ASB0305LA-DR00 Delta 5VDC 30x30x10mm Axial Cooling Fan

$6.06

Delta ASB0305LA-DR00 (ASB0305LADR00) 5VDC 30x10mm axial fan, 8000RPM, 3.21CFM, 0.50W, featuring an integrated locked-rotor sensor (RD) & sleeve bearing.

SKU: ASB0305LA-DR00 Category: Brand:

Description

Delta Electronics ASB0305LA-DR00 (also known as ASB0305LADR00) is a compact 30x30x10 mm (1.181×1.181×0.394 in) DC brushless tubeaxial cooling fan designed for ultra-dense embedded thermal management. Operating from a nominal 5.0 VDC supply (4.5 to 5.5 VDC range), it delivers 3.21 CFM (5.46 m³/h) of airflow and 0.131 in H₂O (32.6 Pa) of static pressure at 8000 RPM while consuming just 0.50 W. Built with flame-retardant UL 94V-0 plastic housing and impeller assemblies, the fan features an integrated open-collector rotation detect (RD) locked-rotor alarm wire, impedance motor protection, and reverse polarity tolerance. Electrical connection is established via three 150 mm UL 1061 AWG #28 lead wires for straightforward integration into low-profile electronics.

Key Features

  • Precision Aerodynamic Design: Delivers 3.21 CFM airflow and 32.6 Pa static pressure within an ultra-compact 30 mm square frame.
  • Low-Power 5VDC Motor: Consumes only 0.50 W nominal power draw with an efficient operating voltage window of 4.5–5.5 VDC.
  • Integrated Lock Sensor (RD): Features a dedicated third blue wire open-collector rotation detection circuit for real-time rotor fault monitoring.
  • Robust Electrical Protection: Engineered with 96-hour locked rotor impedance protection and comprehensive reverse supply polarity tolerance.
  • UL 94V-0 Rated Construction: Fabricated from flame-retardant thermoplastic housing and impeller materials for demanding commercial and industrial deployments.

Technical Specifications

Manufacturer Delta
Manufacturer Part Number (MPN) ASB0305LA-DR00
Alternate Part Number ASB0305LADR00
Product Series ASB Series
Product Category DC Axial Fans
Fan / Component Type DC Brushless Tubeaxial Fan
Supply Type DC
Rated Voltage 5.0 VDC
Operating Voltage Range 4.5 to 5.5 VDC
Min. Starting Voltage 4.0 VDC Max
Rated Speed (RPM) 8000 RPM (±15%)
Rated Power Rating 0.50 W
Max. Input Power 0.85 W
Rated Current 0.10 A
Max. Current Draw 0.17 A
Safety Label Current 0.17 A
Airflow 3.21 CFM (5.46 m³/h, 0.091 m³/min)
Min. Airflow at Zero Static Pressure 2.73 CFM (4.64 m³/h, 0.077 m³/min)
Static Pressure 0.131 in H₂O (32.6 Pa, 3.33 mmH₂O)
Min. Static Pressure at Zero Airflow 0.094 in H₂O (23.5 Pa, 2.40 mmH₂O)
Noise Level 21.0 dB(A)
Max. Noise Level 25.5 dB(A)
Acoustic Test Distance 1.0 m in Free Air Anechoic Chamber
Dimensions (L × H × D) 30.0 × 30.0 × 10.0 mm (1.181 × 1.181 × 0.394 in)
Mounting Hole Pitch 24.0 ± 0.3 mm (0.945 ± 0.012 in)
Mounting Hole Diameter 4 × Ø3.2 ± 0.3 mm (Ø0.126 ± 0.012 in)
Housing Material Plastic (UL 94V-0)
Impeller Material Plastic (UL 94V-0)
Bearing Type Sleeve Bearing
Direction of Rotation Counterclockwise (CCW) viewed from air flow inlet
Weight 7.4 g (0.0163 lbs / 0.26 oz)
Termination & Cable Specs 3 Wire Leads, UL 1061 AWG #28, Length 150.0 ± 10.0 mm (5.906 ± 0.394 in), Twisted 2–3 Turns
Wiring Pinout / Connection Red: Positive (+), Black: Negative (-), Blue: Lock Signal (-R00 / RD)
Rotation Detect (RD) Circuit Mode Open Collector Mode
RD Signal Collector Voltage (Vce) 5.5 VDC Max
RD Signal Collector Current (Ic) 5 mA Max
RD Saturation Voltage (Vce sat) 0.5 V Max
Motor Protection Locked Rotor Impedance Protection (96 Hours at Rated Voltage)
Polarity Protection Reverse Polarity Withstanding Protection
Insulation Class UL: Class A
Insulation Resistance 10 MΩ Min. at 500 VDC (between frame and (+) terminal)
Dielectric Strength 5 mA Max. at 500 VAC 50/60 Hz for 1 Minute (between frame and (+) terminal)
Operating Temperature -10 to +70 °C (14 to 158 °F)
Storage Temperature -40 to +75 °C (-40 to 167 °F)
Operating Humidity 5 to 90 % RH
Storage Humidity 5 to 95 % RH
Service Life (L10) 20,000 Hours Continuous Operation at 40 °C, 65% RH
Standards & Compliance cURus, TUV, RoHS Compliant, Zero ODS (No PBBs, PBBOs, CFCs, PBBEs, PBDPEs, HCFCs)

Applications

Delta ASB0305LA-DR00 axial cooling fans are engineered specifically for highly constrained thermal cavities across edge-computing hardware, network appliance routers, and embedded single-board computers. They provide vital localized forced-air spot cooling across optical transceiver cages, telecom transponders, power conversion modules, and portable medical diagnostic equipment. System engineers and maintenance technicians also deploy this compact assembly as a direct-fit replacement for low-profile industrial instrumentation, barcode scanners, and handheld analytical devices requiring active rotor-lock telemetry.

Reviews

There are no reviews yet.

Be the first to review “ASB0305LA-DR00 Delta 5VDC 30x30x10mm Axial Cooling Fan”

Your email address will not be published. Required fields are marked *