AFB0912HH-AF00 Delta 12VDC 92x92x25.4mm DC Axial Fan

$14.44

Delta AFB0912HH-AF00 (AFB0912HHAF00) 12VDC 92x92x25.4mm DC axial fan, 3300RPM, 72.74CFM (0.262inH₂O), 3.84W, featuring dual ball bearings & FG tach output.

SKU: AFB0912HH-AF00 Category: Brand:

Description

Delta AFB0912HH-AF00 (also known as AFB0912HHAF00) is an industrial-grade brushless DC tubeaxial cooling fan engineered in a compact 92.0 × 92.0 × 25.4 mm (3.622 × 3.622 × 1.000 in) square frame with an 82.5 mm (3.248 in) mounting hole pitch. Operating on a nominal 12.0 VDC supply across a wide 5.0 to 13.8 VDC voltage range, this model runs at 3300 RPM while drawing 0.32 A (3.84 W nominal, 4.80 W max) to deliver 72.74 CFM (123.6 m³/h) of free-air airflow and 0.262 in H₂O (65.2 Pa) of maximum static pressure.

Built with a flame-retardant UL 94V-0 plastic housing and impeller supported by precision dual ball bearings, the unit achieves a 70,000-hour continuous operational life at 40 °C. It terminates in 310 mm (12.205 in) 3-wire UL 1007 AWG #24 leads featuring an open-collector Frequency Generator (F00) tachometer signal, locked-rotor current shutdown with 96-hour burn-out protection, and reverse polarity protection.

Key Features

  • High-Density Axial Airflow: Delivers 72.74 CFM (123.6 m³/h) maximum airflow and 0.262 in H₂O (65.2 Pa) static pressure at 3300 RPM.
  • Open-Collector Tachometer Output: Dedicated blue F00 lead outputs a 4-pole frequency generator signal (13.8 VDC max, 5 mA max) for RPM telemetry.
  • Dual Ball Bearing Longevity: Precision two-ball-bearing suspension supports continuous operation for 70,000 hours at 40 °C ambient temperature.
  • Comprehensive Motor Safeguards: Integrates locked-rotor current shutdown (96-hour fire protection), over-current cutoff, and reverse polarity protection.
  • Flame-Retardant UL 94V-0 Build: Molded from UL 94V-0 thermoplastic with dual 4.0 mm flanges and eight Ø4.5 mm mounting holes.

Technical Specifications

Manufacturer Delta
Manufacturer Part Number (MPN) AFB0912HH-AF00
Alternate Part Number AFB0912HHAF00
Product Series AFB Series
Product Category DC Axial Fans
Fan / Component Type DC Brushless Tubeaxial Cooling Fan
Motor Design / Technology 4-Pole Electronically Commutated Brushless DC Motor
Phase & Supply Type DC Supply
Rated Voltage 12.0 VDC
Operating Voltage Range 5.0 to 13.8 VDC
Min. Starting Voltage 5.0 VDC (at 25 °C / 77 °F)
Speed (RPM) 3300 RPM (±10%)
Power Rating 3.84 W (Nominal)
Max. Input Power 4.80 W
Rated Current 0.32 A (Nominal)
Max. Current Draw 0.40 A
Operating Mode / Duty Cycle Continuous Operation
Airflow (Max. Free Air) 72.74 CFM (123.6 m³/h / 2.060 m³/min) at 0 Pa
Min. Guaranteed Free-Air Airflow 65.47 CFM (111.2 m³/h / 1.854 m³/min) at 0 Pa
Max. Static Pressure 0.262 in H₂O (65.2 Pa / 6.65 mmH₂O) at 0 CFM
Min. Guaranteed Static Pressure 0.212 in H₂O (52.9 Pa / 5.39 mmH₂O) at 0 CFM
Sound Pressure Level (Intake) 42.5 dB(A) Avg. (at 1 m in free air)
Max. Sound Pressure Level 46.5 dB(A) Max. (at 1 m in free air)
Airflow Direction Intake over struts / Exhaust over label side
Operating Temperature -10 to 70 °C (14 to 158 °F)
Storage Temperature -40 to 75 °C (-40 to 167 °F)
Operating Humidity 5% to 90% RH
Storage Humidity 5% to 95% RH
Service Life L10 (at 40 °C) 70,000 hours (Continuous at 40 °C / 104 °F, 15% to 65% RH)
High-Temperature Endurance Test >= 1,000 hours continuous at 70 °C (158 °F) max. operating temperature
Vibration Resistance 3.2 gRMS overall (10 to 1000 Hz, 2 hours per X/Y/Z axis, non-operating at 25 °C)
Mechanical Shock Resistance 20 G min. (11 ms half-sine wave, 5 shocks per X/Y/Z axis, non-operating at 20 °C)
Thermal Cycling Qualification -40 to +80 °C (-40 to 176 °F), 30 min soak, < 5 min transition, 5 cycles
Motor & Drive Protection Locked-Rotor Current Shutdown (96-hr Impedance Protection), Over-Current Shutdown, Auto-Restart, Reverse Polarity Protection
Insulation Class UL Class A
Insulation Resistance >= 10 MΩ at 500 VDC (between frame and + terminal)
Dielectric Strength 500 VAC at 60 Hz for 1 minute (<= 5 mA leakage between frame and + terminal)
Control / Signal Features Frequency Generator (FG / F00) Tachometer Output (4-Pole Open Collector)
Tachometer Output Ratings Open Collector: V_FG <= 13.8 VDC, I_c <= 5 mA, V_CE(sat) <= 0.5 VDC
Termination Type 3 Wire Leads
Lead Wire Gauge & Spec 3 × AWG #24, UL 1007 -F-
Cable / Lead Length 310.0 ±10.0 mm (12.205 ±0.394 in)
Wire Stripped / Tinned Length 10.0 mm (0.394 in)
Wiring Pinout / Connection Red = Positive (+), Black = Negative (-), Blue = Frequency Generator (F00 / Tachometer)
Dimensions (L × H × D) 92.0 ±0.5 × 92.0 ±0.5 × 25.4 ±0.5 mm (3.622 ±0.020 × 3.622 ±0.020 × 1.000 ±0.020 in)
Mounting Hole Pitch 82.5 ±0.3 mm (3.248 ±0.012 in)
Mounting Hole Diameter / Thread Size 8 × Ø4.5 ±0.3 mm (Ø0.177 ±0.012 in)
Flange / Wall Thickness 4.0 ±0.3 mm (0.157 ±0.012 in) per mounting flange
Weight 0.120 kg (0.265 lbs / 120 g)
Bearing Type Dual Ball Bearings (Two Ball Bearings)
Housing / Scroll / Frame Material Thermoplastic, UL 94V-0
Impeller / Blade Material Thermoplastic, UL 94V-0
Direction of Rotation Clockwise (viewed from nameplate side)
Standards & Compliance UL, CSA, VDE, CE
RoHS / Environmental Compliance RoHS3 Compliant, Ozone-Depleting Substances Free (No PBBs, PBBOs, CFCs, PBBEs, PBDPEs, HCFCs)

Applications

Delta AFB0912HH-AF00 brushless tubeaxial fan is deployed across industrial automation cabinets, telecom rectifiers, and high-density power electronics requiring continuous forced-air cooling with real-time rotational speed monitoring. Its standard square footprint and open-collector tachometer output make it an ideal OEM thermal subsystem and MRO drop-in replacement for variable frequency drives (VFDs), CNC servo controllers, uninterruptible power supplies (UPS), rackmount network switches, and medical diagnostic instruments. The dual ball bearing architecture and locked-rotor impedance protection ensure dependable operation inside enclosed machinery, inverter housings, and automated test equipment.