Description
ebm-papst 6424 (OEM Item No. 9295414301, specification code VWLG150XJLPS) is an industrial 6400 Series brushless DC tubeaxial fan engineered with a truncated round Ø172.0 × 150.0 × 51.0 mm (6.77 × 5.91 × 2.01 in) metal wall-ring frame and plastic impeller. Operating on a nominal 24 VDC supply across a wide 12 to 28 VDC voltage window, it runs at 3400 RPM (17 W, 710 mA at free air) to deliver 229.5 CFM (390.0 m³/h) of airflow over outlet struts and up to 0.755 in H₂O (188 Pa) of static pressure.
Designed for continuous industrial service in any shaft orientation, the unit incorporates spring-preloaded dual ball bearings rated for an L10 life of 75,000 hours at 40 °C (127,500 hours per IPC 9591) across an ambient temperature range of -20 °C to +72 °C (-4 °F to +161.6 °F). Integrated motor protection includes a reverse-polarity rectifying diode and locked-rotor auto-restart electronics, paired with an integrated 2-pin flat plug connector and UL 507, CSA, VDE, CE, and EAC certifications.
Key Features
- High-Airflow Axial Output: Delivers 229.5 CFM (390.0 m³/h) free-air flow and 0.755 in H₂O (188 Pa) static pressure at 3400 RPM.
- Wide 12–28 VDC Operation: Supports flexible voltage regulation from 1750 RPM (3.1 W) at 12 VDC up to 3850 RPM (26 W) at 28 VDC.
- Rugged Metal Housing: Truncated Ø172 × 150 × 51 mm metal frame resists mechanical distortion up to 260 Ncm flange mounting torque.
- Integrated Motor Protection: Built-in rectifying diode guards against reverse polarity alongside electronic locked-rotor current limiting and auto-restart.
- Preloaded Ball Bearings: Spring-preloaded zero-axial-clearance ball bearing system achieves 75,000 hours L10 life at 40 °C in any mounting orientation.
- Plug-In Termination & Approvals: Integrated 3.0 × 0.8 mm flat plug terminals with UL 507, VDE EN 62368, CSA, CE, and EAC compliance.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | 6424 |
| OEM Item Number | 9295414301 (Spec Code: VWLG150XJLPS) |
| Product Series | 6400 Series |
| Product Category | DC Axial Fans |
| Fan / Component Type | DC Tubeaxial Cooling Fan with Truncated Wall Ring |
| Motor Design / Technology | Brushless Electronically Commutated DC Motor |
| Phase & Supply Type | DC |
| Rated Voltage | 24 VDC |
| Operating Voltage Range | 12 to 28 VDC |
| Speed (RPM) | 3400 RPM ±10% (at 24 VDC, Free Air) |
| Speed at Min. Voltage | 1750 RPM ±10% (at 12 VDC, Free Air) |
| Speed at Max. Voltage | 3850 RPM ±10% (at 28 VDC, Free Air) |
| Power Rating | 17 W ±25% (at 24 VDC, Free Air) |
| Power Input at Min. Voltage | 3.1 W ±25% (at 12 VDC, Free Air) |
| Power Input at Max. Voltage | 26 W ±20% (at 28 VDC, Free Air) |
| Rated Current | 710 mA / 0.71 A ±25% (at 24 VDC, Free Air) |
| Current Draw at Min. Voltage | 260 mA / 0.26 A ±25% (at 12 VDC, Free Air) |
| Current Draw at Max. Voltage | 755 mA / 0.755 A ±20% (at 28 VDC, Free Air) |
| Inrush / Starting Current | 4000 mA (4.0 A) |
| Locked-Rotor Current | Approx. 4000 mA (at 24 VDC; Clock t3/t4: 1.4 s / 5.3 s typical) |
| Airflow (Max. Free Air) | 229.5 CFM (390.0 m³/h) |
| Optimal Operating Duty Point | 161.9 CFM (275.0 m³/h) at 0.245 in H₂O (61 Pa) |
| Max. Static Pressure | 0.755 in H₂O (188 Pa) |
| Free-Air Sound Pressure Level | 55.0 dB(A) (at 1 m Intake, Measured in Rubber Bands) |
| Sound Power Level (Optimal Point) | 6.4 bel(A) / 64 dB(A) (per DIN 45635-38 / ISO 10302) |
| Airflow Direction | Air Outlet Over Struts |
| Ingress Protection (IP) | IP20 (Pollution Degree 1 per DIN EN 60664-1) |
| Operating Temperature | -20 °C to +72 °C (-4 °F to +161.6 °F) |
| Storage Temperature | -40 °C to +80 °C (-40 °F to +176 °F) |
| Climatic Humidity Rating | Constant Humid Heat, 14 Days (per DIN EN 60068-2-78) |
| Service Life L10 (at 40 °C) | 75,000 Hours |
| Service Life L10 (at Max. Temp) | 35,000 Hours (at 72 °C) |
| Service Life L10IPC | 127,500 Hours (at 40 °C per IPC 9591) |
| Motor & Drive Protection | Reverse Polarity Rectifying Diode (IF <= 10 mA), Locked-Rotor Protection with Auto-Restart |
| Electrical Protection Class | Class III |
| Insulation Resistance | > 10 MΩ (at 500 VDC for 1 min after 48h at 95% RH, 25 °C) |
| Dielectric Strength | 500 VAC / 1 min (Type Test); 850 VDC / 1 sec (Routine Test per DIN EN 62368 & 60335) |
| Clearance / Creepage Distance | 1.0 mm / 1.2 mm |
| Control / Signal Features | 2-Wire Voltage-Regulated Operation (No Tachometer / PWM) |
| Termination Type | 2-Pin Integrated Flat Plug Connector |
| Terminal Blade Dimensions | 3.0 ±0.05 mm × 0.8 mm (0.118 × 0.031 in); Plug Recess: 11.5 ±0.5 mm (0.453 in) |
| Grounding Provision | M4 × 8 Torx Duo-Taptite Grounding Screw Provision (DIN 7500) |
| Outer Diameter | Ø 172.0 mm (6.77 in) |
| Housing Flat Height | 150.0 ±0.5 mm (5.91 in) |
| Total Axial Depth | 51.0 mm Nominal / 50.8 ±0.3 mm Drawing (2.00 in) |
| Flange Thickness | 8.5 ±0.5 mm (0.335 in) |
| Mounting Hole Pitch | 162.0 ±0.2 mm (6.38 in) |
| Mounting Hole Diameter | Ø 4.3 ±0.1 mm (0.169 in, 8× Flange Holes) |
| Mounting Screw & Torque Spec | ISO 4762 M4 Degreased (No Washer/Brace); Max. 260 Ncm Across Both Flanges |
| Weight | 0.760 kg (1.68 lbs) |
| Bearing Type | Dual Ball Bearing (Spring Preloaded Without Axial Clearance) |
| Housing / Frame Material | Metal |
| Impeller / Blade Material | Plastic |
| Direction of Rotation | Counterclockwise (Viewed Toward Rotor) |
| Installation Position | Any Shaft Orientation |
| EMC Standards | DIN EN 61000-4-2:2001-12 ESD Immunity (±4 kV Contact / ±8 kV Air, Criterion A) |
| Standards & Compliance | UL 507 (E38324), CSA C22.2 No. 113, VDE (EN 62368), CE, EAC |
| RoHS / Environmental Compliance | RoHS3 Compliant |
Applications
ebm-papst 6424 truncated-frame DC axial cooling fans are widely deployed across high-density power electronics, telecom rectifier shelves, variable frequency drives (VFDs), and uninterruptible power supply (UPS) battery cabinets. Their rigid metal wall-ring housing and plug-in terminal architecture simplify OEM chassis integration and drop-in MRO field replacement inside CNC machine tool control enclosures, servo amplifier racks, welding inverters, and solar power conversion systems. Multi-angle shaft mounting capability allows horizontal or vertical installation in forced-air heat sink ducts, industrial automation panels, and sheltered telecom equipment rooms.