Description
ebm-papst 6318/2TDH4P (also known as 63182TDH4P, OEM datasheet code 9295420021 / VWS0148XULDS) is a high-static-pressure 6300TD S-Force Series brushless tubeaxial cooling fan engineered with a rugged round metal wall-ring housing and precision plastic impeller measuring Ø172.0 × 51.0 mm (Ø6.77 × 2.01 in). Operating across a wide 36 to 72 VDC supply range around a 48 VDC nominal rating, it delivers 547.38 CFM (930 m³/h) of free-air volume and up to 5.264 in H₂O (1,310 Pa) of static pressure at 9,200 RPM while drawing 150 W (3,100 mA) at free air and 245 W at 9,360 RPM at its ErP optimum efficiency point.
Built for demanding continuous-duty industrial and railway thermal management, this unit integrates preload-spring ball bearings, a 1–20 kHz PWM control input, a 6-pulse/rev open-collector tachometer (/2), an internal 10 A / 125 V Littelfuse NANO2 fuse, P-channel FET reverse-polarity protection, under/overvoltage lockout, and locked-rotor auto-restart via a 4-wire 365 mm (14.37 in) harness.
Key Features
- High-Pressure S-Force Aerodynamics: Delivers 547.38 CFM (930 m³/h) free-air flow and 5.264 in H₂O (1,310 Pa) static pressure at 9,200 RPM.
- Wide-Range 48 VDC Drive Architecture: Operates seamlessly from 36 to 72 VDC with integrated 30 V undervoltage and 78 V overvoltage cutoff protection.
- Closed-Loop PWM & 6-Pulse Tachometer: Features a 1–20 kHz open-collector PWM speed input and a 6-pulse/rev (920 Hz) open-collector tachometer output.
- Comprehensive Electronic Safeguards: Equipped with P-CH FET reverse-polarity protection, a 10 A Littelfuse NANO2 internal fuse, and multi-stage auto-restart.
- Railway-Grade Mechanical Durability: Combines a die-cast metal housing, preload-spring ball bearings, and IEC 61373 Category 1 Class B vibration compliance.
- Extended Multi-Standard Certifications: Approved to UL 507, CSA C22.2 No. 113, VDE EN 60950, CE, CCC, EAC, and ErP Grade 40.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | 6318/2TDH4P |
| Alternate Part Number | 63182TDH4P |
| OEM Item Number | 9295420021 (Drawing / Spec Code: VWS0148XULDS) |
| Product Series | 6300TD (S-Force Series) |
| Product Category | DC Axial Fans |
| Fan / Component Type | Brushless DC Tubeaxial Fan with Round Wall-Ring Housing |
| Motor Design / Technology | Speed-Controlled Electronically Commutated DC Motor |
| Phase & Supply Type | DC Supply |
| Rated Voltage | 48 VDC |
| Operating Voltage Range | 36 to 72 VDC |
| Turn-On Voltage Window | > 32 VDC to < 76 VDC |
| Undervoltage / Overvoltage Cutoff | Turns Off at 78 VDC |
| Free-Air Speed (at 48 VDC) | 9,200 RPM ± 5% (at Δp = 0, 95% PWM) |
| Free-Air Speed (at 36 VDC Min. Voltage) | 8,300 RPM ± 7.5% (at Δp = 0, 95% PWM) |
| Free-Air Speed (at 72 VDC Max. Voltage) | 9,200 RPM ± 5% (at Δp = 0, 95% PWM) |
| ErP Optimum Speed (RPM) | 9,360 RPM (at Optimum Energy Efficiency Point) |
| Free-Air Power Input (at 48 VDC) | 150 W ± 10% (at Δp = 0, 95% PWM) |
| Free-Air Power Input (at 36 VDC Min. Voltage) | 106 W ± 10% (at Δp = 0, 95% PWM) |
| Free-Air Power Input (at 72 VDC Max. Voltage) | 160 W ± 10% (at Δp = 0, 95% PWM) |
| ErP Optimum Efficiency Power | 245 W (at Optimum Energy Efficiency Point) |
| Free-Air Current Draw (at 48 VDC) | 3,100 mA (3.10 A) ± 10% (at Δp = 0, 95% PWM) |
| Free-Air Current Draw (at 36 VDC Min. Voltage) | 3,000 mA (3.00 A) ± 10% (at Δp = 0, 95% PWM) |
| Free-Air Current Draw (at 72 VDC Max. Voltage) | 2,200 mA (2.20 A) ± 10% (at Δp = 0, 95% PWM) |
| Startup Delay Time | 2 s after Applying Supply Voltage |
| Airflow (Max. Free Air) | 547.38 CFM (930 m³/h / 15.50 m³/min) at 0 Pa (9,200 RPM) |
| Optimal Acoustic Operating Point | 535.61 CFM (910 m³/h) at 0.137 in H₂O (34 Pa) |
| Max. Static Pressure | 5.264 in H₂O (1,310 Pa / 133.58 mmH₂O) at 0 CFM |
| Free-Air Sound Pressure Level | 75.0 dB(A) (at 1 m Intake Distance, Free Air in Rubber Bands) |
| Sound Power Level (Optimal Point) | 8.6 bel(A) / 86.0 dB(A) (at 910 m³/h & 34 Pa per DIN 45635-38 / ISO 10302) |
| ErP Efficiency & Grade (EU 327/2011) | Overall Static Efficiency ηes = 42.9% (2015 Target: 29.8%), Efficiency Grade N = 40, Category A (Static), Specific Ratio = 1.00569 |
| Airflow Direction | Air Outlet Over Struts (Exhaust Over Struts) |
| Operating Temperature | -20 to +75 °C (-4 to +167 °F) |
| Storage Temperature | -40 to +80 °C (-40 to +176 °F) |
| Climatic & Humidity Compliance | Constant Humid Heat per DIN EN 60068-2-78 (14 Days); Pollution Degree 1 (DIN EN 60664-1) |
| Vibration & Shock Compliance | Sinusoidal 0.5 G (IEC 60068-2-6); Random 0.83 Grms in Use / 0.91 Grms Storage (IEC 60068-2-64); Bump 5 G in Use / 18 G Storage (IEC 60068-2-29); Shock 7 G / 18 ms (IEC 60068-2-27); Railroad IEC 61373 Category 1 Class B |
| Service Life L10 (at 40 °C) | 52,500 Hours |
| Service Life L10 (at Max. Temp 75 °C) | 20,000 Hours |
| Service Life L10IPC (at 40 °C) | 87,500 Hours (per IPC 9591) |
| Motor & Drive Protection | P-CH FET Reverse Polarity Protection (IF <= 5 mA), Locked-Rotor Auto-Restart, Undervoltage & Overvoltage Cutoff, Internal Fuse |
| Locked-Rotor Timing Cycle | t3 / t4 Typical: 1.5 s On / 10.0 s Off (First Off Time T4 = 3 s; Extended Downtime t5 = 40 s after 4 Start-Up Tests) |
| Internal Fuse Specification | Littelfuse NANO2 Very Fast-Acting 451/453 Series, 10 A / 125 V (Art. No. 0451010.MRL) |
| Electrical Protection Class | Class I |
| Insulation Resistance | > 10 MΩ at 500 VDC (after 48 h at 95% RH & 25 °C) |
| Dielectric Strength | 1,000 VAC for 1 min (Type Test) / 1,700 VDC for 1 s (Routine Test) per DIN EN 60950 & DIN EN 60335 |
| Clearance / Creepage Distance | 1.0 mm (0.039 in) / 1.5 mm (0.059 in) |
| Control / Signal Features | PWM Speed Control Input (Open Collector) & Tachometer Speed Sensor Output (/2 Open Collector) |
| PWM Control Frequency & Pull-Up | 1 kHz to 20 kHz (Typical: 2 kHz); Internal 4.7 kΩ Pull-Up Resistor to +5 V Reference (Transistor Req: VCE >= 12 V, Isink > 5 mA, VCEsat < 0.15 V) |
| PWM Speed Control Curve | 0–7% = Off (0 RPM); 7% Start-Up = 1,000 RPM; 7–10% = 1,000 RPM Min.; 10–90% = Linear Ramp; 90–100% (or Open Wire) = 9,200 RPM Max.; <= 5% = Turn-Off |
| Tachometer Output Specification | Type /2 Open Collector, 6 Pulses/Rev (920 Hz at 9,200 RPM), UBS <= 60 VDC, US Low <= 0.4 V (at 2 mA), Isink Max = 0.5 V/µs, Non-Isolated (External Pull-Up Ra Required) |
| Termination Type | 4 Single Lead Wires |
| Lead Wire Gauge & Spec | Power (+UB, -GND): AWG 18 (Ø2.2 mm / 0.087 in Insulation); Control/Signal (PWM, Tacho): AWG 22 (Ø1.7 mm / 0.067 in Insulation) |
| Cable / Lead Length | 365.0 ± 10.0 mm (14.37 ± 0.394 in) |
| Protective Tube Length | 10.0 ± 2.0 mm (0.394 ± 0.079 in) |
| Wiring Pinout / Connection | Wire 1 (Red): +UB (Supply Voltage) | Wire 2 (Blue): -GND (Ground) | Wire 3 (Violet): PWM Control Input | Wire 4 (White): Tacho Output |
| Outer Diameter (Ø) | 172.0 mm (6.772 in) |
| Total Axial Depth | 51.0 mm (2.008 in) |
| Mounting Screw Specification | ISO 4762 – M4 Degreased (without Additional Brace or Washer) |
| Grounding Screw Specification | Duo-Taptite M4 × 8 Torx per DIN 7500 |
| Max. Mounting Flange Torque | 600 Ncm (6.0 Nm / 53.1 lbf·in) at Wire Outlet Corner & Remaining Corners |
| Weight | 0.875 kg (1.929 lbs / 875 g) |
| Bearing Type | Ball Bearing System (Preload-Spring Clearance-Free Design) |
| Housing / Frame Material | Die-Cast Metal |
| Impeller / Blade Material | Fiberglass-Reinforced Plastic |
| Direction of Rotation | Counterclockwise (Looking at Rotor) |
| Installation Position | Any Shaft Orientation |
| Standards & Compliance | UL 507 (File E38324), CSA C22.2 No. 113, VDE EN 60950 (VDE 0805), CE, CCC (GB 12350), EAC, DIN EN ISO 5801 |
| RoHS / Environmental Compliance | RoHS3 Compliant |
Applications
ebm-papst 6318/2TDH4P tubeaxial cooling fans are engineered for high-density, high-impedance thermal management where substantial static pressure and closed-loop speed regulation are essential. Typical OEM and MRO deployments include telecom base station rectifiers, high-power variable frequency drives (VFDs), railway traction and onboard auxiliary converters, uninterruptible power supply (UPS) cabinets, solar string and central inverters, and densely populated industrial automation racks. Its railway-grade vibration resilience and metal wall-ring frame make it equally suited for heavy-duty CNC machine tool enclosures, laser power supplies, and sheltered power electronics cabinets.