GTW017EUB12 Delta 230VAC 200x122mm Round EC Axial Fan

$370.86

Delta GTW017EUB12 200-240VAC Ø200x122mm EC tubeaxial fan, 5800RPM, 693CFM (1177m³/h), 185/240W, featuring 844Pa pressure, 0-10V/PWM control, FG tach & IP54.

SKU: GTW017EUB12 Category: Brand:

Description

Delta GTW017EUB12 is a heavy-duty round electronically commutated (EC) tubeaxial cooling fan featuring a Ø200.0 × 122.0 mm (7.874 × 4.803 in) die-cast aluminum housing and high-efficiency plastic impeller. Operating across a single-phase 200 to 240 VAC (50/60 Hz) supply, this high-pressure axial fan delivers 693 CFM (1177 m³/h) of free-air airflow at 5800 RPM (185 W free-air input; 240 W / 1.25 A maximum label rating) and overcomes steep system impedance up to 3.39 in H₂O (844 Pa) of shutoff static pressure.

Engineered for demanding industrial environments, it integrates dual ball bearings rated for 60,000 hours at 40 °C, an IP54 dust- and splash-resistant enclosure, dual UL2464 power and control cables (0–10 VDC / PWM speed input, +12 VDC auxiliary output, and 2-pulse FG tachometer), plus soft start, locked-rotor, and over-temperature protection.

Key Features

  • High-Pressure EC Aerodynamics: Generates 693 CFM (1177 m³/h) maximum airflow and an exceptional 3.39 in H₂O (844 Pa) static pressure.
  • Wide-Range AC Input: Operates directly on single-phase 200–240 VAC (50/60 Hz) power with high-efficiency brushless EC motor commutation.
  • Flexible Speed & Tach Interface: Supports 0–10 VDC analog or 100 Hz–100 kHz PWM control, onboard +12 VDC output, and FG tachometer feedback.
  • Rugged Die-Cast Construction: Combines a corrosion-resistant die-cast aluminum venturi frame, aerodynamic plastic impeller, and precision dual ball bearings.
  • IP54 & Comprehensive Protection: Sealed to IP54 environmental standards with soft start, automatic locked-rotor protection, and thermal overload protection.
  • Dual Pre-Wired UL2464 Harnesses: Supplied with dedicated 18 AWG AC power leads and 24 AWG control leads terminated with ferrules.

Technical Specifications

Manufacturer Delta
Manufacturer Part Number (MPN) GTW017EUB12
Safety Model Number GTW017EUB12
Product Series GTW Series
Product Category AC Axial Fans
Fan / Component Type Round EC Tubeaxial Cooling Fan
Motor Design / Technology Electronically Commutated (EC) Brushless Motor
Phase & Supply Type 1~ Single-Phase AC Input
Rated Voltage 200 – 240 VAC
Frequency 50 / 60 Hz
Speed (RPM) 5800 RPM ±5% (Nominal Full Speed at 10 VDC / 100% PWM)
Free-Air Speed (RPM) 5770 RPM (Measured at 0 Pa Free Air)
Half-Duty Speed (50% PWM / 5 VDC) 3550 RPM ±8%
Shutoff Speed (at Max. Pressure) 5478 RPM (Measured at 844 Pa Shutoff)
Power Rating (Max. Load / Label) 240 W
Free-Air Power Input 185 W (at 0 Pa, 1177 m³/h)
Shutoff Power Input (at Max. Pressure) 235 W (at 844 Pa, 0 m³/h)
Rated Current (Max. Label) 1.25 A
Free-Air Current Draw 0.9 A (at 0 Pa, 1177 m³/h)
Intermediate Load Current Draw 1.0 A (at 268 – 583 Pa)
Shutoff Current Draw (at Max. Pressure) 1.1 A (at 844 Pa, 0 m³/h)
Airflow (Max. Free Air) 693.0 CFM (1177 m³/h / 19.62 m³/min at 0 Pa)
Operating Duty Point 2 (P-Q Curve) 560.3 CFM (952 m³/h) at 1.08 in H₂O (268 Pa), 5650 RPM, 203 W, 1.0 A
Operating Duty Point 3 (P-Q Curve) 410.2 CFM (697 m³/h) at 1.97 in H₂O (491 Pa), 5653 RPM, 207 W, 1.0 A
Operating Duty Point 4 (P-Q Curve) 285.5 CFM (485 m³/h) at 1.92 in H₂O (479 Pa), 5757 RPM, 189 W, 0.9 A
Operating Duty Point 5 (P-Q Curve) 132.4 CFM (225 m³/h) at 2.34 in H₂O (583 Pa), 5670 RPM, 205 W, 1.0 A
Max. Static Pressure 3.39 in H₂O (844.0 Pa / 86.06 mmH₂O)
Free-Air Sound Pressure Level (Intake) 70.5 dB(A) (Measured at 1 m from intake side, Free Air)
Ingress Protection (IP) IP54 (Dust Protected, Splash Water Resistant)
Operating Temperature -25 °C to +60 °C (-13 °F to +140 °F)
Storage Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Test & Operating Humidity 15% to 65% RH
Service Life L10 (at 40 °C) 60,000 hours (at 40 °C, 15 – 65% RH)
Motor & Drive Protection Locked Rotor Protection, Soft Start, Over-Temperature Protection (TOP)
Electrical Protection Class Class I (with Protective Earth)
Touch / Leakage Current ≤ 3.5 mA
Insulation Class Class A
Control / Signal Features 0–10 VDC Analog Speed Control, PWM Speed Control, FG Tachometer Output, +12 VDC Auxiliary Output, Full-Speed Shorting Mode (Red + Yellow)
Analog Voltage Control Spec 0 – 10 VDC (Start-up > 1.5 VDC; Full Speed at 10 VDC)
PWM Duty Control Spec 10 VDC ±5% Amplitude, 100 Hz – 100 kHz Frequency (Start-up > 15% Duty; Full Speed at 100% Duty)
Auxiliary DC Output +12 VDC ±10% (Max. 5 mA)
Tachometer (FG) Signal Spec Open-Collector Output, 2 Pulses/Rev (VFG ≤ 20.0 VDC Max., Ic ≤ 5 mA Max., Vce(sat) ≤ 0.7 V Max.)
Termination Type Dual Jacketed Cables with 7 Wire Leads and Ferrules (3 Power Leads + 4 Control Leads)
Power Lead Wire Gauge & Spec (Cable 2) UL2464 18 AWG (3 Conductors)
Control Lead Wire Gauge & Spec (Cable 1) UL2464 24 AWG (4 Conductors)
Cable / Lead Length 470.0 ± 10.0 mm (18.504 ± 0.394 in)
Power Wiring Pinout (Cable 2) Brown = Line / AC Main (200–240 VAC), Blue = Neutral / AC Main (200–240 VAC), Green/Yellow = Protective Earth (PE)
Control & Signal Pinout (Cable 1) Red = +12 VDC Output (Max. 5 mA), Yellow = Speed Control (0–10 VDC / PWM), White = FG Tachometer Output, Green = Ground (GND)
Outer Dimensions (Ø × D) Ø200.0 ± 0.5 × 122.0 mm (Ø7.874 ± 0.020 × 4.803 in)
Total Axial Depth (Split Sections) 122.0 mm Total: 70.0 ± 0.5 mm (2.756 ± 0.020 in) Intake Section + 52.0 ± 0.5 mm (2.047 ± 0.020 in) Exhaust Section
Flange / Wall Thickness 8.0 ± 0.3 mm (0.315 ± 0.012 in) on Both Ends
Shaft / Hub Diameter Ø92.0 mm (Ø3.622 in REF.)
Mounting Hole Diameter / Count 4 × Ø4.5 mm (4 × Ø0.177 in) per Flange
Weight 2.7 kg (5.95 lbs)
Bearing Type Dual Ball Bearings
Housing / Frame Material Die-Cast Aluminum
Impeller / Blade Material Molded Plastic
Direction of Rotation Counter-Clockwise (CCW) Viewed on Rotor
EMC Standards EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3
Standards & Compliance UL, CSA (cURus), TUV, CE
RoHS / Environmental Compliance RoHS Compliant

Applications

Delta GTW017EUB12 round EC tubeaxial cooling fan is engineered for high-impedance thermal management in heavy-duty power electronics, industrial automation cabinets, and telecommunications infrastructure. Its steep static pressure curve and IP54 environmental sealing make it ideal for cooling densely packed variable frequency drives (VFDs), solar and wind power inverters, uninterruptible power supply (UPS) rectifiers, and outdoor telecom base station enclosures. OEM system integrators and MRO technicians deploy this unit in closed-loop equipment ventilation plenums where variable demand-based speed modulation and continuous tachometer monitoring are required.