Description
ebm-papst R4D400-AL17-05 (also known as R4D400AL1705, OEM item number 12465-5-9980) is a heavy-duty 400 mm (15.75 in) single-inlet, backward-curved AC motorized centrifugal impeller powered by an integrated 3-phase M4D110-GF external rotor motor.
Engineered for high-temperature industrial ventilation and precision air handling, it measures Ø404 × 217.5 mm (15.91 × 8.56 in) overall and features a 6-blade sheet aluminum impeller paired with a cast aluminum rotor surface and precision ball bearings.
Operating on 3-phase Delta (Δ) 400 VAC (50 Hz) or 480 VAC (60 Hz) supplies, this unit delivers up to 2,398.5 CFM (4,075 m³/h) at 50 Hz and 2,848.7 CFM (4,840 m³/h) at 60 Hz free air, maintaining nominal maximum-load operation at 1,405 RPM (450 W, 1.01 A) at 50 Hz and 1,655 RPM (740 W, 1.22 A) at 60 Hz. Built to withstand extreme thermal environments from -40 °C up to +100 °C (+212 °F) at 50 Hz (+80 °C at 60 Hz), it incorporates IP54 ingress protection, Class F insulation, F3-1 humidity rating, external thermal overload protector (TOP) leads, and a 600 mm high-temperature 6G 0.5 mm² silicone connection cable.
Key Features
- High-Static Backward-Curved Aerodynamics: Six-blade sheet aluminum impeller delivers up to 2,848.7 CFM (4,840 m³/h) free-air flow and 550 Pa duty pressure.
- Three-Phase Dual-Frequency Motor: Integrated M4D110-GF Delta-connected motor runs on 400 VAC (50 Hz) at 1,405 RPM or 480 VAC (60 Hz) at 1,655 RPM.
- Extreme +100 °C Thermal Endurance: Rated for continuous S1 operation from -40 °C to +100 °C (50 Hz) or +80 °C (60 Hz) with high-temperature silicone cabling.
- IP54 &F3-1 Environmental Sealing: Cast-in-aluminum rotor, Class F insulation, and rotor-side condensate drainage holes protect against moisture and industrial dust.
- External Thermal Overload Protection: Dedicated dual grey TOP leads allow direct integration with external motor circuit breakers and PLC safety interlocks.
- ErP Directive Static Efficiency: Achieves 48.7% overall static efficiency (Grade N = 62.8), exceeding EU ErP 2015 regulatory efficiency benchmarks.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | R4D400-AL17-05 |
| Alternate Part Number | R4D400AL1705 |
| OEM Item Number | 12465-5-9980 (Revision 75933) |
| Integrated Motor Model | M4D110-GF |
| Product Series | R4D400 |
| Product Category | AC Centrifugal Fans |
| Fan / Component Type | Backward-Curved Single-Inlet Motorized Impeller (Unhoused) |
| Motor Design / Technology | 3-Phase AC External Rotor Induction Motor (4-Pole) |
| Phase & Supply Type | 3~ (Three-Phase AC, Delta Δ Connection) |
| Rated Voltage | 400 VAC (50 Hz) / 480 VAC (60 Hz) |
| Frequency | 50 Hz / 60 Hz |
| Speed (Max. Load / Point 3) | 1405 RPM (50 Hz at 320 Pa) / 1655 RPM (60 Hz at 450 Pa) |
| Free-Air Speed (Point 1) | 1430 RPM (50 Hz at 0 Pa) / 1695 RPM (60 Hz at 0 Pa) |
| Intermediate Duty Speed (Point 2) | 1415 RPM (50 Hz at 180 Pa) / 1670 RPM (60 Hz at 250 Pa) |
| High-Pressure Duty Speed (Point 4) | 1410 RPM (50 Hz at 400 Pa) / 1665 RPM (60 Hz at 550 Pa) |
| ErP Optimum Efficiency Speed | 1405 RPM (50 Hz at 330 Pa) |
| Power Rating (Max. Load / Point 3) | 450 W (50 Hz) / 740 W (60 Hz) |
| Free-Air Power Input (Point 1) | 348 W (50 Hz) / 558 W (60 Hz) |
| Intermediate Duty Power Input (Point 2) | 409 W (50 Hz) / 675 W (60 Hz) |
| High-Pressure Duty Power Input (Point 4) | 420 W (50 Hz) / 701 W (60 Hz) |
| ErP Optimum Efficiency Power | 450 W / 0.45 kW (50 Hz) |
| Rated Current (Max. Load / Point 3) | 1.01 A (50 Hz at 400 VAC) / 1.22 A (60 Hz at 480 VAC) |
| Free-Air Current Draw (Point 1) | 0.84 A (50 Hz at 400 VAC) / 0.96 A (60 Hz at 480 VAC) |
| Intermediate Duty Current Draw (Point 2) | 0.89 A (50 Hz at 400 VAC) / 1.08 A (60 Hz at 480 VAC) |
| High-Pressure Duty Current Draw (Point 4) | 0.90 A (50 Hz at 400 VAC) / 1.11 A (60 Hz at 480 VAC) |
| Inrush / Starting Current | 4.89 A (50 Hz) / 5.43 A (60 Hz) |
| Operating Mode / Duty Cycle | S1 (Continuous Duty) |
| Airflow (Max. Free Air / Point 1) | 2398.5 CFM (4075 m³/h at 50 Hz) / 2848.7 CFM (4840 m³/h at 60 Hz) |
| Operating Duty Point 2 Airflow | 1918.8 CFM (3260 m³/h) at 0.723 in H₂O (180 Pa, 50 Hz) / 2257.2 CFM (3835 m³/h) at 1.005 in H₂O (250 Pa, 60 Hz) |
| Operating Duty Point 3 Airflow (Nominal Max. Load) | 1503.8 CFM (2555 m³/h) at 1.286 in H₂O (320 Pa, 50 Hz) / 1786.3 CFM (3035 m³/h) at 1.808 in H₂O (450 Pa, 60 Hz) |
| Operating Duty Point 4 Airflow | 1077.1 CFM (1830 m³/h) at 1.607 in H₂O (400 Pa, 50 Hz) / 1356.7 CFM (2305 m³/h) at 2.210 in H₂O (550 Pa, 60 Hz) |
| ErP Optimum Efficiency Duty Point | 1415.5 CFM (2405 m³/h) at 1.326 in H₂O (330 Pa, 50 Hz) |
| Max. Operating Curve Static Pressure (Point 4) | 1.607 in H₂O (400 Pa at 50 Hz) / 2.210 in H₂O (550 Pa at 60 Hz) |
| Max. Static Pressure (Chart Curve Limit) | 1.808 in H₂O (450 Pa at 50 Hz, LU-135131) / 2.572 in H₂O (640 Pa at 60 Hz, LU-135148) |
| Min. Back Pressure | 0 in H₂O (0 Pa) |
| ErP Efficiency & Grade (EU 327/2011) | Overall Static Efficiency ηes = 48.7% (2015 Target: 47.9%), Efficiency Grade N = 62.8 (2015 Target: 62), Installation Category A, Static, Specific Ratio = 1.00, No VSD |
| Airflow Direction | Axial Intake, Radial Centrifugal Discharge |
| Ingress Protection (IP) | IP54 |
| Moisture / Environmental Class | F3-1 |
| Operating Temperature (50 Hz) | -40 °C to +100 °C (-40 °F to +212 °F) |
| Operating Temperature (60 Hz) | -40 °C to +80 °C (-40 °F to +176 °F) |
| Storage Temperature | -40 °C to +100 °C (-40 °F to +212 °F) |
| Motor & Drive Protection | Thermal Overload Protector (TOP) wired out to external leads (to be connected by customer) |
| Electrical Protection Class | Class I (with customer-connected protective earth PE) |
| Touch Current (IEC 60990) | <= 3.5 mA (Measuring network Fig. 4, TN system) |
| Insulation Class | Class F |
| Termination Type | High-Temperature Silicone Cable with 6x Crimped Brass Lead Tips |
| Cable Exit Orientation | Axial / Rotor-Backplate Side Exit |
| Lead Wire Gauge & Spec | 6G 0.5 mm² (~20 AWG) Silicone Insulated Multi-Conductor Cable |
| Cable / Lead Length | 600 ±20 mm (23.62 ±0.79 in) |
| Wire Stripped / Tinned Length | 85 ±10 mm (3.35 ±0.39 in) |
| Wiring Pinout / Connection | Delta (Δ): L1 = U1 (Black), L2 = V1 (Blue), L3 = W1 (Brown), TOP = 2x Grey, PE = Green/Yellow |
| Impeller Size | 400 mm (15.75 in) |
| Outer Dimensions (Ø × D) | Ø404 × 217.5 ±2 mm (Ø15.91 × 8.56 ±0.08 in) |
| Impeller Axial Width | 187 mm (7.36 in) |
| Internal Blade Channel Width | 140 mm (5.51 in) |
| Inlet Nozzle / Intake Ring Diameter | Ø268 mm (10.55 in) Impeller Eye Opening with R20 mm (0.79 in) Lip Radius |
| Shaft / Hub Diameter | Ø115 +0.3 mm (4.53 in) Motor Stator Base Diameter |
| Mounting Hole Pitch | Ø140 mm (5.51 in) Bolt Circle Diameter |
| Mounting Hole Diameter / Thread Size | 4 × M6 Threaded Mounting Holes |
| Flange / Wall Thickness | 5.5 mm (0.22 in) Motor Mounting Flange / 1.5 mm (0.06 in) Impeller Shroud |
| Max. Screw Clearance | 12 mm (0.47 in) Max. Screw Thread Depth |
| Weight | 14.5 kg (31.97 lbs) |
| Blade Count & Geometry | 6 Backward-Curved Aerofoil Blades |
| Bearing Type | Ball Bearing |
| Impeller / Blade Material | Sheet Aluminium |
| Rotor Surface | Cast in Aluminium |
| Direction of Rotation | Clockwise, Viewed Toward Rotor |
| Installation Position | Shaft Horizontal or Rotor on Bottom (Rotor on Top Available on Request) |
| Condensation Drainage Holes | Rotor-Side Drainage Holes |
| Compatible Inlet Ring (Optional) | 54476-2-4013 (Not Included in Standard Delivery) |
| Standards & Compliance | CE, VDE, EN 61800-5-1, ISO 5801 (Category A), ISO 13347, ErP 2015 |
Applications
ebm-papst R4D400-AL17-05 unhoused backward-curved centrifugal fans are purpose-built for pressurized plenum installations and high-ambient thermal management systems where elevated air temperatures and static resistance demand rugged all-metal construction. Typical OEM and MRO applications include industrial drying and curing ovens, commercial rooftop HVAC air handling units (AHUs), process heat exchangers, power converter and transformer cooling cabinets, and heavy-duty extraction ventilation hoods. Its compact unhoused design allows direct integration into customer inlet nozzles and modular fan walls across manufacturing plants, commercial buildings, and energy infrastructure.







