtains, heat recovery ventilation plenums, and laboratory fume extraction hoods. In industrial processing and automation environments, this galvanized steel scroll blower provides reliable forced-convection air circulation for curing and drying ovens, reflow soldering tunnels, packaging and printing machinery, and high-density power electronics cabinets.