Description
ebm-papst A2D250-AD26-05 (also known as A2D250AD2605) is a heavy-duty S-series three-phase AC axial fan engineered around the M2D068-DC external rotor motor with a 250 mm (9.84 in) impeller diameter and 83.00 mm (3.27 in) axial depth. Operating on 400 VAC (50 Hz) / 480 VAC (60 Hz) star (Y) three-phase power, it delivers a nominal speed of 2520 RPM (50 Hz) / 2920 RPM (60 Hz) at 150 W / 230 W and 0.26 A / 0.32 A, while achieving a maximum free-air flow of 745 CFM (1265 m³/h) at 50 Hz and 850 CFM (1450 m³/h) at 60 Hz.
Designed for demanding industrial thermal environments, the fan features 5 black-painted sheet steel sickle-shaped blades with “V” airflow direction and reversible rotation by swapping two supply phases. It is equipped with precision ball bearings for S1 continuous duty, IP44 ingress protection, Class F insulation, H1+/F2-2 environmental rating, rotor-side condensation drainage holes, and a lateral PFA AWG20 4-wire harness terminated with crimped splices.
Key Features
- Three-Phase Star (Y) Performance: Operates on 400 VAC (50 Hz) / 480 VAC (60 Hz) power, delivering up to 850 CFM (1450 m³/h) free-air flow.
- Reversible Rotational Direction: Standard counterclockwise rotation (viewed toward rotor) easily reverses to clockwise by swapping L1 and L2 phases.
- Aerodynamic S-Series Impeller: Five black-painted sheet steel sickle-shaped blades optimize static pressure build-up and acoustic efficiency in “V” airflow.
- Industrial Environmental Durability: IP44 degree of protection, H1+/F2-2 moisture and environmental class, Class F insulation, and rotor-side drainage holes.
- High-Temp PFA Lead Harness: Lateral exit 20 AWG PFA-insulated 4-conductor cable pre-fitted with crimped splice terminals and protective earth.
- Global Regulatory Compliance: Certified to UL 1004-1, CSA C22.2 No. 100, CCC, EAC, CE, EN 60335-1, and RoHS3 standards.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | A2D250-AD26-05 |
| Alternate Part Number | A2D250AD2605 |
| OEM Item Number | 12363-5-9980 |
| Integrated Motor Model | M2D068-DC (Motor Size 68) |
| Product Series | A2D250 (S Series Sickle-Shaped Blades) |
| Product Category | AC Axial Fans |
| Fan / Component Type | Three-Phase AC Axial Fan (Unshrouded Impeller) |
| Motor Design / Technology | 3-Phase AC External Rotor Induction Motor |
| Phase & Supply Type | 3~ (Three-Phase Star / Y Connection) |
| Rated Voltage | 400 VAC (50 Hz) / 480 VAC (60 Hz) |
| Curve Test Voltage | 400 VAC (50 Hz) / 460 VAC (60 Hz) |
| Frequency | 50 / 60 Hz |
| Speed (RPM) | 2520 RPM (50 Hz) / 2920 RPM (60 Hz) (Customer Spec Nominal) |
| Free-Air Speed (RPM) | 2585 RPM (at 400 VAC, 50 Hz) / 2955 RPM (at 460 VAC, 60 Hz) |
| Power Rating | 150 W (50 Hz) / 230 W (60 Hz) (Customer Spec Nominal) |
| Free-Air Power Input | 137 W (at 400 VAC, 50 Hz) / 215 W (at 460 VAC, 60 Hz) |
| Rated Current | 0.26 A (50 Hz) / 0.32 A (60 Hz) (Customer Spec Nominal) |
| Free-Air Current Draw | 0.25 A (at 400 VAC, 50 Hz) / 0.33 A (at 460 VAC, 60 Hz) |
| Operating Mode / Duty Cycle | S1 (Continuous Duty) |
| Airflow (Max. Free Air) | 745 CFM (1265 m³/h) at 50 Hz / 850 CFM (1450 m³/h) at 60 Hz (at 0 Pa / 0.00 in H₂O) |
| Max. Static Pressure | 0.743 in H₂O (185.0 Pa) |
| Aerodynamic Measurement Standard | ISO 5801 Installation Category A (Measurements LU-30683-1 & LU-30685-1) |
| Acoustic Measurement Standard | ISO 13347 (Sound Power) / 1 m Distance from Fan Axis (Sound Pressure) |
| Airflow Direction | “V” (Intake Over Rotor / Exhaust Over Struts) |
| Ingress Protection (IP) | IP44 (Installation- and Position-Dependent per EN 60034-5) |
| Moisture / Environmental Class | H1+ / F2-2 |
| Min. Ambient Operating Temperature | -25 °C (-13 °F) |
| Storage / Transport Temperature | -40 °C to +80 °C (-40 °F to +176 °F) |
| Motor & Drive Protection | No Factory-Installed Overheating Protection (External Motor Protection Required per EN 60335-1) |
| Electrical Protection Class | Class I (With Customer Connection of Protective Earth) |
| Touch Current (IEC 60990) | < 0.75 mA (Measuring Circuit Fig. 4, TN System) |
| Insulation Class | Class “F” |
| Termination Type | 4 Wire Leads with Crimped Splice Terminals |
| Cable Exit Orientation | Lateral |
| Lead Wire Gauge & Spec | PFA Insulated, 20 AWG, 4x Crimped Splices |
| Wiring Pinout (Counterclockwise) | 3~ Star (Y): L1 = V1 (Blue), L2 = U1 (Black), L3 = W1 (Brown), PE = Green/Yellow |
| Wiring Pinout (Clockwise Reversed) | 3~ Star (Y): L1 = U1 (Black), L2 = V1 (Blue), L3 = W1 (Brown), PE = Green/Yellow |
| Impeller Size | Ø 250 mm (9.84 in) |
| Outer Dimensions (Ø × D) | Ø 250 × 83.00 mm (Ø 9.84 × 3.27 in) |
| Total Axial Depth | 83.00 mm (3.27 in) |
| Max. Screw Clearance | 5 mm (0.20 in) |
| Weight | 2.14 kg (4.72 lbs) |
| Blade Count & Geometry | 5 Sickle-Shaped Blades (S Series) |
| Bearing Type | Ball Bearing |
| Impeller / Blade Material | Sheet Steel, Painted Black |
| Rotor Surface | Painted Black |
| Direction of Rotation | Counterclockwise, Viewed Toward Rotor (Reversible by Swapping Two Phases) |
| Installation Position | Shaft Horizontal or Rotor on Bottom (Rotor on Top on Request) |
| Condensation Drainage Holes | On Rotor Side |
| Standards & Compliance | UL 1004-1, CSA C22.2 No. 100, CCC, EAC, CE, EN 60335-1, EN 60034-5 |
| RoHS / Environmental Compliance | RoHS3 Compliant |
Applications
ebm-papst A2D250-AD26-05 three-phase AC axial fan is engineered for high-reliability heat dissipation and forced-air circulation across heavy industrial machinery, commercial refrigeration condensers, and power electronics enclosures. It is widely deployed in variable frequency drives (VFDs), high-capacity welding inverters, CNC machine tool cabinets, industrial heat exchangers, and walk-in cold storage evaporator and condenser coils. Its reversible three-phase star motor and chemical-resistant PFA wiring also make it an ideal OEM and MRO replacement for industrial process ovens, transformer cooling banks, and automated factory switchgear.