A2D250-AD26-05 ebm-papst 400/480VAC 250mm AC Axial Fan

$514.05

ebm-papst A2D250-AD26-05 (A2D250AD2605) 400/480VAC Ø250mm 3-phase axial fan, 2520/2920RPM, 745/850CFM, 150/230W, with black steel sickle blades, PFA AWG20 & IP44.

SKU: A2D250-AD26-05 Category: Brand:

Description

ebm-papst A2D250-AD26-05 (also known as A2D250AD2605) is a heavy-duty S-series three-phase AC axial fan engineered around the M2D068-DC external rotor motor with a 250 mm (9.84 in) impeller diameter and 83.00 mm (3.27 in) axial depth. Operating on 400 VAC (50 Hz) / 480 VAC (60 Hz) star (Y) three-phase power, it delivers a nominal speed of 2520 RPM (50 Hz) / 2920 RPM (60 Hz) at 150 W / 230 W and 0.26 A / 0.32 A, while achieving a maximum free-air flow of 745 CFM (1265 m³/h) at 50 Hz and 850 CFM (1450 m³/h) at 60 Hz.

Designed for demanding industrial thermal environments, the fan features 5 black-painted sheet steel sickle-shaped blades with “V” airflow direction and reversible rotation by swapping two supply phases. It is equipped with precision ball bearings for S1 continuous duty, IP44 ingress protection, Class F insulation, H1+/F2-2 environmental rating, rotor-side condensation drainage holes, and a lateral PFA AWG20 4-wire harness terminated with crimped splices.

Key Features

  • Three-Phase Star (Y) Performance: Operates on 400 VAC (50 Hz) / 480 VAC (60 Hz) power, delivering up to 850 CFM (1450 m³/h) free-air flow.
  • Reversible Rotational Direction: Standard counterclockwise rotation (viewed toward rotor) easily reverses to clockwise by swapping L1 and L2 phases.
  • Aerodynamic S-Series Impeller: Five black-painted sheet steel sickle-shaped blades optimize static pressure build-up and acoustic efficiency in “V” airflow.
  • Industrial Environmental Durability: IP44 degree of protection, H1+/F2-2 moisture and environmental class, Class F insulation, and rotor-side drainage holes.
  • High-Temp PFA Lead Harness: Lateral exit 20 AWG PFA-insulated 4-conductor cable pre-fitted with crimped splice terminals and protective earth.
  • Global Regulatory Compliance: Certified to UL 1004-1, CSA C22.2 No. 100, CCC, EAC, CE, EN 60335-1, and RoHS3 standards.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) A2D250-AD26-05
Alternate Part Number A2D250AD2605
OEM Item Number 12363-5-9980
Integrated Motor Model M2D068-DC (Motor Size 68)
Product Series A2D250 (S Series Sickle-Shaped Blades)
Product Category AC Axial Fans
Fan / Component Type Three-Phase AC Axial Fan (Unshrouded Impeller)
Motor Design / Technology 3-Phase AC External Rotor Induction Motor
Phase & Supply Type 3~ (Three-Phase Star / Y Connection)
Rated Voltage 400 VAC (50 Hz) / 480 VAC (60 Hz)
Curve Test Voltage 400 VAC (50 Hz) / 460 VAC (60 Hz)
Frequency 50 / 60 Hz
Speed (RPM) 2520 RPM (50 Hz) / 2920 RPM (60 Hz) (Customer Spec Nominal)
Free-Air Speed (RPM) 2585 RPM (at 400 VAC, 50 Hz) / 2955 RPM (at 460 VAC, 60 Hz)
Power Rating 150 W (50 Hz) / 230 W (60 Hz) (Customer Spec Nominal)
Free-Air Power Input 137 W (at 400 VAC, 50 Hz) / 215 W (at 460 VAC, 60 Hz)
Rated Current 0.26 A (50 Hz) / 0.32 A (60 Hz) (Customer Spec Nominal)
Free-Air Current Draw 0.25 A (at 400 VAC, 50 Hz) / 0.33 A (at 460 VAC, 60 Hz)
Operating Mode / Duty Cycle S1 (Continuous Duty)
Airflow (Max. Free Air) 745 CFM (1265 m³/h) at 50 Hz / 850 CFM (1450 m³/h) at 60 Hz (at 0 Pa / 0.00 in H₂O)
Max. Static Pressure 0.743 in H₂O (185.0 Pa)
Aerodynamic Measurement Standard ISO 5801 Installation Category A (Measurements LU-30683-1 & LU-30685-1)
Acoustic Measurement Standard ISO 13347 (Sound Power) / 1 m Distance from Fan Axis (Sound Pressure)
Airflow Direction “V” (Intake Over Rotor / Exhaust Over Struts)
Ingress Protection (IP) IP44 (Installation- and Position-Dependent per EN 60034-5)
Moisture / Environmental Class H1+ / F2-2
Min. Ambient Operating Temperature -25 °C (-13 °F)
Storage / Transport Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Motor & Drive Protection No Factory-Installed Overheating Protection (External Motor Protection Required per EN 60335-1)
Electrical Protection Class Class I (With Customer Connection of Protective Earth)
Touch Current (IEC 60990) < 0.75 mA (Measuring Circuit Fig. 4, TN System)
Insulation Class Class “F”
Termination Type 4 Wire Leads with Crimped Splice Terminals
Cable Exit Orientation Lateral
Lead Wire Gauge & Spec PFA Insulated, 20 AWG, 4x Crimped Splices
Wiring Pinout (Counterclockwise) 3~ Star (Y): L1 = V1 (Blue), L2 = U1 (Black), L3 = W1 (Brown), PE = Green/Yellow
Wiring Pinout (Clockwise Reversed) 3~ Star (Y): L1 = U1 (Black), L2 = V1 (Blue), L3 = W1 (Brown), PE = Green/Yellow
Impeller Size Ø 250 mm (9.84 in)
Outer Dimensions (Ø × D) Ø 250 × 83.00 mm (Ø 9.84 × 3.27 in)
Total Axial Depth 83.00 mm (3.27 in)
Max. Screw Clearance 5 mm (0.20 in)
Weight 2.14 kg (4.72 lbs)
Blade Count & Geometry 5 Sickle-Shaped Blades (S Series)
Bearing Type Ball Bearing
Impeller / Blade Material Sheet Steel, Painted Black
Rotor Surface Painted Black
Direction of Rotation Counterclockwise, Viewed Toward Rotor (Reversible by Swapping Two Phases)
Installation Position Shaft Horizontal or Rotor on Bottom (Rotor on Top on Request)
Condensation Drainage Holes On Rotor Side
Standards & Compliance UL 1004-1, CSA C22.2 No. 100, CCC, EAC, CE, EN 60335-1, EN 60034-5
RoHS / Environmental Compliance RoHS3 Compliant

Applications

ebm-papst A2D250-AD26-05 three-phase AC axial fan is engineered for high-reliability heat dissipation and forced-air circulation across heavy industrial machinery, commercial refrigeration condensers, and power electronics enclosures. It is widely deployed in variable frequency drives (VFDs), high-capacity welding inverters, CNC machine tool cabinets, industrial heat exchangers, and walk-in cold storage evaporator and condenser coils. Its reversible three-phase star motor and chemical-resistant PFA wiring also make it an ideal OEM and MRO replacement for industrial process ovens, transformer cooling banks, and automated factory switchgear.