614N/2GHH ebm-papst 24VDC 60x60x25mm DC Axial Cooling Fan

$51.08

ebm-papst 614N/2GHH (614N2GHH) 24VDC 60x60x25mm DC axial fan, 6850RPM, 31.78CFM (54m³/h), 3.6W, featuring open-collector tach output & locked-rotor auto-restart.

SKU: 614N/2GHH Category: Brand:

Description

ebm-papst 614N/2GHH (also known as 614N2GHH, OEM item number 9292206056 / specification VWC0060YUEBS) is a compact brushless DC tubeaxial cooling fan from the 600N series measuring 60.0 × 60.0 × 25.0 mm (2.362 × 2.362 × 0.984 in). Operating at a nominal 24.0 VDC across an 18.0 to 26.0 VDC supply range, it rotates at 6,850 RPM while drawing 3.6 W (150 mA) to deliver 31.78 CFM (54.0 m³/h) of free-air airflow and up to 0.538 in H₂O (134 Pa) of static pressure.

Constructed with a durable plastic housing and impeller supported by a precision Sintec sleeve bearing system, this unit handles ambient temperatures from -20 °C to +70 °C (-4 °F to +158 °F) in any shaft mounting orientation. It comes equipped with an integrated `/2` open-collector tachometer speed sensor (2 pulses/rev), rectifying diode reverse-polarity protection, locked-rotor auto-restart protection, and 310 mm (12.205 in) AWG 24 lead wires.

Key Features

  • High-Static Compact Airflow: Delivers 31.78 CFM (54.0 m³/h) free-air flow and 0.538 in H₂O (134 Pa) peak static pressure at 6,850 RPM.
  • Open-Collector Tachometer Output: Integrated /2 speed sensor outputs 2 pulses per revolution up to 28 VDC for real-time RPM telemetry.
  • Comprehensive Motor Protection: Features rectifying diode reverse-polarity protection and automatic locked-rotor restart with a 0.2 s / 1.1 s clock cycle.
  • Sintec Sleeve Bearing Reliability: Engineered for any shaft mounting position with an L10 service life of 60,000 hours at 40 °C (102,500 hours per IPC 9591).
  • Industrial Approvals & Wiring: Terminated with 310 mm AWG 24 color-coded leads and certified to UL 507, CSA C22.2 No. 113, VDE EN 60950, CE, and EAC.

Technical Specifications

Manufacturer ebm-papst
Manufacturer Part Number (MPN) 614N/2GHH
Alternate Part Number 614N2GHH
OEM Item Number 9292206056 (Spec Code: VWC0060YUEBS)
Product Series 600N / 600NG Series
Product Category DC Axial Fans
Fan / Component Type DC Tubeaxial Cooling Fan
Motor Design / Technology Brushless DC Electronically Commutated Motor
Phase & Supply Type DC
Rated Voltage 24.0 VDC
Operating Voltage Range 18.0 to 26.0 VDC
Free-Air Speed (at Nominal 24 VDC) 6,850 RPM (±10.0%)
Free-Air Speed (at Min. 18 VDC) 5,400 RPM (±15.0%)
Free-Air Speed (at Max. 26 VDC) 7,300 RPM (±15.0%)
Free-Air Power Input (at Nominal 24 VDC) 3.6 W (±12.5%)
Free-Air Power Input (at Min. 18 VDC) 1.8 W (±17.5%)
Free-Air Power Input (at Max. 26 VDC) 4.1 W (±17.5%)
Free-Air Current Draw (at Nominal 24 VDC) 150 mA (±12.5%)
Free-Air Current Draw (at Min. 18 VDC) 100 mA (±17.5%)
Free-Air Current Draw (at Max. 26 VDC) 157 mA (±17.5%)
Inrush / Starting Current 850 mA
Locked-Rotor Current (at Nominal 24 VDC) Approx. 850 mA
Max. Residual Current (at Nominal 24 VDC) <= 5 µA
Airflow (Max. Free Air) 31.78 CFM (54.0 m³/h / 0.90 m³/min)
Optimal Operating Point Duty Point 20.01 CFM (34.0 m³/h) at 0.133 in H₂O (33 Pa)
Max. Static Pressure 0.538 in H₂O (134 Pa)
Free-Air Sound Pressure Level (Intake, 1m) 42.0 dB(A)
Optimal Point Sound Power Level 5.6 bel(A) (56.0 dB(A) per DIN 45635-38 / ISO 10302)
Airflow Direction Air Outlet Over Struts
Operating Temperature -20 °C to +70 °C (-4 °F to +158 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Climatic & Humidity Rating Constant Humid Heat per DIN EN 60068-2-78 (14 Days); Pollution Degree 1 (DIN EN 60664-1)
Service Life L10 (at 40 °C) 60,000 Hours
Service Life L10 (at 60 °C) 37,500 Hours
Service Life L10 (at Max. Temp 70 °C) 30,000 Hours
Service Life L10IPC (at 40 °C per IPC 9591) 102,500 Hours
Motor & Drive Protection Rectifying Diode Reverse Polarity Protection, Locked-Rotor Auto-Restart (Typical Clock t3/t4: 0.2 s / 1.1 s)
Electrical Protection Class Class III
Insulation Resistance > 10 MΩ (Measured at 500 VDC for 1 min after 48h at 95% RH, 25 °C)
Clearance / Creepage Distance 1.0 mm / 1.2 mm (0.039 in / 0.047 in)
Control / Signal Features Speed Sensor (Tachometer Output, /2 Open Collector, Non-Isolated)
Tachometer Operating Voltage (UBS) <= 28 VDC (External Pull-Up Resistor Ra Required)
Tachometer Output Logic Levels Low (US low): <= 0.4 V (at Isink = 2 mA); High (US high): 28 V (at Isource = 0 mA)
Tachometer Max. Sink Current & Slew Rate = 0.5 V/µs Slew Rate
Tachometer Pulse Frequency 2 Pulses per Revolution ((2 × n) / 60 Hz)
Termination Type 3 Lead Wires (Tin-Plated Ends)
Lead Wire Gauge & Spec AWG 24 (Insulation Outer Diameter: 1.50 mm / 0.059 in)
Cable / Lead Length 310.0 ±10.0 mm (12.205 ±0.394 in)
Wiring Pinout / Connection Wire 1 (Red): +UB (+24 VDC); Wire 2 (Blue): -GND; Wire 3 (White): Tacho Output
Dimensions (L × H × D) 60.0 × 60.0 × 25.0 mm (2.362 × 2.362 × 0.984 in)
Mounting Hole Pitch 50.0 ±0.2 mm (1.969 ±0.008 in)
Mounting Hole Diameter Ø 3.7 ±0.15 mm (0.146 ±0.006 in)
Recommended Mounting Screw & Torque ISO 4762 M3 Degreased Screw; Max. Torque: 20 Ncm (Wire Outlet Corner), 40 Ncm (Remaining Corners)
Weight 0.066 kg (0.146 lbs / 66 g)
Bearing Type Sintec Sleeve Bearing
Housing / Frame Material Plastic
Impeller / Blade Material Plastic
Direction of Rotation Clockwise (Looking at Rotor)
Installation Position Any Shaft Orientation
Standards & Compliance UL 507 (File E38324), CSA C22.2 No. 113, VDE (EN 60950 / VDE 0805), CE, EAC
RoHS / Environmental Compliance RoHS3 Compliant

Applications

The ebm-papst 614N/2GHH DC axial cooling fan is engineered for high-density electronic enclosures and compact industrial subsystems that require forced-air thermal dissipation and continuous speed monitoring. Typical installations include 1U and 2U rackmount servers, PoE network switches, telecommunications rectifiers, optical transceiver chassis, and embedded industrial PCs (IPCs). It is also widely deployed by OEMs and MRO technicians inside PLC automation racks, compact variable frequency drives (VFDs), and laboratory diagnostic analyzers operating in sheltered, climate-controlled environments.