6424 ebm-papst 24VDC 172x150x51mm DC Axial Cooling Fan

$115.53

ebm-papst 6424 24VDC 172x150x51mm DC axial fan, 3400RPM, 229.5CFM (390m³/h), 17W, featuring metal housing, ball bearings, plug terminals & auto-restart.

SKU: 6424 Category: Brand:

Description

ebm-papst 6424 (OEM Item No. 9295414301, specification code VWLG150XJLPS) is an industrial 6400 Series brushless DC tubeaxial fan engineered with a truncated round Ø172.0 × 150.0 × 51.0 mm (6.77 × 5.91 × 2.01 in) metal wall-ring frame and plastic impeller. Operating on a nominal 24 VDC supply across a wide 12 to 28 VDC voltage window, it runs at 3400 RPM (17 W, 710 mA at free air) to deliver 229.5 CFM (390.0 m³/h) of airflow over outlet struts and up to 0.755 in H₂O (188 Pa) of static pressure.

Designed for continuous industrial service in any shaft orientation, the unit incorporates spring-preloaded dual ball bearings rated for an L10 life of 75,000 hours at 40 °C (127,500 hours per IPC 9591) across an ambient temperature range of -20 °C to +72 °C (-4 °F to +161.6 °F). Integrated motor protection includes a reverse-polarity rectifying diode and locked-rotor auto-restart electronics, paired with an integrated 2-pin flat plug connector and UL 507, CSA, VDE, CE, and EAC certifications.

Key Features

  • High-Airflow Axial Output: Delivers 229.5 CFM (390.0 m³/h) free-air flow and 0.755 in H₂O (188 Pa) static pressure at 3400 RPM.
  • Wide 12–28 VDC Operation: Supports flexible voltage regulation from 1750 RPM (3.1 W) at 12 VDC up to 3850 RPM (26 W) at 28 VDC.
  • Rugged Metal Housing: Truncated Ø172 × 150 × 51 mm metal frame resists mechanical distortion up to 260 Ncm flange mounting torque.
  • Integrated Motor Protection: Built-in rectifying diode guards against reverse polarity alongside electronic locked-rotor current limiting and auto-restart.
  • Preloaded Ball Bearings: Spring-preloaded zero-axial-clearance ball bearing system achieves 75,000 hours L10 life at 40 °C in any mounting orientation.
  • Plug-In Termination & Approvals: Integrated 3.0 × 0.8 mm flat plug terminals with UL 507, VDE EN 62368, CSA, CE, and EAC compliance.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) 6424
OEM Item Number 9295414301 (Spec Code: VWLG150XJLPS)
Product Series 6400 Series
Product Category DC Axial Fans
Fan / Component Type DC Tubeaxial Cooling Fan with Truncated Wall Ring
Motor Design / Technology Brushless Electronically Commutated DC Motor
Phase & Supply Type DC
Rated Voltage 24 VDC
Operating Voltage Range 12 to 28 VDC
Speed (RPM) 3400 RPM ±10% (at 24 VDC, Free Air)
Speed at Min. Voltage 1750 RPM ±10% (at 12 VDC, Free Air)
Speed at Max. Voltage 3850 RPM ±10% (at 28 VDC, Free Air)
Power Rating 17 W ±25% (at 24 VDC, Free Air)
Power Input at Min. Voltage 3.1 W ±25% (at 12 VDC, Free Air)
Power Input at Max. Voltage 26 W ±20% (at 28 VDC, Free Air)
Rated Current 710 mA / 0.71 A ±25% (at 24 VDC, Free Air)
Current Draw at Min. Voltage 260 mA / 0.26 A ±25% (at 12 VDC, Free Air)
Current Draw at Max. Voltage 755 mA / 0.755 A ±20% (at 28 VDC, Free Air)
Inrush / Starting Current 4000 mA (4.0 A)
Locked-Rotor Current Approx. 4000 mA (at 24 VDC; Clock t3/t4: 1.4 s / 5.3 s typical)
Airflow (Max. Free Air) 229.5 CFM (390.0 m³/h)
Optimal Operating Duty Point 161.9 CFM (275.0 m³/h) at 0.245 in H₂O (61 Pa)
Max. Static Pressure 0.755 in H₂O (188 Pa)
Free-Air Sound Pressure Level 55.0 dB(A) (at 1 m Intake, Measured in Rubber Bands)
Sound Power Level (Optimal Point) 6.4 bel(A) / 64 dB(A) (per DIN 45635-38 / ISO 10302)
Airflow Direction Air Outlet Over Struts
Ingress Protection (IP) IP20 (Pollution Degree 1 per DIN EN 60664-1)
Operating Temperature -20 °C to +72 °C (-4 °F to +161.6 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Climatic Humidity Rating Constant Humid Heat, 14 Days (per DIN EN 60068-2-78)
Service Life L10 (at 40 °C) 75,000 Hours
Service Life L10 (at Max. Temp) 35,000 Hours (at 72 °C)
Service Life L10IPC 127,500 Hours (at 40 °C per IPC 9591)
Motor & Drive Protection Reverse Polarity Rectifying Diode (IF <= 10 mA), Locked-Rotor Protection with Auto-Restart
Electrical Protection Class Class III
Insulation Resistance > 10 MΩ (at 500 VDC for 1 min after 48h at 95% RH, 25 °C)
Dielectric Strength 500 VAC / 1 min (Type Test); 850 VDC / 1 sec (Routine Test per DIN EN 62368 & 60335)
Clearance / Creepage Distance 1.0 mm / 1.2 mm
Control / Signal Features 2-Wire Voltage-Regulated Operation (No Tachometer / PWM)
Termination Type 2-Pin Integrated Flat Plug Connector
Terminal Blade Dimensions 3.0 ±0.05 mm × 0.8 mm (0.118 × 0.031 in); Plug Recess: 11.5 ±0.5 mm (0.453 in)
Grounding Provision M4 × 8 Torx Duo-Taptite Grounding Screw Provision (DIN 7500)
Outer Diameter Ø 172.0 mm (6.77 in)
Housing Flat Height 150.0 ±0.5 mm (5.91 in)
Total Axial Depth 51.0 mm Nominal / 50.8 ±0.3 mm Drawing (2.00 in)
Flange Thickness 8.5 ±0.5 mm (0.335 in)
Mounting Hole Pitch 162.0 ±0.2 mm (6.38 in)
Mounting Hole Diameter Ø 4.3 ±0.1 mm (0.169 in, 8× Flange Holes)
Mounting Screw & Torque Spec ISO 4762 M4 Degreased (No Washer/Brace); Max. 260 Ncm Across Both Flanges
Weight 0.760 kg (1.68 lbs)
Bearing Type Dual Ball Bearing (Spring Preloaded Without Axial Clearance)
Housing / Frame Material Metal
Impeller / Blade Material Plastic
Direction of Rotation Counterclockwise (Viewed Toward Rotor)
Installation Position Any Shaft Orientation
EMC Standards DIN EN 61000-4-2:2001-12 ESD Immunity (±4 kV Contact / ±8 kV Air, Criterion A)
Standards & Compliance UL 507 (E38324), CSA C22.2 No. 113, VDE (EN 62368), CE, EAC
RoHS / Environmental Compliance RoHS3 Compliant

Applications

ebm-papst 6424 truncated-frame DC axial cooling fans are widely deployed across high-density power electronics, telecom rectifier shelves, variable frequency drives (VFDs), and uninterruptible power supply (UPS) battery cabinets. Their rigid metal wall-ring housing and plug-in terminal architecture simplify OEM chassis integration and drop-in MRO field replacement inside CNC machine tool control enclosures, servo amplifier racks, welding inverters, and solar power conversion systems. Multi-angle shaft mounting capability allows horizontal or vertical installation in forced-air heat sink ducts, industrial automation panels, and sheltered telecom equipment rooms.