Description
ebm-papst 4656ZH (OEM Specification 9244014870) is an industrial 4000Z Series tubeaxial cooling fan built with an all-metal housing and metal impeller in a standard 119.0 x 119.0 x 38.0 mm (4.685 x 4.685 x 1.496 in) square frame. Driven by an impedance-protected shaded-pole external rotor motor with precision ball bearings, this dual-frequency unit operates on 230 VAC (50 / 60 Hz) to deliver 89.46 CFM (152.0 m³/h) at 2650 RPM (19.0 W, 115 mA) on 50 Hz and 105.94 CFM (180.0 m³/h) at 3100 RPM (17.0 W, 100 mA) on 60 Hz, achieving maximum static pressures up to 0.281 in H₂O (70 Pa) and 0.321 in H₂O (80 Pa) respectively.
Engineered for demanding thermal environments from -40 °C to +75 °C (50 Hz) and up to +85 °C (60 Hz), it integrates a galvanically isolated Special-Tacho speed monitoring interface (reinforced with 3750 VAC / 4200 VAC motor-to-tacho dielectric isolation) and a 310.0 mm (12.20 in) 22 AWG plug harness.
Key Features
- Dual-Frequency Aerodynamic Performance: Delivers 89.46 CFM (152.0 m³/h) at 50 Hz and 105.94 CFM (180.0 m³/h) at 60 Hz.
- Galvanically Isolated Special-Tacho Output: Features an isolated 4.5–24 VDC tachometer circuit with 4200 VAC routine dielectric isolation from the AC motor.
- Rugged All-Metal Construction: Combines a durable metal frame and metal impeller balanced to grade G 2.5 for low-vibration continuous duty.
- Wide-Temperature Ball Bearing System: Operates reliably from -40 °C up to +85 °C (60 Hz) with an L10 life of 40,000 hours at 40 °C.
- Impedance Locked-Rotor Protection: Class F insulated shaded-pole motor prevents thermal overload during stall conditions and meets UL, CSA, VDE, and CCC standards.
Technical Specifications
| Manufacturer | ebm-papst |
|---|---|
| Manufacturer Part Number (MPN) | 4656ZH |
| OEM Item Number | 9244014870 (ebm-papst Product Specification) |
| Product Series | 4000Z |
| Product Category | AC Axial Fans |
| Fan / Component Type | AC Tubeaxial Cooling Fan |
| Motor Design / Technology | Shaded-Pole External Rotor Motor |
| Phase & Supply Type | 1-Phase AC (1~) |
| Rated Voltage | 230 VAC |
| Operating Voltage Range | 207 to 243.8 VAC (-10% to +6%) |
| Frequency | 50 / 60 Hz |
| Free-Air Speed (RPM) | 2650 RPM ±3% (50 Hz) / 3100 RPM ±3% (60 Hz) |
| Free-Air Power Input | 19.0 W ±10% (50 Hz) / 17.0 W ±10% (60 Hz) |
| Free-Air Current Draw | 115 mA ±10% (50 Hz) / 100 mA ±10% (60 Hz) |
| Operating Mode / Duty Cycle | Continuous Duty (S1) |
| Airflow (Max. Free Air) | 89.46 CFM / 152.0 m³/h (50 Hz) | 105.94 CFM / 180.0 m³/h (60 Hz) |
| Optimal Operating Duty Point | 76.52 CFM (130.0 m³/h) at 0.060 in H₂O (15 Pa) (50 Hz) / 87.11 CFM (148.0 m³/h) at 0.080 in H₂O (20 Pa) (60 Hz) |
| Max. Static Pressure | 0.281 in H₂O / 70 Pa (50 Hz) | 0.321 in H₂O / 80 Pa (60 Hz) |
| Free-Air Sound Pressure Level | 37.0 dB(A) (50 Hz) / 42.0 dB(A) (60 Hz) (at 1 m intake) |
| Sound Power Level (Optimal Operating Point) | 5.1 bel(A) / 51 dB(A) (50 Hz) | 5.5 bel(A) / 55 dB(A) (60 Hz) |
| Airflow Direction | Air Outlet Over Struts |
| Pollution Degree | Pollution Degree 1 (DIN EN 60664-1) |
| Operating Temperature | -40 to +75 °C (-40 to +167 °F) at 50 Hz / -40 to +85 °C (-40 to +185 °F) at 60 Hz |
| Storage Temperature | -40 to +100 °C (-40 to +212 °F) |
| Humidity Resistance | Constant Humid Heat per DIN EN 60068-2-78 (14 Days) |
| Service Life L10 (at 40 °C) | 37,500 Hours (50 Hz) / 40,000 Hours (60 Hz) |
| Service Life L10 (at Max. Temp) | 17,500 Hours at 75 °C (50 Hz) / 15,000 Hours at 85 °C (60 Hz) |
| Motor & Drive Protection | Impedance Locked-Rotor Protection |
| Electrical Protection Class | Class I |
| Insulation Class | Class F |
| Insulation Resistance | > 10 MΩ at 500 VDC (Motor to Ground U1) / > 20 MΩ at 1000 VDC (Tacho to Motor U3) |
| Dielectric Strength (Motor to Ground U1) | 1500 VAC for 1 Min (Type Test) / 1500 VAC for 1 Sec (Routine Test) |
| Dielectric Strength (Tacho to Ground U2) | 500 VAC for 1 Min (Type Test) / 600 VAC for 1 Sec (Routine Test) |
| Dielectric Strength (Tacho to Motor U3) | 3750 VAC for 1 Min (Type Test) / 4200 VAC for 1 Sec (Routine Test) |
| Clearance / Creepage Distance | 2.0 mm (0.079 in) / 1.8 mm (0.071 in) |
| Control / Signal Features | Galvanically Isolated Special-Tacho Speed Signal Output (External Pull-Up Resistor Ra Required) |
| Tachometer Operating Voltage Range | 4.5 to 24 VDC (Nominal UBS < 30 VDC) |
| Tachometer Operating Current | <= 10 mA (Max. Sink Current <= 20 mA) |
| Tachometer Signal Levels | Low <= 0.4 V (at 15 mA Sink) / High 30 V (at 0 mA Source) |
| Tachometer Frequency & Pulse Time | f = n / 50 (Pulse Time: 0.28 s Min. to 1.5 s Max.) |
| Termination Type | Plug Connector with Lead Wires |
| Lead Wire Gauge & Spec | 22 AWG (Insulation Diameter: 1.20 mm / 0.047 in) |
| Cable / Lead Length | 310.0 ± 10.0 mm (12.20 ± 0.39 in) |
| Wiring Pinout / Connection | Pin 3 Violet: -GND Tacho | Pin 4 Red: +UB Tacho | Pin 5 White: Tacho Signal Output |
| Dimensions (L × H × D) | 119.0 x 119.0 x 38.0 mm (4.685 x 4.685 x 1.496 in) |
| Motor Stator / Hub Dimensions | Ø 40.0 mm x 14.0 mm H (Ø 1.575 in x 0.551 in H) |
| Mounting Screw Size | ISO 4762 M4 Degreased (Without Additional Brace or Washer) |
| Max. Mounting Torque | Wire Outlet Corner: 120 Ncm (10.62 in-lbs) / Remaining Corners: 350 Ncm (30.98 in-lbs) |
| Weight | 0.540 kg (1.19 lbs) |
| Bearing Type | Ball Bearing |
| Balance Quality | G 2.5 |
| Housing / Scroll / Frame Material | Metal |
| Impeller / Blade Material | Metal |
| Direction of Rotation | Clockwise (Looking at Rotor) |
| Installation Position | Any Shaft Orientation |
| Standards & Compliance | CE, UL 507, CSA C22.2 No. 113, VDE (EN 60950), CCC (GB 12350), EAC |
| RoHS / Environmental Compliance | RoHS3 Compliant |
Applications
ebm-papst 4656ZH AC tubeaxial cooling fans are deployed across industrial automation cabinets, PLC control racks, and variable frequency drive (VFD) enclosures requiring continuous forced-air heat dissipation and closed-loop rotation monitoring. Their rugged all-metal construction and wide-temperature ball bearing system make them ideal for CNC machine tool controllers, uninterruptible power supply (UPS) battery banks, and telecommunications power rectifiers operating in elevated ambient temperatures. Additionally, the galvanically isolated tachometer output supports direct integration with host supervisory boards in medical diagnostic equipment, commercial printing machinery, and power electronics switchgear.