D2D160-CE02-11 ebm-papst 230/400VAC 160mm AC Blower Fan

$873.00

ebm-papst D2D160-CE02-11 (D2D160CE0211) 230/400VAC Ø160mm 3-phase dual-inlet blower, 2700/2960RPM, 977/1077CFM, 700/1055W, with steel scroll & M2D074-LA motor.

SKU: D2D160-CE02-11 Category: Brand:

Description

ebm-papst D2D160-CE02-11 (also known as D2D160CE0211) is a heavy-duty 3-phase AC dual-inlet forward-curved centrifugal scroll blower driven by an integrated M2D074-LA external rotor motor with a 160 mm (6.30 in) impeller and pre-mounted angle brackets. Configured for dual-voltage 230 VAC Delta (Δ) or 400 VAC Star (Y) 50/60 Hz operation, it delivers 977.0 CFM (1660 m³/h) at 460 Pa (1.849 in H₂O) on 50 Hz (2700 RPM, 700 W) and 1077.1 CFM (1830 m³/h) at 560 Pa (2.250 in H₂O) on 60 Hz (2960 RPM, 1055 W).

Engineered for high-back-pressure ducted systems, the unit features a galvanized sheet steel scroll housing and impeller, a grey plastic-coated steel guard grille (RAL 9006), dual-sided anti-vibration motor suspension, and maintenance-free ball bearings. Electrical termination is streamlined via an axial-exit 9-pole Weidmüller plug strip (1612160000) with external thermal overload protector (TOP) leads for integration into control circuits.

Key Features

  • Dual-Voltage 3-Phase Operation: Supports 230 VAC Delta (Δ) and 400 VAC Star (Y) 3-phase supply across 50 Hz and 60 Hz networks.
  • High-Pressure Dual-Inlet Aerodynamics: Delivers up to 977.0 CFM (1660 m³/h) at 460 Pa (50 Hz) and 1077.1 CFM (1830 m³/h) at 560 Pa (60 Hz).
  • Galvanized Steel Scroll & Guard: Constructed with a galvanized sheet steel scroll housing, forward-curved impeller, and RAL 9006 plastic-coated steel guard grille.
  • Anti-Vibration Motor Suspension: Integrated M2D074-LA ball-bearing motor is suspended on both sides with anti-vibration mounts for low-resonance S1 continuous duty.
  • Wide Thermal Operating Envelope: Rated for ambient air temperatures from -25 °C to +90 °C (-13 °F to +194 °F) at 50 Hz operation.
  • Pre-Wired Weidmüller Plug & TOP: Equipped with a 9-pole Weidmüller 1612160000 connector strip and brought-out thermal overload protector (TOP) leads.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) D2D160-CE02-11
Alternate Part Number D2D160CE0211
OEM Item Number 13978-5-9980 (Revision 82616 / LU-154175)
Integrated Motor Model M2D074-LA
Product Series D2D160 Series
Product Category AC Blower Fans
Fan / Component Type Dual-Inlet Forward-Curved Centrifugal Scroll Blower with Housing & Angle Bracket
Motor Design / Technology 3-Phase AC External Rotor Induction Motor
Phase & Supply Type 3-Phase (3~) Dual-Voltage Delta (Δ) / Star (Y)
Rated Voltage 230 VAC (Delta Δ) / 400 VAC (Star Y)
Frequency 50 / 60 Hz
Speed (Max. Load) 2700 RPM (50 Hz) / 2960 RPM (60 Hz)
ErP Optimum Speed (RPM) 2795 RPM (50 Hz at Optimum Efficiency)
Speed (Curve Operating Range) 2700 to 2840 RPM (50 Hz, Pts 1–4) / 2960 to 3300 RPM (60 Hz, Pts 1–4)
Power Rating (Max. Load) 700 W (50 Hz) / 1055 W (60 Hz)
ErP Optimum Efficiency Power 520 W / 0.52 kW (50 Hz at Optimum Efficiency)
Power Input (50 Hz Curve Points) 700 W (Pt 1) / 562 W (Pt 2) / 482 W (Pt 3) / 428 W (Pt 4)
Power Input (60 Hz Curve Points) 1055 W (Pt 1) / 871 W (Pt 2) / 737 W (Pt 3) / 592 W (Pt 4)
Rated Current (230 VAC Delta Δ, Max. Load) 1.90 A (50 Hz) / 2.82 A (60 Hz)
Rated Current (400 VAC Star Y, Max. Load) 1.10 A (50 Hz) / 1.63 A (60 Hz)
Current Draw (400 VAC 50 Hz Curve Points) 1.10 A (Pt 1) / 0.97 A (Pt 2) / 0.87 A (Pt 3) / 0.81 A (Pt 4)
Current Draw (400 VAC 60 Hz Curve Points) 1.63 A (Pt 1) / 1.35 A (Pt 2) / 1.16 A (Pt 3) / 0.95 A (Pt 4)
Inrush / Starting Current (230 VAC Delta Δ) 9.25 A (50 Hz) / 9.60 A (60 Hz)
Inrush / Starting Current (400 VAC Star Y) 5.34 A (50 Hz) / 5.54 A (60 Hz)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Max. Airflow (at Min. Back Pressure, Pt 1) 977.0 CFM / 1660 m³/h at 1.849 in H₂O / 460 Pa (50 Hz) / 1077.1 CFM / 1830 m³/h at 2.250 in H₂O / 560 Pa (60 Hz)
Operating Duty Point Airflow (50 Hz Curve) Pt 2: 776.9 CFM (1320 m³/h) at 2.210 in H₂O (550 Pa) | Pt 3: 615.1 CFM (1045 m³/h) at 2.411 in H₂O (600 Pa) | Pt 4: 450.3 CFM (765 m³/h) at 2.733 in H₂O (680 Pa)
Operating Duty Point Airflow (60 Hz Curve) Pt 2: 862.3 CFM (1465 m³/h) at 2.813 in H₂O (700 Pa) | Pt 3: 673.9 CFM (1145 m³/h) at 3.215 in H₂O (800 Pa) | Pt 4: 417.9 CFM (710 m³/h) at 3.818 in H₂O (950 Pa)
ErP Optimum Efficiency Duty Point 709.2 CFM (1205 m³/h) at 2.214 in H₂O (551 Pa)
Min. Back Pressure 1.849 in H₂O / 460 Pa (50 Hz) / 2.250 in H₂O / 560 Pa (60 Hz)
Max. Measured Static Pressure (Pt 4) 2.733 in H₂O / 680 Pa (50 Hz) / 3.818 in H₂O / 950 Pa (60 Hz)
ErP Efficiency & Grade (EU 327/2011) Overall Static Efficiency ηes = 35.9% (Request 2013: 28.9% / Request 2015: 35.9%), Efficiency Grade N = 44 (Request 2013: 37 / Request 2015: 44), Installation Category A, Static, VSD: No, Specific Ratio: 1.01
Ingress Protection (IP) IP00
Moisture / Environmental Class F1-2
Operating Temperature (50 Hz) -25 °C to +90 °C (-13 °F to +194 °F)
Operating Temperature (60 Hz) -25 °C to +50 °C (-13 °F to +122 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Motor & Drive Protection Thermal Overload Protector (TOP) brought out to external connector pins
Electrical Protection Class Class I (with customer protective earth connection)
Touch Current (IEC 60990) < 0.75 mA (Measuring network Fig. 4, TN system)
Insulation Class Class F
Termination Type Electrical leads with 9-pole Weidmüller plug strip (Part No. 1612160000)
Cable Exit Orientation Axial
Wiring Pinout / Connection Pin 1.1: Black (U1/L1) | Pin 1.2: Blue (V1/L2) | Pin 1.3: Brown (W1/L3) | Pin 1.4: Grey (TOP) | Pin 1.5: Green/Yellow (FE Protective Earth) | Pin 1.6: Grey (TOP) | Pin 1.7: Green (U2) | Pin 1.8: White (V2) | Pin 1.9: Yellow (W2)
Delta (Δ) & Star (Y) Winding Configuration Delta (Δ 230 VAC): L1(U1-W2), L2(V1-U2), L3(W1-V2) | Star (Y 400 VAC): L1(U1), L2(V1), L3(W1), Bridge(U2-V2-W2)
Impeller Size Ø 160 mm (6.30 in)
Housing Height & Scroll Depth 332 mm × 283 mm (13.07 in × 11.14 in)
Overall Width (Over Angle Brackets) 318 mm (12.52 in)
Bracket Mounting Pitch 286 mm (11.26 in)
Housing Section Width 250.4 mm (9.86 in)
Discharge Flange Height 127 mm (5.00 in)
Weight 11.1 kg (24.47 lbs)
Bearing Type Ball Bearing
Motor Suspension Motor mounted with anti-vibration isolation on both sides
Housing / Scroll / Frame Material Galvanized sheet steel with mounting angle brackets
Impeller / Blade Material Galvanized sheet steel, forward-curved blades
Guard Grille Material Steel, coated in grey plastic (RAL 9006)
Rotor Surface Coated in black (open rotor design)
Direction of Rotation Counter-Clockwise (CCW) viewed toward rotor (reverses when two phases are swapped)
Installation Position Any
Condensation Drainage Holes None (open rotor)
Standards & Compliance EN 60335-1, CE, UL 1004-1, CSA C22.2 No. 100, CCC

Applications

ebm-papst D2D160-CE02-11 is engineered for high-static-pressure ducted ventilation, process air handling, and industrial thermal management systems requiring continuous dual-inlet centrifugal airflow. It is widely deployed in commercial HVAC air handling units (AHUs), industrial curing and drying ovens, reflow soldering tunnels, packaging and printing machinery, and doorway air curtains. Its galvanized steel scroll housing, pre-fitted angle brackets, and anti-vibration motor suspension make it a direct drop-in OEM component or MRO replacement for high-temperature industrial process enclosures and pressurized cabinet cooling plenums.